Prevalence, risk factors and impact of posterior staphyloma diagnosed from wide‐field optical coherence tomography in Singapore adults with high myopia

Author(s):  
Feihui Zheng ◽  
Chee‐Wai Wong ◽  
Charumathi Sabanayagam ◽  
Yin‐Bun Cheung ◽  
Saiko Matsumura ◽  
...  
2021 ◽  
pp. 112067212110623
Author(s):  
Li-Hui Meng ◽  
Ming-Zhen Yuan ◽  
Xin-Yu Zhao ◽  
Wei-Hong Yu ◽  
You-Xin Chen

Background To investigate the features in the posterior pole of highly myopic (HM) eyes using a wide-field high-resolution swept source optical coherence tomography (SS OCT). Methods This observational cross-sectional study involved 262 eyes of 139 patients, who were diagnosed as HM and had consecutively been examined by SS OCT in the Ophthalmology Department of the Peking Union Medical College Hospital between March 2019 and December 2019. The characteristics of OCT images were documented and analyzed. Results In our study, SS OCT could demonstrate the entire layer of the choroid and detect the sclera in all eyes. The mean subfoveal retinal/choroidal/scleral thickness were 204.84 ± 119.86 μm, 92.80 ± 75.78 μm and 394.734 ± 123.09 μm, respectively. 138 eyes (52.67%) had posterior precortical vitreous pocket. Myopic foveoschisis was detected in 110 eyes (41.98%), and significantly associated with the presence of posterior staphyloma. 36 eyes (13.74%) had DSM in our study, of which 8 eyes (22.22%) showed a round dome, 16 (44.44%) were horizontal oval-shaped, 9 (25%) were vertical oval-shaped and 3 (8.34%) were oblique oval-shaped. Both SFCT and SFST were inversely and significantly associated with age and refractive errors. Macular neovascularization was significantly correlated with intrascleral vessels. Different deformation of the sclera and posterior staphyloma were vividly identified on SS OCT images. Conclusions This study provided a relatively comprehensive picture of posterior pole in HM eyes. Such good visualization of ocular fundus provided by wide-field SS OCT could be useful for the therapy option, disease condition monitoring and pathogenesis investigation.


2017 ◽  
Vol 96 (4) ◽  
pp. e515-e523 ◽  
Author(s):  
Tong Li ◽  
Xiaohan Wang ◽  
Yanping Zhou ◽  
Tonghui Feng ◽  
Meichun Xiao ◽  
...  

2016 ◽  
Vol 25 (5) ◽  
pp. e526-e530 ◽  
Author(s):  
Harsha L. Rao ◽  
Addepalli U. Kumar ◽  
Sampath R. Bonala ◽  
Kadam Yogesh ◽  
Bodduluri Lakshmi

2020 ◽  
pp. bjophthalmol-2020-317825
Author(s):  
Yonghao Li ◽  
Weibo Feng ◽  
Xiujuan Zhao ◽  
Bingqian Liu ◽  
Yan Zhang ◽  
...  

Background/aimsTo apply deep learning technology to develop an artificial intelligence (AI) system that can identify vision-threatening conditions in high myopia patients based on optical coherence tomography (OCT) macular images.MethodsIn this cross-sectional, prospective study, a total of 5505 qualified OCT macular images obtained from 1048 high myopia patients admitted to Zhongshan Ophthalmic Centre (ZOC) from 2012 to 2017 were selected for the development of the AI system. The independent test dataset included 412 images obtained from 91 high myopia patients recruited at ZOC from January 2019 to May 2019. We adopted the InceptionResnetV2 architecture to train four independent convolutional neural network (CNN) models to identify the following four vision-threatening conditions in high myopia: retinoschisis, macular hole, retinal detachment and pathological myopic choroidal neovascularisation. Focal Loss was used to address class imbalance, and optimal operating thresholds were determined according to the Youden Index.ResultsIn the independent test dataset, the areas under the receiver operating characteristic curves were high for all conditions (0.961 to 0.999). Our AI system achieved sensitivities equal to or even better than those of retina specialists as well as high specificities (greater than 90%). Moreover, our AI system provided a transparent and interpretable diagnosis with heatmaps.ConclusionsWe used OCT macular images for the development of CNN models to identify vision-threatening conditions in high myopia patients. Our models achieved reliable sensitivities and high specificities, comparable to those of retina specialists and may be applied for large-scale high myopia screening and patient follow-up.


