Determination of the Signal-To-Noise Ratio Enhancement in Comprehensive Three-Dimensional Gas Chromatography

Author(s):  
Timothy J. Trinklein ◽  
Cable G. Warren ◽  
Robert E. Synovec
Author(s):  
David A. Grano ◽  
Kenneth H. Downing

The retrieval of high-resolution information from images of biological crystals depends, in part, on the use of the correct photographic emulsion. We have been investigating the information transfer properties of twelve emulsions with a view toward 1) characterizing the emulsions by a few, measurable quantities, and 2) identifying the “best” emulsion of those we have studied for use in any given experimental situation. Because our interests lie in the examination of crystalline specimens, we've chosen to evaluate an emulsion's signal-to-noise ratio (SNR) as a function of spatial frequency and use this as our critereon for determining the best emulsion.The signal-to-noise ratio in frequency space depends on several factors. First, the signal depends on the speed of the emulsion and its modulation transfer function (MTF). By procedures outlined in, MTF's have been found for all the emulsions tested and can be fit by an analytic expression 1/(1+(S/S0)2). Figure 1 shows the experimental data and fitted curve for an emulsion with a better than average MTF. A single parameter, the spatial frequency at which the transfer falls to 50% (S0), characterizes this curve.


2018 ◽  
Vol 53 (2) ◽  
pp. 245-259
Author(s):  
Gary S LeMay ◽  
Davood Askari

Out-of-autoclave materials have long been an established material system for secondary structural applications; however, recent advancements in material properties allow for more advanced structural applications. Even though certain out-of-autoclave properties have achieved parity with autoclaved cured materials, out-of-autoclave materials are cured at reduced temperatures and pressures resulting in less compaction and homogeneity. The consequence is extraneous ultrasonic signals, due to internal reflections and refractions that cause attenuation, potentially masking defects leading to unidentifiable indications. Advanced algorithms were developed to improve the signal to noise ratio between constituents of similar acoustic impedance in bonded out-of-autoclave carbon fiber reinforced polymer assemblies. Conventional ultrasonic nondestructive testing techniques and analysis software cannot consistently achieve signal to noise ratios that meet quantifiable rejection thresholds of accurately sized peel ply inserts at the bonded interface of composite assemblies. Ultrasonic pulse echo with full waveform capture was used to inspect a reference standard with peel ply inserts placed between the adhesive and three-dimensional-woven fabric preform. The ultrasonic signal was produced by a 64 element array transducer with a central frequency of 2.8 MHz. Waveform post-acquisition analysis with post processing software was used to analyze and enhance the signal response between the peel ply and the bondline resulting in the final algorithm. To verify the results, the signal to noise ratio of each insert was calculated for both the raw and processed data. As the measure of detectability, the method relies on principles of statistical measurement to provide an industry standard signal to noise response of 3:1.


2020 ◽  
Vol 10 (6) ◽  
pp. 1930
Author(s):  
Chengkun Fu ◽  
Huaibin Zheng ◽  
Gao Wang ◽  
Yu Zhou ◽  
Hui Chen ◽  
...  

Three-dimensional (3D) imaging under the condition of weak light and low signal-to-noise ratio is a challenging task. In this paper, a 3D imaging scheme based on time-correlated single-photon counting technology is proposed and demonstrated. The 3D imaging scheme, which is composed of a pulsed laser, a scanning mirror, single-photon detectors, and a time-correlated single-photon counting module, employs time-correlated single-photon counting technology for 3D LiDAR (Light Detection and Ranging). Aided by the range-gated technology, experiments show that the proposed scheme can image the object when the signal-to-noise ratio is decreased to −13 dB and improve the structural similarity index of imaging results by 10 times. Then we prove the proposed scheme can image the object in three dimensions with a lateral imaging resolution of 512 × 512 and an axial resolution of 4.2 mm in 6.7 s. At last, a high-resolution 3D reconstruction of an object is also achieved by using the photometric stereo algorithm.


Geophysics ◽  
1970 ◽  
Vol 35 (1) ◽  
pp. 24-32 ◽  
Author(s):  
Bibhu P. Dash ◽  
K. Ahmed Obaidullah

A seismic trace may be represented as the sum of a signal and noise series. Each of the series may further be represented by convolution of a finite wavelet and a random series. With this representation, and provided that the signal and noise are uncorrelated, it is possible, in theory, to extract signal and noise statistics from two adjacent traces of a reflection seismogram. Some experiments are shown on model seismic traces, and it is shown that within the time‐duration of the seismic wavelet, the estimates of signal and noise statistics are reasonable for low signal‐to‐noise ratio. There remains, however, the problem of determining the optimum time lengths of the estimates.


2011 ◽  
Vol 284-286 ◽  
pp. 2251-2254
Author(s):  
Zhao Gang Nie ◽  
Xin Zhong Li ◽  
Yu Ping Tai ◽  
Ki Soo Lim ◽  
Myeongkyu Lee

The feasibility of three-dimensional optical bit memory is demonstrated by using the change of fluorescence and refractive index in Sm(DBM)3Phen-doped and un-doped Poly(methyl methacrylate). After a femtosecond pulsed laser irradiation, a refractive-index bit and a fluorescent bit can be formed at the same position inside the bulk sample. Multilayer patterns recorded by tightly focusing the pulsed laser beam were read out by a reflection-type fluorescent confocal microscope, which can detect the reflection signal and also the fluorescent signal of the stored bits. The signal-to-noise ratio via the two retrieval modes was compared as a function of recording depth. The stored bits were retrieved with a high signal-to-noise ratio in the absence of any crosstalk and the detection of the fluorescent signal enables retrieval of the stored bits with a higher S/N ratio.


1989 ◽  
Vol 35 (5) ◽  
pp. 874-878 ◽  
Author(s):  
F Moussa ◽  
L Dufour ◽  
J R Didry ◽  
P Aymard

Abstract By optimizing the conditions for determining trans-phylloquinone and its metabolite, K-2,3-epoxide, in serum through a two-step HPLC process combined with fluorometric detection after coulometric reduction, we have been able to develop a method applicable to small volumes of serum (200 to 500 microL). The limit of detection (signal-to-noise ratio of 3) was 15 ng/L for trans-phylloquinone, 30 ng/L for K-2,3-epoxide. The trans-phylloquinone concentrations measured by this method in serum from 82 children, ages one to six years, whose results were normal for overall coagulation tests, ranged from 40 to 880 ng/L (median 175 ng/L). We discuss these findings and compare them with vitamin K1(20) values reported for adults.


Sign in / Sign up

Export Citation Format

Share Document