Energy-Saving Project of 5500-HP 13-kV Wound Rotor Induction Motor on a Kiln ID Fan Using a Low-Voltage Slip Power Recovery Drive—A Case Study

2017 ◽  
Vol 53 (6) ◽  
pp. 5997-6001 ◽  
Author(s):  
Doug Phares ◽  
Tim Ruegg ◽  
Kelly Fishel
Electricity ◽  
2021 ◽  
Vol 2 (1) ◽  
pp. 91-109
Author(s):  
Julian Wruk ◽  
Kevin Cibis ◽  
Matthias Resch ◽  
Hanne Sæle ◽  
Markus Zdrallek

This article outlines methods to facilitate the assessment of the impact of electric vehicle charging on distribution networks at planning stage and applies them to a case study. As network planning is becoming a more complex task, an approach to automated network planning that yields the optimal reinforcement strategy is outlined. Different reinforcement measures are weighted against each other in terms of technical feasibility and costs by applying a genetic algorithm. Traditional reinforcements as well as novel solutions including voltage regulation are considered. To account for electric vehicle charging, a method to determine the uptake in equivalent load is presented. For this, measured data of households and statistical data of electric vehicles are combined in a stochastic analysis to determine the simultaneity factors of household load including electric vehicle charging. The developed methods are applied to an exemplary case study with Norwegian low-voltage networks. Different penetration rates of electric vehicles on a development path until 2040 are considered.


2006 ◽  
Vol 14 (2) ◽  
pp. 185-193 ◽  
Author(s):  
R. Gabbrielli ◽  
C. Medeot ◽  
D. Miconi

Energies ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2776
Author(s):  
Xin Ye ◽  
Jun Lu ◽  
Tao Zhang ◽  
Yupeng Wang ◽  
Hiroatsu Fukuda

Space cooling is currently the fastest-growing end-user in buildings. The global warming trend combined with increased population and economic development will lead to accelerated growth in space cooling in the future, especially in China. The hot summer and cold winter (HSCW) zone is the most densely populated and economically developed region in China, but with the worst indoor thermal environment. Relatively few studies have been conducted on the actual measurements in the optimization of insulation design under typical intermittent cooling modes in this region. This case study was conducted in Chengdu—the two residences selected were identical in design, but the south bedroom of the case study residence had interior insulation (inside insulation on all opaque interior surfaces of a space) retrofitted in the bedroom area in 2017. In August 2019, a comparative on-site measurement was done to investigate the effect of the retrofit work under three typical intermittent cooling patterns in the real-life scenario. The experimental result shows that interior insulation provides a significant improvement in energy-saving and the indoor thermal environment. The average energy savings in daily cooling energy consumption of the south bedroom is 42.09%, with the maximum reaching 48.91%. In the bedroom with interior insulation retrofit, the indoor temperature is closer to the set temperature and the vertical temperature difference is smaller during the cooling period; when the air conditioner is off, the room remains a comfortable temperature for a slightly longer time.


Author(s):  
B. Asad ◽  
T. Vaimann ◽  
A. Belahcen ◽  
A. Kallaste ◽  
A. Rassolkin ◽  
...  
Keyword(s):  

Author(s):  
R. Senthinathan ◽  
A. Mehra ◽  
M. Mahalingam ◽  
Y. Doi ◽  
H. Astrain
Keyword(s):  