scholarly journals Energetic Considerations in Quantum Target Ranging

Author(s):  
Athena Karsa ◽  
Stefano Pirandola
Keyword(s):  
2008 ◽  
Vol 18 (02) ◽  
pp. 393-400 ◽  
Author(s):  
ROBERT J. GRASSO ◽  
JOHN C. WIKMAN ◽  
DAVID P. DROUIN ◽  
GEORGE F. DIPPEL ◽  
PAUL I. EGBERT

BAE SYSTEMS has developed a Low Cost Targeting System (LCTS) consisting of a FLIR for target detection, laser-illuminated, gated imaging for target identification, laser rangefinder and designator, GPS positioning, and auto-tracking capability within a small compact system size. The system is based upon BAE Systems proven micro-bolometer passive LWIR camera coupled with Intevac's new EBAPS camera. A dual wavelength diode pumped laser provides eyesafe ranging and target illumination, as well as designation; a custom detector module senses the return pulse for target ranging and to set the range gates for the gated camera. Trials show that the current detectors offer complete extinction of signals outside of the gated range, thus, providing high resolution within the gated region. The images have shown high spatial resolution arising from the use of solid state focal plane array technology. Imagery has been collected in both the laboratory and the field to verify system performance during a variety of operating conditions.


2021 ◽  
Author(s):  
Qingsheng Mu ◽  
Jun Wei ◽  
Zhugang Yuan ◽  
Yuheng Yin

2021 ◽  
Author(s):  
Dong-Zhou Zhong ◽  
Zhe Xu ◽  
Ya-Lan Hu ◽  
Ke-Ke Zhao ◽  
Jin-Bo Zhang ◽  
...  

Abstract In this work, we utilize three parallel reservoir computers using semiconductor lasers with optical feedback and light injection to model radar probe signals with delays. Three radar probe signals are generated by driving lasers constructed by a three-element lase array with self-feedback. The response lasers are implemented also by a three-element lase array with both delay-time feedback and optical injection, which are utilized as nonlinear nodes to realize the reservoirs. We show that each delayed radar probe signal can well be predicted and to synchronize with its corresponding trained reservoir, even when there exist parameter mismatches between the response laser array and the driving laser array. Based on this, the three synchronous probe signals are utilized for ranging to three targets, respectively, using Hilbert transform. It is demonstrated that the relative errors for ranging can be very small and less than 0.6%. Our findings show that optical reservoir computing provides an effective way for applications of target ranging.


1991 ◽  
Vol 66 (6) ◽  
pp. 1951-1964 ◽  
Author(s):  
D. C. Fitzpatrick ◽  
N. Suga ◽  
H. Misawa

1. FM-FM neurons in the auditory cortex of the mustached bat, Pteronotus parnellii, are specialized to process target range. They respond when the terminal frequency-modulated component (TFM) of a biosonar pulse is paired with the TFM of the echo at a particular echo delay. Recently, it has been suggested that the initial FM components (IFMs) of biosonar signals may also be important for target ranging. To examine the possible role of IFMs in target ranging, we characterized the properties of IFMs and TFMs in biosonar pulses emitted by bats swung on a pendulum. We then studied responses of FM-FM neurons to synthesized biosonar signals containing IFMs and TFMs. 2. The mustached bat's biosonar signal consists of four harmonics, of which the second (H2) is the most intense. Each harmonic has an IFM in addition to a constant-frequency component (CF) and a TFM. Therefore each pulse potentially consists of 12 components, IFM1-4, CF1-4, and TFM1-4. The IFM sweeps up while the TFM sweeps down. 3. The IFM2 and TFM2 depths (i.e., bandwidths) were measured in 217 pulses from four animals. The mean IFM2 depth was much smaller than the mean TFM2 depth, 2.87 +/- 1.52 (SD) kHz compared with 16.27 +/- 1.08 kHz, respectively. The amplitude of the IFM2 continuously increased throughout its duration and was always less than the CF2 amplitude, whereas the TFM2 was relatively constant in amplitude over approximately three-quarters of its duration and was often the most intense part of the pulse. The maximum amplitude of the IFM2 was, on average, 11 dB smaller than that of the TFM2. Because range resolution increases with depth and the maximum detectable range increases with signal amplitude, the IFMs are poorly suited for ranging compared with the TFMs. 4. FM-FM neurons (n = 77) did not respond or responded very poorly to IFMs with depths and intensities similar to those emitted on the pendulum. The mean IFM2 depth at which a just-noticeable response appeared was 4.48 +/- 1.98 kHz. Only 14% of the pulses emitted on the pendulum had IFM2 depths that exceeded the mean IFM2 depth threshold of FM-FM neurons. 5. Most FM-FM neurons responded to IFMs that had depths comparable with those of TFMs. However, when all parameters were adjusted to optimize the response to TFMs and then readjusted to maximize the response to IFMs, 52% of 27 neurons tested responded significantly better to the optimal TFMs than to the optimal IFMs (P less than 0.05, t test).(ABSTRACT TRUNCATED AT 400 WORDS)


2012 ◽  
Vol 13 (5) ◽  
pp. 673-682 ◽  
Author(s):  
Sven Schörnich ◽  
Andreas Nagy ◽  
Lutz Wiegrebe

2005 ◽  
Author(s):  
Xiao Lin Sui ◽  
Zheng Yu Zhang ◽  
Xiao Long Zhang ◽  
Fei Xuan ◽  
Ming Yu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document