A Distubuted Voltage and Frequency Restoration Method for Islanded Microgrid

Author(s):  
Guangyu Jia ◽  
Jiawei Chen ◽  
Pengfei Wang ◽  
Jie Chen
2020 ◽  
Vol 10 (5) ◽  
pp. 1558
Author(s):  
Jin-Oh Lee ◽  
Yun-Su Kim

This paper presents a control method for inverter-interfaced distributed generation (DG) and energy storage systems (ESSs) in an islanded microgrid. The proposed method is focused on secondary control, particularly frequency restoration and maintaining the ESSs’ state of charge (SOC). To recover frequency deviation due to load change, an ESS is used as a droop-controlled grid-forming source. However, the grid-forming ESS cannot manage its own SOC, since it cannot control its own output power; hence, grid-feeding DGs are used to maintain the SOC within a desired range. Management of the SOC, as well as frequency restoration, is conducted by using local controllers without any communication devices, since dependency on communication may deteriorate system reliability in the case of failure. The proposed method for maintaining SOC can be realized by adjusting the system frequency, which is the only value that can be measured locally with almost the same value at every node in a steady state. Frequency restoration can be achieved by a simple ON/OFF scheme of the integral controller with a hysteresis loop to solve problems caused by differences between frequency measurements or set points among DGs.


Author(s):  
Norio Baba ◽  
Norihiko Ichise ◽  
Syunya Watanabe

The tilted beam illumination method is used to improve the resolution comparing with the axial illumination mode. Using this advantage, a restoration method of several tilted beam images covering the full azimuthal range was proposed by Saxton, and experimentally examined. To make this technique more reliable it seems that some practical problems still remain. In this report the restoration was attempted and the problems were considered. In our study, four problems were pointed out for the experiment of the restoration. (1) Accurate beam tilt adjustment to fit the incident beam to the coma-free axis for the symmetrical beam tilting over the full azimuthal range. (2) Accurate measurements of the optical parameters which are necessary to design the restoration filter. Even if the spherical aberration coefficient Cs is known with accuracy and the axial astigmatism is sufficiently compensated, at least the defocus value must be measured. (3) Accurate alignment of the tilt-azimuth series images.


1982 ◽  
Vol 47 (2) ◽  
pp. 194-199 ◽  
Author(s):  
Bernd Weinberg ◽  
Yoshiyuki Horii ◽  
Eric Blom ◽  
Mark Singer

Prosthesis airway resistance calculations were completed for five Blom-Singer prostheses and esophageal source airway resistance estimated were made of five laryngectomized patients using the Singer-Blom voice restoration method. Airway resistance of the Blom-Singer prostheses ranged from 46 to 121 cmH 2 O/LPS, while source airways resistance in these subjects ranged from about 155 to 270 cmH 2 O/LPS. These results revealed that the opposition of the voicing sources used in esophageal speech production to airflow through them is substantial and larger than that established for the normal, laryngeal source. Findings are interpreted to highlight major advantages the Singer-Blom (1980) method of speech/voice restoration has over esophageal speech/voice produced on a conventional basis and to reveal specific reasons for the failure of may laryngectomized patients to develop consistent voice and functionally serviceable speech.


Author(s):  
M. Kohansal ◽  
G.B. Gharehpetian ◽  
M. Abedi ◽  
M. J. Sanjari

Sign in / Sign up

Export Citation Format

Share Document