Low Sensitivity Coupled CMOS CCII Biquads

Author(s):  
Edi Emanovic ◽  
Drazen Jurisic ◽  
George S. Moschytz
Keyword(s):  
Author(s):  
Murray Vernon King ◽  
Donald F. Parsons

Effective application of the high-voltage electron microscope to a wide variety of biological studies has been restricted by the radiation sensitivity of biological systems. The problem of radiation damage has been recognized as a serious factor influencing the amount of information attainable from biological specimens in electron microscopy at conventional voltages around 100 kV. The problem proves to be even more severe at higher voltages around 1 MV. In this range, the problem is the relatively low sensitivity of the existing recording media, which entails inordinately long exposures that give rise to severe radiation damage. This low sensitivity arises from the small linear energy transfer for fast electrons. Few developable grains are created in the emulsion per electron, while most of the energy of the electrons is wasted in the film base.


Author(s):  
James F. Mancuso ◽  
Leo A. Fama ◽  
William B. Maxwell ◽  
Jerry L. Lehman ◽  
Hasso Weiland ◽  
...  

Micro-diffraction based crystallography is essential to the design and development of many classes of ‘crafted materials’. Although the scanning electron microscope can provide crystallographic information with high spatial resolution, its current utility is severely limited by the low sensitivity of existing diffraction techniques (ref: Dingley). Previously, Joy showed that energy filtering increased contrast and pattern visibility in electron channelling. This present paper discribes the effect of energy filtering on EBSP sensitivity and backscattered SEM imaging.The EBSP detector consisted of an electron energy filter, a microchannel plate detector, a phosphor screen, optical coupler, and a slow scan CCD camera. The electrostatic energy filter used in this experiment was constructed as a cone with 5 coaxial electrodes. The angular field-of-view of the filter was approximately 38°. The microchannel plate, which was the initial sensing component, had high gain and had 50% to 80% detection efficiency for the low energy electrons that passed through the retarding field filter.


1996 ◽  
Vol 5 (1) ◽  
pp. 90-96 ◽  
Author(s):  
Frank E. Musiek ◽  
Cynthia A. McCormick ◽  
Raymond M. Hurley

We performed a retrospective study of 26 patients with acoustic tumors and 26 patients with otologically diagnosed cochlear pathology to determine the sensitivity (hit rate), specificity (false-alarm rate), and efficiency of six auditory brainstem response indices. In addition, a utility value was determined for each of these six indices. The I–V interwave interval, the interaural latency difference, and the absolute latency of wave V provided the highest hit rates, the best A’ values and good utility. The V/I amplitude ratio index provided high specificity but low sensitivity scores. In regard to sensitivity and specificity, using the combination of two indices provided little overall improvement over the best one-index measures.


1989 ◽  
Vol 28 (06) ◽  
pp. 234-242 ◽  
Author(s):  
U. Sechtem ◽  
Sabine Langkamp ◽  
M. Jungehülsing ◽  
H. H. Hilger ◽  
H. Schicha ◽  
...  

Fortyfour patients with recent cardiac catheterization because of recurrent chest pain after coronary artery bypass surgery were studied by magnetic resonance imaging to evaluate graft patency. To assess the efficacy of this non-invasive method 92 coronary artery bypass grafts were examined by the spin-echo technique. ECG-gated transversal sections were acquired between the diaphragm and the aortic arch. The specificity of magnetic resonance imaging was 83% (48/58) for patent grafts. However, the sensitivity in the detection of occluded bypasses was only 56% (19/34). Despite the good specificity, clinical applications of this method are limited because of its low sensitivity.


1974 ◽  
Vol 32 (02/03) ◽  
pp. 483-491
Author(s):  
E. A Loeliger ◽  
M. J Boekhout-Mussert ◽  
L. P van Halem-Visser ◽  
J. D. E Habbema ◽  
H de Jonge

SummaryThe present study concerned the reproducibility of the so-called prothrombin time as assessed with a series of more commonly used modifications of the Quick’s onestage assay procedure, i.e. the British comparative reagent, homemade human brain thromboplastin, Simplastin, Simplastin A, and Thrombotest. All five procedures were tested manually on pooled lyophilized normal and patients’ plasmas. In addition, Simplastin A and Thrombotest were investigated semiautomatically on individual freshly prepared patients’ plasmas. From the results obtained, the following conclusions may be drawn :The reproducibility of results obtained with manual reading on lyophilized plasmas is satisfactory for all five test procedures. For Simplastin, the reproducibility of values in the range of insufficient anticoagulation is relatively low due to the low discrimination power of the test procedure in the near-normal range (so-called low sensitivity of rabbit brain thromboplastins). The reproducibility of Thrombotest excels as a consequence of its particularly easily discerned coagulation endpoint.The reproducibility of Thrombotest, when tested on freshly prepared plasmas using Schnitger’s semiautomatic coagulometer (a fibrinometer-liJce apparatus), is no longer superior to that of Simplastin A.The constant of proportionality between the coagulation times formed with Simplastin A and Thrombotest was estimated at 0.64.Reconstituted Thrombotest is stable for 24 hours when stored at 4° C, whereas reconstituted Simplastin A is not.The Simplastin A method and Thrombotest seem to be equally sensitive to “activation” of blood coagulation upon storage.