2015 ◽  
Vol 08 (04) ◽  
pp. 1550012 ◽  
Author(s):  
Qinqin Zhang ◽  
Maureen Neitz ◽  
Jay Neitz ◽  
Ruikang K. Wang

Purpose: To provide a geographical map of choroidal thickness (CT) around the macular region among subjects with low, moderate and high myopia. Methods: 20 myopic subjects (n = 40 eyes) without other identified pathologies participated in this study: 20 eyes of ≤ 3 diopters (D) (low myopic), 10 eyes between -3 and -6D (moderate myopic), and 10 eyes of ≥ 6D (high myopic). The mean age of subjects was 30.2 years (± 7.6 years; range, 24 to 46 years). A 1050 nm spectral-domain optical coherence tomography (SD-OCT) system, operating at 120 kHz imaging rate, was used in this study to simultaneously capture 3D anatomical images of the choroid and measure intraocular length (IOL) in the subject. The 3D OCT images of the choroid were segmented into superior, inferior, nasal and temporal quadrants, from which the CT was measured, representing radial distance between the outer retinal pigment epithelium (RPE) layer and inner scleral border. Measurements were made within concentric regions centered at fovea centralis, extended to 5 mm away from fovea at 1 mm intervals in the nasal and temporal directions. The measured IOL was the distance from the anterior cornea surface to the RPE in alignment along the optical axis of the eye. Statistical analysis was performed to evaluate CT at each geographic region and observe the relationship between CT and the degree of myopia. Results: For low myopic eyes, the IOL was measured at 24.619 ± 0.016 mm. The CT (273.85 ± 49.01 μm) was greatest under fovea as is in the case of healthy eyes. Peripheral to the fovea, the mean CT decreased rapidly along the nasal direction, reaching a minimum of 180.65 ± 58.25μm at 5 mm away from the fovea. There was less of a change in thickness from the fovea in the temporal direction reaching a minimum of 234.25 ± 42.27 μm. In contrast to the low myopic eyes, for moderate and high myopic eyes, CTs were thickest in temporal region (where CT = 194.94 ± 27.28 and 163 ± 34.89 μm, respectively). Like the low myopic eyes, moderate and high myopic eyes had thinnest CTs in the nasal region (where CT = 100.84 ± 16.75 and 86.64 ± 42.6μm, respectively). High myopic eyes had the longest mean IOL (25.983 ± 0.021mm), while the IOL of moderate myopia was 25.413 ± 0.022 mm (**p < 0.001). The CT reduction rate was calculated at 31.28 μm/D (diopter) from low to moderate myopia, whilst it is 13.49 μm/D from moderate to high myopia. The similar tendency was found for the IOL reduction rate in our study: 0.265 mm/D from low to moderate myopia, and 0.137 mm/D from moderate to high myopia. Conclusion: The CT decreases and the IOL increases gradually with the increase of myopic condition. The current results support the theory that choroidal abnormality may play an important role in the pathogenesis of myopic degeneration.


Ophthalmology ◽  
2013 ◽  
Vol 120 (1) ◽  
pp. 169-174 ◽  
Author(s):  
Ninel Z. Gregori ◽  
Byron L. Lam ◽  
Giovanni Gregori ◽  
Sudarshan Ranganathan ◽  
Edwin M. Stone ◽  
...  

Diagnostics ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 658
Author(s):  
Federico Corvi ◽  
Federico Zicarelli ◽  
Matteo Airaldi ◽  
Salvatore Parrulli ◽  
Mariano Cozzi ◽  
...  

Background: To compare four different optical coherence tomography (OCT) devices for visualization of retinal and subretinal layers in highly myopic eyes. Methods: In this prospective, observational, cross-sectional study, consecutive patients with high myopia and control subjects were imaged by four OCT devices: Spectralis OCT2, PlexElite 2.0 100 kHz, PlexElite 2.0 200 kHz and the Canon Xephilio OCT-S1. The acquisition protocol for comparison consisted of single vertical and horizontal line scans centered on the fovea. Comparison between the devices in the extent of visible retina, presence of conjugate image or mirror artifacts, visibility of the sclerochoroidal interface and retrobulbar tissue. Results: 30 eyes with high myopia and 30 control subjects were analyzed. The visualized RPE length was significantly different between the OCT devices with Xephilio OCT-S1 imaging the largest extent (p < 0.0001). The proportion of eyes with conjugate image artifact was significantly higher with the Spectralis OCT (p < 0.0001), and lower with the PlexElite 200 kHz (p < 0.0001). No difference in visibility of the sclerochoroidal interface was noted among instruments. The retrobulbar tissue was visible in a higher proportion of eyes using swept-source PlexElite 100 kHz and 200 kHz (p < 0.007) compared to the other devices. Conclusions: In highly myopic eyes, the four OCT devices demonstrated significant differences in the extent of the retina imaged, in the prevalence of conjugate image artifact, and in the visualization of the retrobulbar tissue.


Sign in / Sign up

Export Citation Format

Share Document