Theoretical Investigation on the Linear Location Algorithm of the Magnetic Gradient Tensor Ranging by Use of cuboid Tri-Axial Magnetometer Array

2021 ◽  
pp. 1-1
Author(s):  
Huang Yu ◽  
Wan Bo-wen ◽  
Wu Li-hua
2021 ◽  
pp. 1-1
Author(s):  
Lei Xu ◽  
Ning Zhang ◽  
Ming Chang ◽  
Huadong Chen ◽  
Chunsheng Lin ◽  
...  

2021 ◽  
Vol 2021 ◽  
pp. 1-13
Author(s):  
Lei Xu ◽  
Ning Zhang ◽  
Liqing Fang ◽  
Huadong Chen ◽  
Pengfei Lin ◽  
...  

The magnetic gradient full-tensor measurement system is diverse, and the magnetometer array structure is complex. Aimed at the problem, seven magnetic gradient full-tensor measurement system models are studied in detail. The full-tensor measurement theories of the tensor measurement arrays are analyzed. Under the same baseline distance, the magnetic dipole model is used to simulate the measurement system. Based on different measurement systems, the paper quantitatively compares and analyzes the error of the structure. A more optimized magnetic gradient full-tensor measurement system is suggested. The simulation results show that the measurement accuracy of the planar measurement system is slightly higher than that of the stereo measurement system. Among them, the cross-shaped and square measurement systems have relatively smaller structural errors and higher measurement accuracy.


2021 ◽  
Vol 70 ◽  
pp. 1-14
Author(s):  
Qingzhu Li ◽  
Zhiyong Shi ◽  
Zhining Li ◽  
Hongbo Fan ◽  
Guang Zhang

Sensors ◽  
2020 ◽  
Vol 20 (5) ◽  
pp. 1290
Author(s):  
Youyu Yan ◽  
Yan Ma ◽  
Jianguo Liu

When using the technique of magnetic gradient tensor measurements to obtain the position of magnetic objects, calibration of the magnetic tensor gradiometer plays a pivotal role in precisely locating the target, and extensive research has been carried out on this up to now. However, previous studies have always lacked sufficient discussion on the position error of magnetometers in magnetic tensor gradiometers caused by inaccurate installment of magnetometers. In this paper, we analyze and correct this position error based on a magnetic dipole source. The result of the simulation exemplifies that the magnetometer’s position error will affect the locating accuracy and, therefore, it is worth correcting this error. The relationship between position error and magnetic gradient tensor components is established, followed by an error correction method based on this relationship. Simulations illustrate that this method can effectively decrease the effect caused by the position error of magnetometers and improve the locating performance with locating error and magnetic moment errors dropping from 2 to 0.2 m and 6 × 10 5 A ⋅ m 2 to 5 × 10 4 A ⋅ m 2 , respectively.


Geophysics ◽  
2017 ◽  
Vol 82 (6) ◽  
pp. WB21-WB28 ◽  
Author(s):  
Zhengyong Ren ◽  
Chaojian Chen ◽  
Jingtian Tang ◽  
Huang Chen ◽  
Shuanggui Hu ◽  
...  

A closed-form formula is developed for the full magnetic gradient tensor of a polyhedral body with a homogeneous magnetization vector. It is based on the direct derivative technique on the closed form of the magnetic field. These analytical expressions are implemented into an easy-to-use C++ package which simultaneously calculates the magnetic potential, the magnetic field, and the full magnetic gradient tensor for magnetic targets. Modern unstructured tetrahedral grids are adopted to represent the polyhedral body so that our code can deal with arbitrarily complicated magnetic targets. A prismatic body is tested to verify the accuracies of our closed-form formula. Excellent agreements are obtained between our closed-form solutions and solutions of a prismatic magnetic body with differences up to machine precision. A pipeline model is used to demonstrate its capability to deal with complicated magnetic targets. This C++ code is freely available to the magnetic exploration community.


2019 ◽  
Vol 50 (6) ◽  
pp. 600-612
Author(s):  
Jinpeng Li ◽  
Yingtang Zhang ◽  
Hongbo Fan ◽  
Zhining Li ◽  
Min Liu

Sign in / Sign up

Export Citation Format

Share Document