1999 ◽  
Vol 19 (04) ◽  
pp. 168-175 ◽  
Author(s):  
M. Weippert-Kretschmer ◽  
V. Kretschmer

SummaryPerioperative bleeding complications due to disorders of primary haemostasis are often underestimated. Routine determination of primary haemostasis is still problematic. The in vivo bleeding time (BT) shows low sensitivity and high variability. In this contribution the results and experiences with the IVBT having been obtained in various studies and during 10 years of routine use are reported. Patients and Methods: Blood donors before and after ASA ingestion, patients with thrombocytopenia as well as congenital and acquired platelet function disorders. Monitoring of desmopressin efficacy. IVBT with Thrombostat 4000 (tests with CaCl2 = TST-CaCl2 and ADP = TST-ADP) and PFA-100 (test cartridges with epinephrine = PFA-EPI and ADP = PFA-ADP). Results and Conclusions: IVBT becomes abnormal with platelet counts <100,000/μl. With platelet counts <50,000/μl the results are mostly outside the methodical range. IVBT proved clearly superior to BT in von Willebrand syndrome (vWS). All 16 patients with vWS were detected by PFA-EPI, whereas with BT 7 of 10 patients with moderate and 1 of 6 patients with mild forms of vWS were spotted. The majority of acquired and congenital platelet function disorders with relevant bleeding tendency were detectable by IVBT. Sometimes diagnostic problems arose in case of storage pool defect. Four to 12 h after ingestion of a single dose of 100 mg ASA the TST-CaCl2 became abnormal in all cases, the PFA-EPI only in 80%. However, the ASA sensitivity of TST-CaCl2 proved even too high when looking for perioperative bleeding complications in an urological study. Therefore, the lower ASS sensitivity of the PFA-100 seems to be rather advantageous for the estimation of a real bleeding risk. The good efficacy of desmopressin in the majority of cases with mild thrombocytopenia, congenital and acquired platelet function disorders and even ASS-induced platelet dysfunction could be proven by means of the IVBT. Thus IVBT may help to increase the reliability of the therapy. However, the IVBT with the PFA-100 is not yet fully developed. Nevertheless, routine use can be recommended when special methodical guidelines are followed.


1984 ◽  
Vol 52 (01) ◽  
pp. 057-059 ◽  
Author(s):  
E Dejana ◽  
M Furlan ◽  
B Barbieri ◽  
M B Donati ◽  
E A Beck

SummaryRat platelets do not respond to ristocetin in their own plasma nor do they aggregate in the presence of bovine or porcine factor VIII von Willebrand factor (F VIII R:WF) or human F VIII R:WF in presence of ristocetin. However, rat plasma supports ristocetin induced aggregation of washed human platelets. In this study we report on purification of rat F VIII R:WF from cryoprecipitate. Similarly to porcine or bovine material, purified rat F VIII R:WF induced aggregation of human washed fixed platelets. This effect was enhanced by addition of ristocetin and was not modified by addition of albumin. Rat washed platelets were aggregated by ristocetin in the presence of rat or human F VIII R:WF provided that high concentrations of ristocetin are added in a system essentially free of extraneous proteins. Increasing concentrations of albumin dramatically reduced the ability of ristocetin to aggregate rat platelets while human platelet aggregation by human or rat F VIII R:WF was only moderately affected.These studies show that rat F VIII R:WF can interact with rat and human platelets. The lack of response of rat platelets to ristocetin in their own plasma is most likely due to a low sensitivity of rat platelets to this drug and to an inhibitory activity of plasma proteins on this reaction.


2014 ◽  
Author(s):  
Francisco Javier Vilchez-Lopez ◽  
Isabel Mateo-Gavira ◽  
Florentino Carral-San Laureano ◽  
Maria Victoria Garcia-Palacios ◽  
Jose Ortego-Rojo ◽  
...  

2020 ◽  
Author(s):  
Baojian Xiong ◽  
Yue Li ◽  
Yin Wei ◽  
Søren Kramer ◽  
Zhong Lian

Cross-coupling between substrates that can be easily derived from phenols is highly attractive due to the abundance and low cost of phenols. Here, we report a dual nickel/palladium-catalyzed reductive cross-coupling between aryl tosylates and aryl triflates; both substrates can be accessed in just one step from readily available phenols. The reaction has a broad functional group tolerance and substrate scope (>60 examples). Furthermore, it displays low sensitivity to steric effects demonstrated by the synthesis of a 2,2’disubstituted biaryl and a fully substituted aryl product. The widespread presence of phenols in natural products and pharmaceuticals allow for straightforward late-stage functionalization, illustrated with examples such as Ezetimibe and tyrosine. NMR spectroscopy and DFT calculations indicate that the nickel catalyst is responsible for activating the aryl triflate, while the palladium catalyst preferentially reacts with the aryl tosylate.


Sign in / Sign up

Export Citation Format

Share Document