scholarly journals Reliability Analysis of a High-Efficiency SiC Three-Phase Inverter

Author(s):  
Juan Colmenares ◽  
Diane-Perle Sadik ◽  
Patrik Hilber ◽  
Hans-Peter Nee
2015 ◽  
Vol 51 (6) ◽  
pp. 4664-4676 ◽  
Author(s):  
Juan Colmenares ◽  
Dimosthenis Peftitsis ◽  
Jacek Rabkowski ◽  
Diane-Perle Sadik ◽  
Georg Tolstoy ◽  
...  

Author(s):  
Essam Hendawi ◽  
Sherif Zaid

<span lang="EN-US">One of the most important and common parts of the modern power systems is the grid-connected photovoltaic (PV) systems. Recently, these systems have gotten a big revolution due to the introduction of the transformerless inverters. It has the merits of small size, low cost, and high efficiency. However, transformerless inverters has a general safety problem related to the earth leakage current. Various researches were directed toward evolving their performance and diminishing the leakage current to the standard limits. This article proposes an application of the H7 controller to a PV powered grid-tied three phase transformerless inverter. The transformerless inverter is linked with the grid through a boost converter. The boost converter inductance is rearranged and divided to reduce the earth leakage current of the system. simulations are carried out for the proposed H7 PV grid-tied system and for a system that uses the conventional three phase inverter. The simulation results show that the H7 inverter provides lower leakage current, higher efficiency, and lower total harmonic distortion (THD) compared to the conventional three phase inverter.</span>


2000 ◽  
Vol 120 (3) ◽  
pp. 417-422 ◽  
Author(s):  
Shin-ichiro Nagai ◽  
Shinji Sato ◽  
Youichi Ito ◽  
Koichi Morita

Author(s):  
Taoufik Laagoubi ◽  
Mostafa Bouzi ◽  
Mohamed Benchagra

Two fuzzy logic controllers are proposed in this paper to control a three phase inverter for grid connected photovoltaic system. The first controller was used to predict the DC voltage that allows the three phase inverter to track the maximum power point of photovoltaic array under different environmental conditions such as irradiances and temperature. The second was used to control the active power and reactive power injected into the grid in order to inject the maximum active power produced by photovoltaic systems into grid with high efficiency and low total harmonic distortion using the same three phase inverter. The system components are photovoltaic array, DC link voltage, three-phase inverter, inverter control, LC filter, transformer and grid.  To verify the effectivnesse of the introdueced system, modeling and simulation are verified in Matlab/Simulink due to its frequent use and its effectiveness.


Sign in / Sign up

Export Citation Format

Share Document