Optimal sizing of different configurations of renewable distributed generation systems for a green building in Egypt

Author(s):  
Diaa Ahmed Madboly ◽  
Shady H.E. Abdel Aleem ◽  
Ahmed M. Ibrahim
Energies ◽  
2019 ◽  
Vol 12 (9) ◽  
pp. 1728 ◽  
Author(s):  
José Adriano da Costa ◽  
David Alves Castelo Branco ◽  
Max Chianca Pimentel Filho ◽  
Manoel Firmino de Medeiros Júnior ◽  
Neilton Fidelis da Silva

The integration of renewable distributed generation into distribution systems has been studied comprehensively, due to the potential benefits, such as the reduction of energy losses and mitigation of the environmental impacts resulting from power generation. The problem of minimizing energy losses in distribution systems and the methods used for optimal integration of the renewable distributed generation have been the subject of recent studies. The present study proposes an analytical method which addresses the problem of sizing the nominal power of photovoltaic generation, connected to the nodes of a radial distribution feeder. The goal of this method is to minimize the total energy losses during the daily insolation period, with an optimization constraint consisting in the energy flow in the slack bus, conditioned to the energetic independence of the feeder. The sizing is achieved from the photovoltaic generation capacity and load factors, calculated in time intervals defined in the typical production curve of a photovoltaic unit connected to the distribution system. The analytical method has its foundations on Lagrange multipliers and relies on the Gauss-Jacobi method to make the resulting equation system solution feasible. This optimization method was evaluated on the IEEE 37-bus test system, from which the scenarios of generation integration were considered. The obtained results display the optimal sizing as well as the energy losses related to additional power and the location of the photovoltaic generation in distributed generation integration scenarios.


2018 ◽  
Vol 7 (3.15) ◽  
pp. 40 ◽  
Author(s):  
Mohd Effendi Amran ◽  
Mohd Nabil Muhtazaruddin

This paper presents an optimization solution for renewable Distributed Generation (DG), as imposed in the Green Building Rating System (GBRS) for a public hospital. Solar photovoltaic DG unit (PV-DG) is identified as a type of DG used in this paper. The proposed optimization via PV-DG coordination will improve the sustainable energy performance of the green building by power loss reduction within accepted lower losses region using Artificial Bee Colony (ABC) algorithm. The setup input data from one of Malaysian public hospitals’ power distribution system is been adopted and simulation results via MATLAB programming show that the optimization of DG forming into bigger-scale imposed system provides a better outcome in minimization of total power losses within appropriate voltage profile as compared to current PV-DG imposed in GBRS. The objective function representing total power losses which also supported by related literature give a measure that forming sufficient and optimal PV-DG assessment criteria is highly important, thus, current PV-DG assessment in GBRS is proposed to be reviewed into new parameter setting for public hospital due to its’ high energy demand and distinctive electrical load profile.  


Sign in / Sign up

Export Citation Format

Share Document