Design for a high-resolution small-animal SPECT system using pixellated Si(Li) detectors for in vivo /sup 125/I imaging

2005 ◽  
Vol 52 (1) ◽  
pp. 174-180 ◽  
Author(s):  
W.-S. Choong ◽  
W.W. Moses ◽  
C.S. Tindall ◽  
P.N. Luke
2012 ◽  
Vol 2012 ◽  
pp. 1-6 ◽  
Author(s):  
Hirofumi Fujii ◽  
Masayuki Yamaguchi ◽  
Kazumasa Inoue ◽  
Yasuko Mutou ◽  
Masashi Ueda ◽  
...  

Purpose. We aimed to clearly visualize heterogeneous distribution of hypoxia-inducible factor 1α(HIF) activity in tumor tissuesin vivo.Methods. We synthesized of125I-IPOS, a125I labeled chimeric protein probe, that would visualize HIF activity. The biodistribution of125I-IPOS in FM3A tumor-bearing mice was evaluated. Then, the intratumoral localization of this probe was observed by autoradiography, and it was compared with histopathological findings. The distribution of125I-IPOS in tumors was imaged by a small animal SPECT/CT scanner. The obtainedin vivoSPECT-CT fusion images were compared withex vivoimages of excised tumors. Fusion imaging with MRI was also examined.Results.125I-IPOS well accumulated in FM3A tumors. The intratumoral distribution of125I-IPOS by autoradiography was quite heterogeneous, and it partially overlapped with that of pimonidazole. High-resolution SPECT-CT fusion images successfully demonstrated the heterogeneity of125I-IPOS distribution inside tumors. SPECT-MRI fusion images could give more detailed information about the intratumoral distribution of125I-IPOS.Conclusion. High-resolution SPECT images successfully demonstrated heterogeneous intratumoral distribution of125I-IPOS. SPECT-CT fusion images, more favorably SPECT-MRI fusion images, would be useful to understand the features of heterogeneous intratumoral expression of HIF activityin vivo.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Jan P. Janssen ◽  
Jan V. Hoffmann ◽  
Takayuki Kanno ◽  
Naoko Nose ◽  
Jan-Peter Grunz ◽  
...  

Abstract We aimed to investigate the image quality of the U-SPECT5/CT E-Class a micro single-photon emission computed tomography (SPECT) system with two large stationary detectors for visualization of rat hearts and bones using clinically available 99mTc-labelled tracers. Sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR) of the small-animal SPECT scanner were investigated in phantom studies using an ultra-high-resolution rat and mouse multi-pinhole collimator (UHR-RM). Point source, hot-rod, and uniform phantoms with 99mTc-solution were scanned for high-count performance assessment and count levels equal to animal scans, respectively. Reconstruction was performed using the similarity-regulated ordered-subsets expectation maximization (SROSEM) algorithm with Gaussian smoothing. Rats were injected with ~ 100 MBq [99mTc]Tc-MIBI or ~ 150 MBq [99mTc]Tc-HMDP and received multi-frame micro-SPECT imaging after tracer distribution. Animal scans were reconstructed for three different acquisition times and post-processed with different sized Gaussian filters. Following reconstruction, CNR was calculated and image quality evaluated by three independent readers on a five-point scale from 1 = “very poor” to 5 = “very good”. Point source sensitivity was 567 cps/MBq and radioactive rods as small as 1.2 mm were resolved with the UHR-RM collimator. Collimator-dependent uniformity was 55.5%. Phantom CNR improved with increasing rod size, filter size and activity concentration. Left ventricle and bone structures were successfully visualized in rat experiments. Image quality was strongly affected by the extent of post-filtering, whereas scan time did not have substantial influence on visual assessment. Good image quality was achieved for resolution range greater than 1.8 mm in bone and 2.8 mm in heart. The recently introduced small animal SPECT system with two stationary detectors and UHR-RM collimator is capable to provide excellent image quality in heart and bone scans in a rat using standardized reconstruction parameters and appropriate post-filtering. However, there are still challenges in achieving maximum system resolution in the sub-millimeter range with in vivo settings under limited injection dose and acquisition time.


2020 ◽  
Author(s):  
Jan V Hoffmann ◽  
Jan P Janssen ◽  
Takayuki Kanno ◽  
Takayuki Shibutani ◽  
Masahisa Onoguchi ◽  
...  

