Construction and Validation of a Plunge Electrode Array for Three-Dimensional Determination of Conductivity in the Heart

2008 ◽  
Vol 55 (2) ◽  
pp. 626-635 ◽  
Author(s):  
D.A. Hooks ◽  
M.L. Trew
1984 ◽  
Vol 30 (9) ◽  
pp. 1477-1488 ◽  
Author(s):  
W R Matson ◽  
P Langlais ◽  
L Volicer ◽  
P H Gamache ◽  
E Bird ◽  
...  

Abstract Coulometric electrodes in series have been used with liquid chromatography with electrochemical detection to increase selectivity and resolution for the direct analysis of tissue neurotransmitters. Use of three coulometric sensors for electrochemical modification, selectivity, and peak identification has been expanded into "gate" cells of three or four coulometric electrodes that allow elimination of all electrochemically irreversible substances, and "array" cells of up to 15 coulometric electrodes for separation of co-eluting compounds by their current/voltage characteristics. On-column sensitivity of the sensor arrays is 0.4 to 4 pg. Gate cell selectivity favors electrochemically reversible compounds over irreversible ones, e.g., 3-methoxy-4-hydroxyphenylglycol vs ascorbate, by a factor of up to 10(4). Resolution across the multi-electrode array cells allows separation of co-eluting compounds with half-wave potentials differing by as little as 30 to 40 mV. Cells with three to 15 electrodes have been used to measure monoamines and metabolites in brain; monoamines directly in serum filtrate; and the state of oxidation of 5-hydroxytryptamine and 5-hydroxytryptophan in cerebrospinal fluid of patients with Alzheimer's disease.


Author(s):  
M. Boublik ◽  
W. Hellmann ◽  
F. Jenkins

The present knowledge of the three-dimensional structure of ribosomes is far too limited to enable a complete understanding of the various roles which ribosomes play in protein biosynthesis. The spatial arrangement of proteins and ribonuclec acids in ribosomes can be analysed in many ways. Determination of binding sites for individual proteins on ribonuclec acid and locations of the mutual positions of proteins on the ribosome using labeling with fluorescent dyes, cross-linking reagents, neutron-diffraction or antibodies against ribosomal proteins seem to be most successful approaches. Structure and function of ribosomes can be correlated be depleting the complete ribosomes of some proteins to the functionally inactive core and by subsequent partial reconstitution in order to regain active ribosomal particles.


2013 ◽  
Vol 19 (S5) ◽  
pp. 58-61 ◽  
Author(s):  
Mino Yang ◽  
Jun-Ho Lee ◽  
Hee-Goo Kim ◽  
Euna Kim ◽  
Young-Nam Kwon ◽  
...  

AbstractDistribution of wax in laser printer toner was observed using an ultra-high-voltage (UHV) and a medium-voltage transmission electron microscope (TEM). As the radius of the wax spans a hundred to greater than a thousand nanometers, its three-dimensional recognition via TEM requires large depth of focus (DOF) for a volumetric specimen. A tomogram with a series of the captured images would allow the determination of their spatial distribution. In this study, bright-field (BF) images acquired with UHV-TEM at a high tilt angle prevented the construction of the tomogram. Conversely, the Z-contrast images acquired by the medium-voltage TEM produced a successful tomogram. The spatial resolution for both is discussed, illustrating that the image degradation was primarily caused by beam divergence of the Z-contrast image and the combination of DOF and chromatic aberration of the BF image from the UHV-TEM.