Novel Frame Synchronization System for RGB-LED Parallel Transmission employing BPPM Format

Author(s):  
Jyo Matsushima ◽  
Tomohiro Kiguchi ◽  
Hiromasa Habuchi
Author(s):  
G. N. Maltsev ◽  
A. V. Evteev

Introduction: Radio information transmission systems with noise-like phase-shift keyed signals based on pseudo-random sequences have potential noise immunity provided by accurately tracking the delay of the received signal in the correlation receiver. When working with moving objects, the delay of the received signal varies continuously, and the reception quality for noise-like phase-shifted signals highly depends on the synchronization system operation and on the accuracy of estimating the received signal delay by the tracking system. To ensure the required signal reception quality, it is necessary to provide an informed choice of tracking system parameters, taking into account their effects, which are the random and systematic components of the delay tracking error, on the selected noise immunity indicator.Purpose: Analyzing how the errors in tracking the delay of a received phase-shift keyed signal based on a pseudorandom sequence by the synchronization system of a radio information transmission system can affect the probability of erroneous reception of an information symbol.Results: The calculation method was used to obtain families of dependencies of the probability of erroneous reception of an information symbol on the signal-noise ratio (SNR), and the values of the random and systematic components of the delay tracking error which are normalized to the capture band of the correlation receiver. It has been shown that at a fixed SNR, the values of the random and systematic components of the delay tracking error are critical for the erroneous reception probability. In all the cases discussed, all the dependencies are characterized by a slow change of the erroneous reception probability while the synchronization errors within the area of small SNR have fixed values. As the SNR value grows, the erroneous reception probability rapidly drops. To ensure the specified signal reception quality and the reliability of the selection of information symbols and messages in a radio information transmission system with noise-like phase-manipulated signals, its synchronization system requires a joint selection of the tracking system parameters, taking into account the limitations imposed by the operating conditions and technical implementation features.Practical relevance: The obtained results can be used in noise immunity analysis of radio information transmission systems with noise-like phase-shift keyed signals in a wide range of communication conditions, and in providing technical solutions for synchronization systems ensuring the required quality of signal reception.


Author(s):  
Nishant Kothari ◽  
Bhavesh R. Bhalja ◽  
Vivek Pandya ◽  
Pushkar Tripathi ◽  
Soumitri Jena

AbstractThis paper presents a phasor-distance based faulty phase detection and fault classification technique for parallel transmission lines. Detection and classification of faulty phase(s) have been carried out by deriving indices from the change in phasor values of current with a distance of one cycle. The derived indices have zero values during normal operating conditions whereas the index corresponding to the faulty phase exceeds the pre-defined threshold in case of occurrence of a fault. A separate ground detection algorithm has been utilized for the identification of involvement of ground in a faulty situation. The performance of the proposed technique has been evaluated for intra-circuit, inter-circuit and simultaneous faults with wide variations in system and fault conditions. The suggested technique has been evaluated for over 23,000 diversified simulated fault cases as well as 14 recorded real fault events. The performance of the proposed technique remains consistent under Current Transformer (CT) saturation as well as different amount and direction of power flow. Moreover, suitability to different power system network has also been studied. Also, faults having fault current less than pre-fault conditions have been detected accurately. The results obtained suggest that it is able to detect faulty phases as well as classify faults within quarter-cycle from the inception of fault with impeccable accuracy. Besides, as modern digital relays have been already equipped with phasor computation facility, phasor-based technique can be easily incorporated with relative ease. At last, a comparative evaluation suggests its superiority in terms of fault classification accuracy, fault detection time, diversify fault scenarios and computational requirement among other existing techniques.


Sign in / Sign up

Export Citation Format

Share Document