A low cost approach to calibrate on-chip thermal sensors

Author(s):  
Krishna Bharath ◽  
Chunhua Yao ◽  
Nam Sung Kim ◽  
Parameswaran Ramanathan ◽  
Kewal K. Saluja
Sensors ◽  
2019 ◽  
Vol 19 (5) ◽  
pp. 1178 ◽  
Author(s):  
Jorge Prada ◽  
Christina Cordes ◽  
Carsten Harms ◽  
Walter Lang

This contribution outlines the design and manufacturing of a microfluidic device implemented as a biosensor for retrieval and detection of bacteria RNA. The device is fully made of Cyclo-Olefin Copolymer (COC), which features low auto-fluorescence, biocompatibility and manufacturability by hot-embossing. The RNA retrieval was carried on after bacteria heat-lysis by an on-chip micro-heater, whose function was characterized at different working parameters. Carbon resistive temperature sensors were tested, characterized and printed on the biochip sealing film to monitor the heating process. Off-chip and on-chip processed RNA were hybridized with capture probes on the reaction chamber surface and identification was achieved by detection of fluorescence tags. The application of the mentioned techniques and materials proved to allow the development of low-cost, disposable albeit multi-functional microfluidic system, performing heating, temperature sensing and chemical reaction processes in the same device. By proving its effectiveness, this device contributes a reference to show the integration potential of fully thermoplastic devices in biosensor systems.


2004 ◽  
Vol 50 (1) ◽  
pp. 185-191 ◽  
Author(s):  
J.E. Ebdon ◽  
J.L. Wallis ◽  
H.D. Taylor

Antibiotic resistance profiling (ARP) is a potentially useful method for distinguishing faecal bacteria according to host source. This phenotypic approach has cost benefits over genotypic methods, but existing protocols are time-consuming and manual data handling is open to human error. A simplified, low-cost approach to the ARP technique was developed that used automated data recording techniques combined with simple statistical analyses to compare isolates of the genus Enterococcus from various faecal sources. An initial battery of 21 antibiotics (at up to four concentrations) was chosen for source discrimination. Images of growth or non-growth in microplate wells were stored as bitmaps and converted to binary data to form a database of known antibiotic resistance profiles. Discriminant function analysis (DFA) showed that the average rate of isolates correctly classified by the database (wastewater vs non-wastewater) was 86%. Once the more discriminating antibiotics and their concentrations had been identified, it was possible to reduce the number of tests from 80 to 18 whilst increasing the number of correctly classified human isolates. ARP could offer a low-cost and rapid means of identifying sources of faecal pollution. As such, the technique may be of particular benefit to developing countries, where water quality may have a significant impact on health and where cost is a major factor when choosing environmental management technology.


2019 ◽  
Vol 4 (3) ◽  
pp. 580-585 ◽  
Author(s):  
Bineh G. Ndefru ◽  
Bryan S. Ringstrand ◽  
Sokhna I.-Y. Diouf ◽  
Sönke Seifert ◽  
Juan H. Leal ◽  
...  

Combining bottom-up self-assembly with top-down 3D photoprinting affords a low cost approach for the introduction of nanoscale features into a build with low resolution features.


2011 ◽  
Vol 59 (4) ◽  
pp. 1155-1163 ◽  
Author(s):  
Mohamed H. Awida ◽  
Shady H. Suleiman ◽  
Aly E. Fathy

Sign in / Sign up

Export Citation Format

Share Document