Abstract Background: Small-animal single-photon emission computed tomography (SPECT) systems with multi-pinhole collimation and large stationary detectors have advantages compared to systems with moving small detectors. These systems benefit from less labour-intensive maintenance and quality control as fewer prone parts are moving, higher accuracy for focused scans and maintaining high resolution with increased sensitivity due to focused pinholes on the field of view. This study aims to investigate the performance of a novel ultra-high-resolution scanner with two-detector-configuration (U-SPECT5-E) and to compare its image quality to a conventional micro-SPECT system with three stationary detectors (U-SPECT+).Methods: The new U-SPECT5-E with two stationary detectors was used for acquiring data with 99mTc-filled point source, hot-rod and uniformity phantoms to analyse sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR). Three dedicated multi-pinhole mouse collimators with 75 pinholes each and 0.25-, 0.60- and 1.00-mm pinholes for extra ultra-high resolution (XUHR-M), general-purpose (GP-M) and ultra-high sensitivity (UHS-M) imaging were examined. For CNR analysis, four different activity ranges representing low- and high-count settings were investigated for all three collimators. The experiments for the performance assessment were repeated with the same GP-M collimator in the three-detector U-SPECT+ for comparison. Results: Peak sensitivity was 237 cps/MBq (XUHR-M), 847 cps/MBq (GP-M), 2054 cps/MBq (UHS-M) for U-SPECT5-E and 1710 cps/MBq (GP-M) for U-SPECT+. In the visually analysed sections of the reconstructed mini Derenzo phantom, rods as small as 0.35 mm (XUHR-M), 0.50 mm (GP-M) for the two-detector as well as the three-detector SPECT and 0.75 mm (UHS-M) were resolved. Uniformity for maximum resolution recorded 40.7% (XUHR-M), 29.1% (GP-M, U-SPECT5-E), 16.3% (GP-M, U-SPECT+) and 23.0% (UHS-M), respectively. UHS-M reached highest CNR values for low-count images; for rods smaller than 0.45 mm, acceptable CNR was only achieved by XUHR-M. GP-M was superior for imaging rods sized from 0.60-1.50 mm for intermediate activity concentrations. U-SPECT5-E and U-SPECT+ both provided comparable CNR.Conclusions: While uniformity and sensitivity are negatively affected by the absence of a third detector, the investigated U-SPECT5-E system with two stationary detectors delivers excellent spatial resolution and CNR comparable to the performance of an established three-detector-setup.


2021 ◽  
Author(s):  
Annunziata D'Elia ◽  
Andrea Soluri ◽  
Filippo Galli ◽  
Sara Schiavi ◽  
Giselda De Silva ◽  
...  

Abstract The utility of animal models in preclinical research has been increasing by the availability of methods for in vivo imaging. In particular, techniques like single photon emission computed tomography (SPECT) show high potential, which is usually limited by spatial resolution. This represents an important parameter influencing scanner design, given the small size of the anatomical structures to be investigated. The purpose of the present work was to assess the performance of a scintigraphic system with improved spatial resolution based on our previous detector by applying the Super Spatial Resolution (SSR). Our dual-head SPECT system is composed of gamma cameras based on the Hamamatsu H13700 position-sensitive photomultiplier tube (PSPMT). In each detector head, the PSPMT is coupled to a 28×28 array of CRY018 scintillation crystals. The pure Tungsten parallel square hole collimator ensures the position sensitivity, and a dedicated resistive chain readout so as an ADC board have been proprietary designed. To finalize the mechanical development of the SSR-SPECT system several tests were carried out. Based on the results obtained in the test phase, a partial review of the mechanical design was performed. Then a dedicated machine handling software was developed, and in particular, a kinematic software debugging and testing was assessed. Finally, several experiments were carried out by using Derenzo phantoms and capillaries filled with radioactive sources. Finally, the performance of our system was evaluated performing small animal imaging studies. The SPECT spatial resolution was experimentally determined to be about 1.6 mm. We reach a resolution of 1.18 mm by applying the SSR based on two images. The results of this study demonstrated the good capability of the system as a suitable tool for preclinical imaging especially in fields like neuroscience for the study of small brain structures.