Dead time correction in the DP5 digital pulse processor

Author(s):  
Robert H. Redus ◽  
Alan C. Huber ◽  
David J. Sperry
2015 ◽  
Vol 22 (5) ◽  
pp. 1190-1201 ◽  
Author(s):  
Leonardo Abbene ◽  
Gaetano Gerardi

Dead-time losses are well recognized and studied drawbacks in counting and spectroscopic systems. In this work the abilities on dead-time correction of a real-time digital pulse processing (DPP) system for high-rate high-resolution radiation measurements are presented. The DPP system, through a fast and slow analysis of the output waveform from radiation detectors, is able to perform multi-parameter analysis (arrival time, pulse width, pulse height, pulse shape,etc.) at high input counting rates (ICRs), allowing accurate counting loss corrections even for variable or transient radiations. The fast analysis is used to obtain both the ICR and energy spectra with high throughput, while the slow analysis is used to obtain high-resolution energy spectra. A complete characterization of the counting capabilities, through both theoretical and experimental approaches, was performed. The dead-time modeling, the throughput curves, the experimental time-interval distributions (TIDs) and the counting uncertainty of the recorded events of both the fast and the slow channels, measured with a planar CdTe (cadmium telluride) detector, will be presented. The throughput formula of a series of two types of dead-times is also derived. The results of dead-time corrections, performed through different methods, will be reported and discussed, pointing out the error on ICR estimation and the simplicity of the procedure. Accurate ICR estimations (nonlinearity < 0.5%) were performed by using the time widths and the TIDs (using 10 ns time bin width) of the detected pulses up to 2.2 Mcps. The digital system allows, after a simple parameter setting, different and sophisticated procedures for dead-time correction, traditionally implemented in complex/dedicated systems and time-consuming set-ups.


2020 ◽  
Vol 7 (1) ◽  
Author(s):  
Andrea Frezza ◽  
Corentin Desport ◽  
Carlos Uribe ◽  
Wei Zhao ◽  
Anna Celler ◽  
...  

2018 ◽  
Vol 25 (2) ◽  
pp. 484-495 ◽  
Author(s):  
Suelen F. Barros ◽  
Vito R. Vanin ◽  
Alexandre A. Malafronte ◽  
Nora L. Maidana ◽  
Marcos N. Martins

Dead-time effects in X-ray spectra taken with a digital pulse processor and a silicon drift detector were investigated when the number of events at the low-energy end of the spectrum was more than half of the total, at counting rates up to 56 kHz. It was found that dead-time losses in the spectra are energy dependent and an analytical correction for this effect, which takes into account pulse pile-up, is proposed. This and the usual models have been applied to experimental measurements, evaluating the dead-time fraction either from the calculations or using the value given by the detector acquisition system. The energy-dependent dead-time model proposed fits accurately the experimental energy spectra in the range of counting rates explored in this work. A selection chart of the simplest mathematical model able to correct the pulse-height distribution according to counting rate and energy spectrum characteristics is included.


Electronics ◽  
2021 ◽  
Vol 10 (2) ◽  
pp. 220
Author(s):  
Cheng Lin ◽  
Jilei Xing ◽  
Xingming Zhuang

Sensorless control technology of PMSMs is of great importance for safety and reliability in electric vehicles. Among all existing methods, only the extended flux-based method has great performance over all speed range. However, the accuracy and reliability of the extended flux rotor position observer are greatly affected by the dead-time effect. In this paper, the extended flux-based observer is adopted to develop a sensorless control system. The influence of dead-time effect on the observer is analyzed and a dead-time correction method is specially designed to guarantee the reliability of the whole control system. A comparison of estimation precision among the extended flux-based method, the electromotive force (EMF)-based method and the high frequency signal injection method is given by simulations. The performance of the proposed sensorless control system is verified by experiments. The experimental results show that the proposed extended flux-based sensorless control system with dead-time correction has satisfactory performance over full speed range in both loaded and non-loaded situations. The estimation error of rotor speed is within 4% in all working conditions. The dead-time correction method improves the reliability of the control system effectively.


2012 ◽  
Vol 44 (9) ◽  
pp. 1287-1293 ◽  
Author(s):  
Akio Takano ◽  
Hisataka Takenaka ◽  
Satoshi Ichimaru ◽  
Hidehiko Nonaka

2005 ◽  
Vol 32 (6Part10) ◽  
pp. 1998-1998
Author(s):  
M Lin ◽  
C Lee ◽  
T Chao ◽  
C Tung

Sign in / Sign up

Export Citation Format

Share Document