scholarly journals Improved contrast and spatial resolution with single photon counting (SPC) for an area X-ray imager, the newly developed high-resolution Micro-Angiographic Fluoroscopic (MAF) detector

Author(s):  
A. Jain ◽  
A. Kuhls-Gilcrist ◽  
D.R. Bednarek ◽  
S. Rudin
2018 ◽  
Vol 13 (12) ◽  
pp. C12006-C12006 ◽  
Author(s):  
D. Vavřík ◽  
D. Kytýř ◽  
S. Mühleder ◽  
M. Vopálenský ◽  
P. Beneš ◽  
...  

2010 ◽  
Vol 37 (6Part8) ◽  
pp. 3356-3357
Author(s):  
A Panse ◽  
A Jain ◽  
W Wang ◽  
R Yao ◽  
D Bednarek ◽  
...  

2021 ◽  
Vol 16 (12) ◽  
pp. C12027
Author(s):  
A. Krzyzanowska

Abstract Hybrid pixel radiation detectors working in a single-photon counting mode have gained increasing attention due to their noiseless imaging and high dynamic range. Due to the fact that sensors of different materials can be attached to the readout circuit, they allow operation with a wide range of photon energies. The performance of the single photon counting detectors is limited by pile-up. To allow a detector to work under high flux conditions, the pixel size is reduced, which minimizes detector dead time. However, with smaller pixel sizes the charge sharing effect, a phenomenon that deteriorates both detection efficiency and spatial resolution is more profound. The influence of charge sharing on the detector performance can be quantified using parameterization of the s-curve obtained in the spectral response measurements. The article presents the measurements of the response function of a hybrid pixelated photon counting detector for certain primary energy, which corresponds to the probability of detecting a photon as a function of its energy deposition. The measurements were carried out using an X-ray tube by performing a threshold scan during illumination with X-ray photons of a 1.5 mm and 0.75 mm thick CdTe detector with 100 µm pixel pitch. The charge size cloud depends on the sensor material, the bias voltage, and the sensor thickness. Therefore, the experimental data from a sensor biased with different bias voltages are compared to the theoretical results based on a cascaded model of a single-photon counting segmented silicon detector. The study of the charge sharing influence on the spatial resolution of the CdTe detector will serve for a further study of the possible implementations of the algorithms achieving subpixel resolution, in which the charge sharing becomes the desired effect since the charge division in the pixels is used to interpolate the photon interaction position.


2012 ◽  
Vol 20 (1) ◽  
pp. 153-159 ◽  
Author(s):  
Patrik Vagovič ◽  
Dušan Korytár ◽  
Angelica Cecilia ◽  
Elias Hamann ◽  
Libor Švéda ◽  
...  

The performance of a recently developed full-field X-ray micro-imaging system based on an in-line Bragg magnifier is reported. The system is composed of quasi-channel-cut crystals in combination with a Medipix single-photon-counting detector. A theoretical and experimental study of the imaging performance of the crystals–detector combination and a comparison with a standard indirect detector typically used in high-resolution X-ray imaging schemes are reported. The spatial resolution attained by our system is about 0.75 µm, limited only by the current magnification. Compared with an indirect detector system, this system features a better efficiency, signal-to-noise ratio and spatial resolution. The optimal working resolution range of this system is between ∼0.4 µm and 1 µm, filling the gap between transmission X-ray microscopes and indirect detectors. Applications for coherent full-field imaging of weakly absorbing samples are shown and discussed.


Author(s):  
A. Bergamaschi ◽  
R. Dinapoli ◽  
B. Henrich ◽  
I. Johnson ◽  
A. Mozzanica ◽  
...  

2004 ◽  
Vol 75 (10) ◽  
pp. 3705-3707 ◽  
Author(s):  
C. Stoeckl ◽  
W. Theobald ◽  
T. C. Sangster ◽  
M. H. Key ◽  
P. Patel ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document