Computation of Transient Voltages on Wind Turbines on Frequency-Dependent Soil Caused by Lightning Strikes

Author(s):  
Walter L. M. de Azevedo ◽  
Wagner C. da Silva ◽  
Anderson R. J. de Araujo ◽  
Jose Pissolato Filho
2020 ◽  
Vol 11 (7-2020) ◽  
pp. 66-72
Author(s):  
Liubov A. Belova ◽  

The earth-termination system for towers of ground-based wind turbines in addition to protective and functional grounding provides lightning protection grounding, which is especially important since the wind turbine is susceptible to lightning strikes. If insufficient protective measures are taken, the risk of damage to a wind turbine due to a lightning strike increases. Therefore, a well-thought-out built-in grounding system for wind turbine towers is needed, which would function as necessary and guarantee long-term mechanical strength and corrosion resistance. The configuration of grounding systems for wind turbines is discussed in IEC 61400-24, which deals with the topic of lightning protection for wind turbines, including detailed information on the choice of lightning protection measures and surge protection. It is advisable to create a lightning protection concept at the initial stage of planning a wind turbine in order to avoid later costly repairs and retrofitting.


Author(s):  
Riccardo Torchio ◽  
Martino Nicora ◽  
Daniele Mestriner ◽  
Massimo Brignone ◽  
Renato Procopio ◽  
...  

2020 ◽  
Author(s):  
Gerhard Diendorfer

<p>Upward lightning triggered by elevated objects, such as wind turbines (WT), may increase significantly the number of lightning strikes to these objects. In the recently publishes 2<sup>nd</sup> edition of the international standard IEC 61400-24 an environmental factor C<sub>DWL</sub> for winter lightning conditions was introduced to account for this additional lightning risk in the lightning exposure assessment of a WT. Values for C<sub>DWL</sub> should be 4 (in medium winter lightning activity areas) or 6 (high activity areas) or even higher in special cases. The main challenge is to get reliable data about the winter lightning activity for a given region and for first estimates maps of winter lightning activity for the continents are given in IEC 62400-24, Annex B.</p><p>A different approach is used in this contribution. As there is already a high number of WT installed in Europe, we have investigated the number (percentage) of existing WT that was at least struck one time in the winter periods of 2017/18 an 2018/19 based on data of the EUCLID lightning location system.</p><p>We have extracted the locations of 10.225 WT sites in Europe in the area from 45°N - 50°N and 10°W -30°E form OpenStreetMap database. Then we checked if there were any lightning strikes located by EUCLID within a 0.003° circular area (is about a 300 m radius) around each of these turbines during the cold season (October to April) in 2017/18 and 2018/2019, respectively. Out of the 10.225 WT 1.131 (11,1 %) and 913 (8,9 %) have been struck by lightning in cold season 2017/18 and 2018/19, respectively. It is worth noting, that only 101 WT (1%) were struck in both seasons, indicating that it is more a dependency on regional meteorological conditions changing from year to year, rather than on a specific group of WT. EUCLID detected flashes are likely to represent only about one half of the real occurring upward flashes from the WT. ICC<sub>Only</sub> type upward lightning, which are discharges with current waveforms not followed by any return strokes are typically not detected by lightning location systems, and on instrumented towers this type of discharges makes up about 50% of all upward lightning. But there is a high chance, that a large fraction of this ICC<sub>Only</sub> discharges were triggered by the same WT, where EUCLID detected some strokes.</p><p>In terms of dependency of the altitude of the WT site above sea level we observe a clear increase of probability of WT lightning with increasing altitude. About 10 % (29/315) of the 315 WT at altitudes up to 50 m ASL are struck by lightning increasing to almost 50 % (15/31) for WT at sites of 950 to 1000 m altitudes ASL. No clear trend is observed for higher altitudes, likely due to the low number of WT above 1000 m.</p><p>The obtained 10 % of the WTs triggering at least one upward lighting per cold season demonstrates the high probability of lightning to WT and emphasizes the need of proper protection of the WTs mechanical structure (rotor blades) as well as the entire electrical installation.</p>


2021 ◽  
Vol 194 ◽  
pp. 107103
Author(s):  
T.F.G. Pascoalato ◽  
A.R.J. de Araújo ◽  
S. Kurokawa ◽  
J. Pissolato Filho

2021 ◽  
Vol 141 (5) ◽  
pp. 400-401
Author(s):  
Masaru Ishii ◽  
Mikihisa Saito ◽  
Daisuke Natsuno

2011 ◽  
Vol 2011 ◽  
pp. 1-6 ◽  
Author(s):  
J. G. Fantidis ◽  
C. Potolias ◽  
D. V. Bandekas

Wind turbines are becoming widely used as they are an environmentally friendly way for energy production without emissions; however, they are exposed to a corrosive environment. In addition, as wind turbines typically are the tallest structures in the surrounding area of a wind farm, it is expected that they will attract direct lightning strikes several times during their operating life. The purpose of this paper is to show that the radiography with a transportable unit is a solution to find defects in the wind turbine blade and reduce the cost of inspection. A transportable neutron radiography system, incorporating an Sb–Be source, has been simulated using the MCNPX code. The simulated system has a wide range of radiography parameters.


Machines ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 9
Author(s):  
Takuto Matsui ◽  
Kazuo Yamamoto ◽  
Jun Ogata

There have been many reports of damage to wind turbine blades caused by lightning strikes in Japan. In some of these cases, the blades struck by lightning continue to rotate, causing more serious secondary damage. To prevent such accidents, it is a requirement that a lightning detection system is installed on the wind turbine in areas where winter lightning occurs in Japan. This immediately stops the wind turbine if the system detects a lightning strike. Normally, these wind turbines are restarted after confirming soundness of the blade through visual inspection. However, it is often difficult to confirm the soundness of the blade visually for reasons such as bad weather. This process prolongs the time taken to restart, and it is one of the causes that reduces the availability of the wind turbines. In this research, we constructed a damage detection model for wind turbine blades using machine learning based on SCADA system data and, thereby, considered whether the technology automatically confirms the soundness of wind turbine blades.