Improved Range Resolution Filters for Rectangular-Pulse Radar Systems

1980 ◽  
Vol AES-16 (2) ◽  
pp. 238-244 ◽  
Author(s):  
R. Evans ◽  
T. Fortmann
2006 ◽  
Vol 4 ◽  
pp. 79-83 ◽  
Author(s):  
M. Jelen ◽  
E. M. Biebl

Abstract. Remote measurement of breath and heartbeat is desirable in many situations. It avoids the discomfort resulting from electrodes applied on the skin for long-term patients or during sports acvtivities. Also, surveillance of high security areas or finding survivors of disasters are interesting applications. Common methods identify the movement of heart and thorax by using the range resolution provided by UWB pulse radar systems. In this paper a low-cost approach is presented, that is based on detection of movement by means of Doppler radar sensors. Combining three sensors working in the ISM bands at 433 MHz, 2.4 GHz and 24 GHz, the presence of persons was reliably detected and the frequency of breath and heartbeat was measured.


2003 ◽  
Author(s):  
Karl Wild ◽  
Sandro Ruhland ◽  
Sieghart Haedicke

1993 ◽  
Vol 4 (2) ◽  
pp. 175-181 ◽  
Author(s):  
Tobias Felhauer ◽  
Thomas Zimmermann ◽  
Peter Voigt ◽  
Paul Walter Baier

Author(s):  
Alifia Fitri Utami ◽  
Iswandi Iswandi ◽  
I Wayan Mustika

Abstract— Radar or radio detection and ranging has a basic function to detect and measure a target range. One of the latest developments is Software Defined Radio (SDR)-based radar. An example of SDR implementation is by using Universal Software Radio Peripheral (USRP) as hardware and GNU Radio Companion (GRC) as software. The simplest radar type is pulse radar in which system timing is crucial. Meanwhile, in pulse radar system implementation using USRP and GRC, there is an issue with the random processing time delay between communication protocol of USRP and computer running the GRC, which causes incorrect measurement. This research aims to analyze the random time delay in the pulse radar system implementation by using USRP and GRC to anticipate the effect of random time delay. Pulse radar systems implementation is administered by transmitting 128 bits of Barker code and performing correlation between transmitted and received radar signal. Research result shows that the random time delay can be anticipated by making the direct reception from radar transmitter to receiver as the reference in range calculation.


Author(s):  
R. D. Massaro ◽  
J. E. Anderson ◽  
J. D. Nelson ◽  
J. D. Edwards

Topographic Light Detection and Ranging (LiDAR) technology has advanced greatly in the past decade. Pulse repetition rates of terrestrial and airborne systems havemultiplied thus vastly increasing data acquisition rates. Geiger-mode and FLASH LiDAR have also become far more mature technologies. However, a new and relatively unknown technology is maturing rapidly: Frequency-Modulated Continuous Wave Laser Detection and Ranging (FMCW-LADAR). Possessing attributes more akin to modern radar systems, FMCWLADAR has the ability to more finely resolve objects separated by very small ranges. For tactical military applications (as described here), this can be a real advantage over single frequency, direct-detect systems. In fact, FMCW-LADAR can range resolve objects at 10<sup>−7</sup> to 10<sup>−6</sup> meter scales. FMCW-LADAR can also detect objects at greater range with less power. In this study, a FMCWLADAR instrument and traditional LiDAR instrument are compared. The co-located terrestrial scanning instruments were set up to perform simultaneous 3-D measurements of the given scene. Several targets were placed in the scene to expose the difference in the range resolution capabilities of the two instruments. The scans were performed at or nearly the same horizontal and vertical angular resolutions. It is demonstrated that the FMCW-LADAR surpasses the perfomance of the linear mode LiDAR scanner in terms of range resolution. Some results showing the maximum range acquisition are discussed but this was not studied in detail as the scanners’ laser powers differed by a small amount. Applications and implications of this technology are also discussed.


Sign in / Sign up

Export Citation Format

Share Document