The new rapid and accurate analytical HPLC‐ECD method for the determination of rosmarinic acid in meat products

2021 ◽  
Vol 86 (10) ◽  
pp. 4491-4499
Author(s):  
Urška Jurič ◽  
Mojca Slemnik ◽  
Mojca Škerget
1990 ◽  
Vol 73 (1) ◽  
pp. 54-57 ◽  
Author(s):  
Kurt Kolar

Abstract A colorimetric method for the determination of hydroxyproline as a measure of collagen in meat and meat products has been collaboratively studied in 18 laboratories. The method includes hydrolysis with sulfuric acid, oxidation with chloramine- T, and formation of a reddish purple complex with 4- dimethylaminobenzaldehyde. Five frozen and 3 freeze-dried samples were tested, ranging in content from 0.11 to 0.88% and from 0.39 to 4.0% hydroxyproline, respectively. The mean values of 2 identical samples were 0.245 and 0.251 %. The average recovery from a spiked sample was 96.1 %. The hydroxyproline content of a known sample (a mixture of 2 samples in the ratio 5:2) was calculated to 1.42%, which agrees well with the analytical result, 1.40%. In comparison with other collaborative studies, based on the ISO analytical method, the repeatability and reproducibility of this method agree well with the other results. This method was accepted as an official NMKL method by all national Committees, and has been adopted official first action by AOAC as an NMKLAOAC method.


1948 ◽  
Vol 31 (3) ◽  
pp. 646-652
Author(s):  
Charles F Poe ◽  
Frank A Lane
Keyword(s):  

1945 ◽  
Vol 10 (1) ◽  
pp. 60-65 ◽  
Author(s):  
COLONEL MAURICE W. HALE
Keyword(s):  

2018 ◽  
Vol 2018 ◽  
pp. 1-6 ◽  
Author(s):  
Babiker Yagoub Abdulkair ◽  
Amin O. Elzupir ◽  
Abdulaziz S. Alamer

An accurate IPC-UV method was developed and validated for the determination of nitrite (NI) and nitrate (NA) in meat products. The best separation was achieved on a phenyl-hexyl column (150 mm × 4.6 mm, 3 µm) with a mobile phase composed of 25% acetonitrile and 75% buffer (2 mM disodium hydrogen phosphate and 3 mM tetrabutylammonium bromide, pH = 4). Eluents were monitored at 205 nm. Linearity ranges were 1.86 × 10−6–7.5 µg·ml−1 and 0.09–5.0 µg·ml−1 for NI and NA, respectively. The correlation coefficients were greater than 0.999 for NI and NA. This method was applied to a number of processed meat products in Riyadh (n = 155). NI ranged from 1.78 to 129.69 mg·kg−1, and NA ranged from 0.76 to 96.64 mg·kg−1. Results showed extensive use of NI and NA; however, concentrations were within the legal limit of Saudi Arabia except for one sample. Further, the risk assessment and dietary exposure have been estimated for both NI and NA.


Sign in / Sign up

Export Citation Format

Share Document