Power quality of Single-Phase Standalone Inverter with linear and nonlinear load

Author(s):  
Jose Luis Mata Ledesma ◽  
Oscar Carranza Castillo ◽  
Ruben Ortega Gonzalez ◽  
Jaime Jose Rodriguez Rivas
2014 ◽  
Vol 687-691 ◽  
pp. 3411-3414
Author(s):  
Jia Yong Chen ◽  
Kun Ya Guo ◽  
Peng Jin ◽  
Shu Han Wang

Electrified railway traction transformer is a pivot that connects the electric locomotive and the public grid. Therefore, power quality problems caused by electric locomotive such as three-phase voltage imbalance, great voltage fluctuation and high harmonic content can be transmitted to the public grid via the traction transformer. To solve this problem, the solution of two sets of single-phase SVG (Static Var Generator) in back-to-back operation to solve power quality problems of the electrified railway is raised. This solution has been proved by practice effective in improving power quality of the traction transformer.


2012 ◽  
Vol 512-515 ◽  
pp. 1199-1204
Author(s):  
Yong Zhang ◽  
Jing Shuang Shen ◽  
Hai Feng Zheng

This paper explores methods to improve the power quality of large, single-phase, thyristor controlled equipment within industrial plants. An advanced shunt single phase power filter for the compensation of instantaneous harmonic current components in direct coupled booster melting in glass furnaces is presented. The validity of the excellent filtering characteristics is verified by a previous installation.


2013 ◽  
Vol 380-384 ◽  
pp. 3149-3154
Author(s):  
Han Guo Yu ◽  
Jian Ru Wan ◽  
Ran Liu

According to the power quality problems of micro-grid, this paper presents a control program of the Unified Power Quality Conditioner (UPQC) to improve the micro-grid power quality.The shunt side of UPQC is used to eliminate the harmonic current brought by nonlinear load into the micro-grid. And the conditioner series part is used to suppress distributed new energy generation intermittence. In the paper synchronous coordinate transformation is used to detect compensated components and tracking control method is adopted to control the converter. The simulation results demonstrate the effectiveness of the UPQC on improving the power quality of the micro-grid.


Author(s):  
Madhu B. R. ◽  
Dinesh M. N. ◽  
Tsewang Thinlas ◽  
Deril Menezes

Power quality is the most significant factor of power sector. The end user equipment such as induction motor, inverters, rectifiers inject harmonics into power system that influences the quality of power delivered. The presence of harmonics forces the use of instantaneous reactive power theory to calculate instantaneous power that helps in finding the compensating currents to eliminate harmonics. The control action required by active filter is accomplished by STM32F303RET6 microcontroller. Single phase induction motor is used as a dynamic nonlinear load in one of the three phases and resistive loads on the other two phases. TRIAC based RC triggering circuit was used to control the single phase induction motor. This paper presents the simulation and hardware implementation of shunt active power filter for 3 phase 4 wire unbalanced system. The hardware results show that THD in the source side has been reduced from 50.7% to 9.6% by implementing the SAPF.


Author(s):  
И.Е. Кажекин ◽  
С.П. Финько ◽  
М.С. Харитонов

Описаны результаты исследований влияния показателей качества электроэнергии на токи однофазных замыканий в судовых электроустановках. Выявлены основные элементы бортовых электроустановок, влияющие на качество электроэнергии. Проанализировано формирование высших гармоник в токе однофазного замыкания. На физической модели электроустановки проведены исследования влияния нелинейной нагрузки на ток однофазного замыкания. Результаты экспериментов подтвердили установленные закономерности. Выявлено, что в установившемся режиме ток однофазного замыкания определяется не только величиной фазной емкости и напряжением сети, но и несинусоидальностью тока нагрузки. Экспериментально показано, что высшие гармоники, присутствующие в токе нагрузки, усиливаются в токе однофазного замыкания. При этом увеличение их амплитуд пропорционально номеру гармоники и ее амплитуде в токе нагрузки. Экспериментально установлено, что формирование высших гармоник в токе однофазного замыкания в результате эмиссии нелинейной нагрузкой приводит к увеличению его действующего значения. The paper represents the research results of the power quality indicators influence on the currents of single-phase ground faults in ship electrical installations. The main elements of on-board electrical installations that affect the quality of electricity are identified. The process of higher harmonics formation in the single-phase ground fault current is analyzed. Studies of the nonlinear load influence on the single-phase fault current are carried out on the physical model of the electrical installation. The experimental results confirmed the established patterns. For the steady-state mode it was discovered that the single-phase ground fault current is determined not only by the phase capacitance value and the mains voltage, but also by the non-sinusoidality of the load current. It has been shown experimentally that the higher harmonics of the load current are amplified in the single-phase ground fault current. In this case, the increase at their amplitudes is proportional to the harmonic number and its amplitude in the load current. It has been experimentally established that the formation of higher harmonics at a single-phase ground fault current as a result of emission by a nonlinear load leads to an increase in its effective value.


Sign in / Sign up

Export Citation Format

Share Document