Analysis of the Characteristics of Gas-Solid Insulation Surface Discharge under High Frequency Sinusoidal Electrical Stress and Construction of Simulation Model

Author(s):  
Yan Qiyue ◽  
Zhang Li ◽  
Zou Liang ◽  
Zhao Tong
Polymers ◽  
2021 ◽  
Vol 13 (24) ◽  
pp. 4387
Author(s):  
Zhaoliang Xing ◽  
Wenhan Chen ◽  
Zhihui Li ◽  
Naifan Xue ◽  
Fei Li ◽  
...  

Polyimide (PI) can be used as a cladding insulation for high frequency power transformers, and along-side discharge can lead to insulation failure, so material modification techniques are used. In this paper, different doped nano-SiO2 are introduced into polyimide for nanocomposite modification. The results of testing the life time of high-frequency electrical stress along-side discharge show that the 10% SiO2 doping has the longest life time. The results show that: for composites prone to corona, their flashover causes more damage, and both positive half-cycle and polarity reversal discharges are more violent; compared to pure PI, the positive half-cycle and overall discharge amplitude and number of modified films are smaller, but the negative half-cycle is larger; at creeping development stages, the number of discharges is smaller, and the discharge amplitude of both films fluctuates in the mid-term, with the modified films having fewer discharges and the PI films discharging more violently in the later stages. The increase in the intensity of the discharge was greater in the later stages, and the amplitude and number of discharges were much higher than those of the modified film, which led to a rapid breakdown of the pure polyimide film. Further research found that resistivity plays an important role in the structural properties of the material in the middle and late stages, light energy absorption in the modified film plays an important role, the distribution of traps also affects the discharge process, and in the late stages of the discharge, the heating of the material itself has a greater impact on the breakdown, so the pure polyimide film as a whole discharges more severely and has the shortest life.


2020 ◽  
Vol 6 (2) ◽  
pp. 65-73 ◽  
Author(s):  
Neris Peri Ardiansyah ◽  
Resa Pramudita

Penggunaan peralatan tegangan tinggi pada konverter elektronik daya atau modul daya memiliki pengaruh terhadap sistem isolasi peralatan yang digunakan. Efek yang dihasilkan adalah pelepasan sebagian atau partial discharge (PD), dimana hal tersebut depengaruhi oleh bentuk tegangan, yang mana fenomena PD ini adalah awal mula terjadinya kegagalan dalam suatu peralatan. Pada penelitian ini dilakukan Pengukuran PD dengan mengacu pada Standar IEC 60270 yang menggunakan metode elektrik sebagai pengukuran yang digunakan untuk pengujian PD pada bahan PCB dengan alat ukur yang digunakan adalah RC detektor dan High Frequency Current Transformer (HFCT). Pengukuran PD dilakukan dengan membuat model elektroda yang digunakan pada pengujian untuk membuat sumber PD. Elektroda yang digunakan adalah model elektroda Homogen pelat-pelat. Pengujian pada PCB dilakukan untuk mengetahui karakteristik surface discharge pada disekitar antarmuka pelat-pelat elektroda. Parameter yang digunakan dalam pengukuran yaitu Partial Discharge Inception Voltage (PDIV), Partial Discharge Extinction Voltage (PDEV), Bentuk Gelombang PD, dan Pola Phasa PD.


Sign in / Sign up

Export Citation Format

Share Document