microfluidic system
Recently Published Documents


TOTAL DOCUMENTS

1557
(FIVE YEARS 449)

H-INDEX

67
(FIVE YEARS 12)

2022 ◽  
Author(s):  
Tamás Vermes ◽  
Mark Kielpinski ◽  
Thomas Henkel ◽  
Miquel A. Pericàs ◽  
Esther Alza ◽  
...  

A fully automated microfluidic system was developed to screen for novel anti-HBV capsid assembly modulators. High-resolution dose–response curves were generated using convection-dominated Taylor–Aris dispersion of the screening compounds.


Lab on a Chip ◽  
2022 ◽  
Author(s):  
Hyungkook Jeon ◽  
Taehong Kwon ◽  
Junghyo Yoon ◽  
Jongyoon Han

Inertial microfluidics has enabled many impactful high throughput applications. However, devices fabricated in soft elastomer (i.e., polydimethylsiloxane (PDMS)) suffer reliability issues due to significant deformation generated by the high pressure...


Lab on a Chip ◽  
2022 ◽  
Author(s):  
Rishabh Gandotra ◽  
Hung-Bin Wu ◽  
Priya Gopinathan ◽  
Yi-Cheng Tsai ◽  
Feng-Chih Kuo ◽  
...  

Periprosthetic joint infections (PJI) arising from joint arthroplasty are dreadful, yet difficult to diagnose in subtle cases. Definite diagnosis requires microbiological culture to confirm the causative pathogens. However, up to...


Micromachines ◽  
2021 ◽  
Vol 13 (1) ◽  
pp. 30
Author(s):  
Mazlee Bin Mazalan ◽  
Anas Mohd Noor ◽  
Yufridin Wahab ◽  
Shuhaida Yahud ◽  
Wan Safwani Wan Kamarul Zaman

Acoustics have a wide range of uses, from noise-cancelling to ultrasonic imaging. There has been a surge in interest in developing acoustic-based approaches for biological and biomedical applications in the last decade. This review focused on the application of surface acoustic waves (SAW) based on interdigital transducers (IDT) for live-cell investigations, such as cell manipulation, cell separation, cell seeding, cell migration, cell characteristics, and cell behaviours. The approach is also known as acoustofluidic, because the SAW device is coupled with a microfluidic system that contains live cells. This article provides an overview of several forms of IDT of SAW devices on recently used cells. Conclusively, a brief viewpoint and overview of the future application of SAW techniques in live-cell investigations were presented.


Micromachines ◽  
2021 ◽  
Vol 13 (1) ◽  
pp. 20
Author(s):  
Nikita Sitkov ◽  
Tatiana Zimina ◽  
Alexey Kolobov ◽  
Evgeny Sevostyanov ◽  
Valentina Trushlyakova ◽  
...  

A study of the peculiarities and a comparative analysis of the technologies used for the fabrication of elements of novel hybrid microfluidic biochips for express biomedical analysis have been carried out. The biochips were designed with an incorporated microfluidic system, which enabled an accumulation of the target compounds in a biological fluid to be achieved, thus increasing the biochip system’s sensitivity and even implementing a label-free design of the detection unit. The multilevel process of manufacturing a microfluidic system of a given topology for label-free fluorometric detection of protein structures is presented. The technological process included the chemical modification of the working surface of glass substrates by silanization using (3-aminopropyl) trimethoxysilane (APTMS), formation of the microchannels, for which SU-8 technologies and a last generation dry film photoresist were studied and compared. The solid-state phosphor layers were deposited using three methods: drop application; airbrushing; and mechanical spraying onto the adhesive surface. The processes of sealing the system, installing input ports, and packaging using micro-assembly technologies are described. The technological process has been optimized and the biochip was implemented and tested. The presented system can be used to design novel high-performance diagnostic tools that implement the function of express detection of protein markers of diseases and create low-power multimodal, highly intelligent portable analytical decision-making systems in medicine.


2021 ◽  
Vol 8 ◽  
Author(s):  
Alicia K. Aquino ◽  
Zachary A. Manzer ◽  
Susan Daniel ◽  
Matthew P. DeLisa

In recent years, cell-free synthetic glycobiology technologies have emerged that enable production and remodeling of glycoproteins outside the confines of the cell. However, many of these systems combine multiple synthesis steps into one pot where there can be competing reactions and side products that ultimately lead to low yield of the desired product. In this work, we describe a microfluidic platform that integrates cell-free protein synthesis, glycosylation, and purification of a model glycoprotein in separate compartments where each step can be individually optimized. Microfluidics offer advantages such as reaction compartmentalization, tunable residence time, the ability to tether enzymes for reuse, and the potential for continuous manufacturing. Moreover, it affords an opportunity for spatiotemporal control of glycosylation reactions that is difficult to achieve with existing cell-based and cell-free glycosylation systems. In this work, we demonstrate a flow-based glycoprotein synthesis system that promotes enhanced cell-free protein synthesis, efficient protein glycosylation with an immobilized oligosaccharyltransferase, and enrichment of the protein product from cell-free lysate. Overall, this work represents a first-in-kind glycosylation-on-a-chip prototype that could find use as a laboratory tool for mechanistic dissection of the protein glycosylation process as well as a biomanufacturing platform for small batch, decentralized glycoprotein production.


Author(s):  
Sara Tombelli ◽  
Cosimo Trono ◽  
Simone Berneschi ◽  
Chiara Berrettoni ◽  
Ambra Giannetti ◽  
...  

AbstractThe present paper describes a compact point of care (POC) optical device for therapeutic drug monitoring (TDM). The core of the device is a disposable plastic chip where an immunoassay for the determination of immunosuppressants takes place. The chip is designed in order to have ten parallel microchannels allowing the simultaneous detection of more than one analyte with replicate measurements. The device is equipped with a microfluidic system, which provides sample mixing with the necessary chemicals and pumping samples, reagents and buffers into the measurement chip, and with integrated thin film amorphous silicon photodiodes for the fluorescence detection. Submicrometric fluorescent magnetic particles are used as support in the immunoassay in order to improve the efficiency of the assay. In particular, the magnetic feature is used to concentrate the antibody onto the sensing layer leading to a much faster implementation of the assay, while the fluorescent feature is used to increase the optical signal leading to a larger optical dynamic change and consequently a better sensitivity and a lower limit of detection. The design and development of the whole integrated optical device are here illustrated. In addition, detection of mycophenolic acid and cyclosporine A in spiked solutions and in microdialysate samples from patient blood with the implemented device are reported. Graphical abstract


Sign in / Sign up

Export Citation Format

Share Document