Notice of Removal: In-vivo 3D cardiac vector flow imaging — A comparison between ultrasound and phase-contrast MRI

Author(s):  
Morten Wigen ◽  
Alfonso Rodriguez-Molares ◽  
Tore Bjastad ◽  
Marius Eriksen ◽  
Knut Hakon Stensath ◽  
...  
2003 ◽  
Vol 49 (2) ◽  
pp. 315-321 ◽  
Author(s):  
J�rg U.G. Streif ◽  
Volker Herold ◽  
Michael Szimtenings ◽  
Titus E. Lanz ◽  
Matthias Nahrendorf ◽  
...  

2008 ◽  
Vol 28 (3) ◽  
pp. 655-663 ◽  
Author(s):  
Petter Dyverfeldt ◽  
John-Peder Escobar Kvitting ◽  
Andreas Sigfridsson ◽  
Jan Engvall ◽  
Ann F. Bolger ◽  
...  

2017 ◽  
Vol 48 (1) ◽  
pp. 283-289 ◽  
Author(s):  
Uday Krishnamurthy ◽  
Brijesh K. Yadav ◽  
Pavan K. Jella ◽  
Ewart Mark Haacke ◽  
Edgar Hernandez-Andrade ◽  
...  

2008 ◽  
Vol 41 ◽  
pp. S295
Author(s):  
Umberto Morbiducci ◽  
Raffaele Ponzini ◽  
Giovanna Rizzo ◽  
Marcello Cadioli ◽  
Diana Massai ◽  
...  

2018 ◽  
Vol 46 (1) ◽  
pp. 98-106 ◽  
Author(s):  
Jérémie Bettoni ◽  
Gwénaël Pagé ◽  
Anne-Virginie Salsac ◽  
Jean-Marc Constans ◽  
Sylvie Testelin ◽  
...  

2004 ◽  
Vol 52 (2) ◽  
pp. 286-295 ◽  
Author(s):  
Mary T. Draney ◽  
Frank R. Arko ◽  
Marcus T. Alley ◽  
Michael Markl ◽  
Robert J. Herfkens ◽  
...  

2021 ◽  
Vol 18 (1) ◽  
Author(s):  
Per Kristian Eide ◽  
Lars Magnus Valnes ◽  
Erika Kristina Lindstrøm ◽  
Kent-Andre Mardal ◽  
Geir Ringstad

Abstract Background Several central nervous system diseases are associated with disturbed cerebrospinal fluid (CSF) flow patterns and have typically been characterized in vivo by phase-contrast magnetic resonance imaging (MRI). This technique is, however, limited by its applicability in space and time. Phase-contrast MRI has yet to be compared directly with CSF tracer enhanced imaging, which can be considered gold standard for assessing long-term CSF flow dynamics within the intracranial compartment. Methods Here, we studied patients with various CSF disorders and compared MRI biomarkers of CSF space anatomy and phase-contrast MRI at level of the aqueduct and cranio-cervical junction with dynamic intrathecal contrast-enhanced MRI using the contrast agent gadobutrol as CSF tracer. Tracer enrichment of cerebral ventricles was graded 0–4 by visual assessment. An intracranial pressure (ICP) score was used as surrogate marker of intracranial compliance. Results The study included 94 patients and disclosed marked variation of CSF flow measures across disease categories. The grade of supra-aqueductal reflux of tracer varied, with strong reflux (grades 3–4) in half of patients. Ventricular tracer reflux correlated with stroke volume and aqueductal CSF pressure gradient. CSF flow in the cerebral aqueduct was retrograde (from 4th to 3rd ventricle) in one third of patients, with estimated CSF net flow volume about 1.0 L/24 h. In the cranio-cervical junction, net flow was cranially directed in 78% patients, with estimated CSF net flow volume about 4.7 L/24 h. Conclusions The present observations provide in vivo quantitative evidence for substantial variation in direction and magnitude of CSF flow, with re-direction of aqueductal flow in communicating hydrocephalus, and significant extra-cranial CSF production. The grading of ventricular reflux of tracer shows promise as a clinical useful method to assess CSF flow pattern disturbances in patients. Graphic abstract


Sign in / Sign up

Export Citation Format

Share Document