Voltage Sensorless Control of a Three-phase Grid Connected Inverter with LCL filter based on Passivity under Non-ideal Grid Voltage Conditions

Author(s):  
Vikram Roy Chowdhury ◽  
Jonathan W. Kimball
2021 ◽  
Vol 3 (3) ◽  
Author(s):  
Ayaz Ahmad ◽  
L. Rajaji ◽  
A. Iqbal

AbstractDistributed generators are playing a vital role in supporting the grid in ever-increasing energy demands. Grid code regulation must be followed when integrating the photovoltaic inverter system to the grid. The paper investigates and analyzes a controller model for grid-connected PV inverters to inject sinusoidal current to the grid with minimum distortion. To achieve better tracking and disturbance rejection, a DSP-based current controller is designed with LCL filter. The controller gets the current feedback from the grid, compares it with reference current, and calculates duty cycle to generate PWM pulses to trigger H-bridge converters. The grid voltage is loaded to the initial value in proposed PR controller to ensure the initial inverter voltage to match the grid voltage. The paper presents a novel current controller algorithm for grid-connected inverter system, and simulation is done. A detailed analysis has been carried out to validate the proposed design algorithm. Experimental implementation of the current controller in the DC/AC converter circuits with an LCL filter is done for 5.4 kW to validate and match the simulation model.


2012 ◽  
Vol 220-223 ◽  
pp. 1175-1180
Author(s):  
Guo Tao Yang ◽  
Zhi Yi Sun ◽  
Li Qun Liu

In order to gain the same amplitude、frequency and phase between the output voltage of the inverter and the grid voltage, the phase-locked loop (PLL) technology is widely used in grid-connected photovoltaic (PV) generating system, which is normally used to obtain instantaneous phase information to achieve the grid-connected purpose of PV inverter. The detective accuracy of frequency and phase of the grid voltage is directly affected by the PLL. Two software PLL technologies are compared by using the simulation analysis which is based on the d-q transformation. To provide the basis for the design of grid-connected inverter, the advantages and disadvantages of two software PLL technologies are analyzed under different grid failure conditions, such as one phase voltage dropped, two of three phase voltage (TPV) dropped, grid frequency mutated, and grid voltage offset, etc. Particularly, the appropriate PLL technology can effectively improve the grid-connected ability of PV inverter under the grid voltage offset or unbalance conditions.


Sign in / Sign up

Export Citation Format

Share Document