A microfluidic device for antimicrobial susceptibility testing of combined antibiotics by using broth dilution method

Author(s):  
Wen-Bin Lee ◽  
Wen-Hsin Chang ◽  
Huey-Ling You ◽  
Mel S. Lee ◽  
Gwo-Bin Lee
2017 ◽  
Vol 87 ◽  
pp. 669-678 ◽  
Author(s):  
Wen-Bin Lee ◽  
Chien-Yu Fu ◽  
Wen-Hsin Chang ◽  
Huey-Ling You ◽  
Chih-Hung Wang ◽  
...  

Antibiotics ◽  
2021 ◽  
Vol 10 (8) ◽  
pp. 975
Author(s):  
Florian Baquer ◽  
Asma Ali Sawan ◽  
Michel Auzou ◽  
Antoine Grillon ◽  
Benoît Jaulhac ◽  
...  

Antimicrobial susceptibility testing of anaerobes is challenging. Because MIC determination is recommended by both CLSI and EUCAST, commercial broth microdilution and diffusion strip tests have been developed. The reliability of broth microdilution methods has not been assessed yet using the agar dilution reference method. In this work, we evaluated two broth microdilution kits (MICRONAUT-S Anaerobes® MIC and Sensititre Anaerobe MIC®) and one gradient diffusion strip method (Liofilchem®) for antimicrobial susceptibility testing of 47 Clostridiales isolates (Clostridium, Clostridioides and Hungatella species) using the agar dilution method as a reference. The evaluation focused on comparing six antimicrobial molecules available in both microdilution kits. Analytical performances were evaluated according to the Food and Drug Administration (FDA) recommendations. Essential agreements (EA) and categorical agreements (CA) varied greatly according to the molecule and the evaluated method. Vancomycin had values of essential and categorical agreements above 90% for the three methods. The CA fulfilled the FDA criteria for three major molecules in the treatment of Gram-positive anaerobic infections (metronidazole, piperacillin/tazobactam and vancomycin). The highest rate of error was observed for clindamycin. Multicenter studies are needed to further validate these results.


2020 ◽  
Vol 86 (9) ◽  
Author(s):  
Luyao Ma ◽  
Marlen Petersen ◽  
Xiaonan Lu

ABSTRACT Campylobacter spp. have been recognized as major foodborne pathogens worldwide. An increasing frequency of antibiotic-resistant pathogens, including Campylobacter spp., have been identified to transmit from food products to humans and cause severe threats to public health. To better mitigate the antibiotic resistance crisis, rapid detection methods are required to provide timely antimicrobial resistance surveillance data for agri-food systems. Herein, we developed a polymer-based microfluidic device for the identification and antimicrobial susceptibility testing (AST) of Campylobacter spp. An array of bacterial incubation chambers were created in the microfluidic device, where chromogenic medium and antibiotics were loaded. The growth of Campylobacter spp. was visualized by color change due to chromogenic reactions. This platform achieved 100% specificity for Campylobacter identification. Sensitive detection of multiple Campylobacter species (C. jejuni, C. coli, and C. lari) was obtained in artificially contaminated milk and poultry meat, with detection limits down to 1 × 102 CFU/ml and 1 × 104 CFU/25 g, respectively. On-chip AST determined Campylobacter antibiotic susceptibilities by the lowest concentration of antibiotics that can inhibit bacterial growth (i.e., no color change observed). High coincidences (91% to 100%) of on-chip AST and the conventional agar dilution method were achieved against several clinically important antibiotics. For a presumptive colony, on-chip identification and AST were completed in parallel within 24 h, whereas standard methods, including biochemical assays and traditional culture-based AST, take several days for multiple sequential steps. In conclusion, this lab-on-a-chip device can achieve rapid and reliable detection of antibiotic-resistant Campylobacter spp. IMPORTANCE Increasing concerns of antibiotic-resistant Campylobacter spp. with regard to public health emphasize the importance of efficient and fast detection. This study described the timely identification and antimicrobial susceptibility testing of Campylobacter spp. by using a microfluidic device. Our developed method not only reduced the total analysis time, but it also simplified food sample preparation and chip operation for end users. Due to the miniaturized size of the lab-on-a-chip platform, the detection was achieved by using up to 1,000 times less of the reagents than with standard reference methods, making it a competitive approach for rapid screening and surveillance study in food industries. In addition, multiple clinically important Campylobacter species (C. jejuni, C. coli, and C. lari) could be tested by our device. This device has potential for wide application in food safety management and clinical diagnostics, especially in resource-limited regions.


Sign in / Sign up

Export Citation Format

Share Document