A vector network analyzer-based near field scanner for MM-wave and THz receivers

Author(s):  
Kristina Davis ◽  
Chris Groppi ◽  
Hamdi Mani ◽  
Caleb Wheeler ◽  
Chris Walker
2021 ◽  
Vol 11 (12) ◽  
pp. 5415
Author(s):  
Aleksandr Gorst ◽  
Kseniya Zavyalova ◽  
Aleksandr Mironchev ◽  
Andrey Zapasnoy ◽  
Andrey Klokov

The article investigates the near-field probe of a special design to account for changes in glucose concentration. The probe is designed in such a way that it emits radiation in both directions from its plane. In this paper, it was proposed to modernize this design and consider the unidirectional emission of the probe in order to maximize the signal and reduce energy loss. We have done extensive research for both bidirectional and unidirectional probe designs. Numerical simulations and field experiments were carried out to determine different concentrations of glucose (0, 4, 5.3, 7.5 mmol/L). Numerical modeling of a unidirectional probe showed that the interaction of radiation generated by such a probe with a multilayer structure simulating a human hand showed a better result and high sensitivity compared to a bidirectional probe. Further, based on the simulation results, a phantom (physical model) of a human hand was recreated from layers with dielectric properties as close as possible to the properties of materials during simulation. The probe was constructed from a copper tube and matched both the geometric and physical parameters of the model. The experimental measurement was carried out using a vector network analyzer in the frequency range 2–10 GHz. The experimental measurement was carried out using a vector network analyzer in the frequency range 2–10 GHz for the unidirectional and bidirectional probes. Further, the results of the experiment were compared with the results of numerical simulation. According to the results of multiple experiments, it was found that the average deviation between the concentrations was 2 dB for a unidirectional probe and 0.4 dB for a bidirectional probe. Thus, the sensitivity of the unidirectional probe was 1.5 dB/(mmol/L) for the bidirectional one 0.3 dB/(mmol/L). Thus, the improved design of the near-field probe can be used to record glucose concentrations.


2020 ◽  
Vol 11 (1) ◽  
pp. 217-222
Author(s):  
Haryo Dwi Prananto ◽  
Priyo Wibowo ◽  
Tyas Ari Wahyu Wijanarko ◽  
Wuwus Ardiatna ◽  
R. Harry Arjadi

Pada pengujian kompatibilitas elektromagnetik khususnya pada pengukuran near field, pengukuran medan magnet sangat diperlukan. Salah satu alat pengukuran yang digunakan adalah magnetic loop probe.  Penelitian ini dilakukan untuk membandingkan loop probe pada jumlah sisi geometrinya, dan belum ada referensi yang membahas tentang topik ini. Magnetic loop probe didesain dalam tujuh bentuk geometri yaitu bentuk segi 3 (ada dua model), segi 4, segi 6, segi 8, segi 10, dan segi tak hingga (lingkaran) dimana parameter keliling geometrinya sama. Magnetic loop probe didesain dengan menggunakan perhitungan sebagai small loop antenna Karateristik kelima desain probe dianalisis dengan mengukur S21 sebagai sensitivitas menggunakan Vector Network Analyzer. Karateristik bentuk probe maupun gain dan sensitivitasnya  dibahas dalam makalah ini.


Author(s):  
Joel Carpenter ◽  
Benjamin J. Eggleton ◽  
Jochen Schröder

2021 ◽  
Vol 69 (1) ◽  
pp. 874-886
Author(s):  
Alberto Maria Angelotti ◽  
Gian Piero Gibiino ◽  
Troels S. Nielsen ◽  
Dominique Schreurs ◽  
Alberto Santarelli

Sign in / Sign up

Export Citation Format

Share Document