scholarly journals Comparison between Widefield Optical Coherence Tomography Devices in Eyes with High Myopia

Diagnostics ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 658
Author(s):  
Federico Corvi ◽  
Federico Zicarelli ◽  
Matteo Airaldi ◽  
Salvatore Parrulli ◽  
Mariano Cozzi ◽  
...  

Background: To compare four different optical coherence tomography (OCT) devices for visualization of retinal and subretinal layers in highly myopic eyes. Methods: In this prospective, observational, cross-sectional study, consecutive patients with high myopia and control subjects were imaged by four OCT devices: Spectralis OCT2, PlexElite 2.0 100 kHz, PlexElite 2.0 200 kHz and the Canon Xephilio OCT-S1. The acquisition protocol for comparison consisted of single vertical and horizontal line scans centered on the fovea. Comparison between the devices in the extent of visible retina, presence of conjugate image or mirror artifacts, visibility of the sclerochoroidal interface and retrobulbar tissue. Results: 30 eyes with high myopia and 30 control subjects were analyzed. The visualized RPE length was significantly different between the OCT devices with Xephilio OCT-S1 imaging the largest extent (p < 0.0001). The proportion of eyes with conjugate image artifact was significantly higher with the Spectralis OCT (p < 0.0001), and lower with the PlexElite 200 kHz (p < 0.0001). No difference in visibility of the sclerochoroidal interface was noted among instruments. The retrobulbar tissue was visible in a higher proportion of eyes using swept-source PlexElite 100 kHz and 200 kHz (p < 0.007) compared to the other devices. Conclusions: In highly myopic eyes, the four OCT devices demonstrated significant differences in the extent of the retina imaged, in the prevalence of conjugate image artifact, and in the visualization of the retrobulbar tissue.

QJM ◽  
2020 ◽  
Vol 113 (Supplement_1) ◽  
Author(s):  
O M Abdelfatah ◽  
O A Salem ◽  
A I Elawamry ◽  
Y A Elzanklony

Abstract Background Glaucoma is an optic neuropathy that is characterized by the selective loss of retinal ganglion cells and their axons, which manifests as the loss of the retinal nerve fiber layer (RNFL). Numerous studies have shown that the extent of RNFL damage correlates with the severity of functional deficit in the visual field (VF), and that RNFL measurement by optical coherence tomography (OCT) has good sensitivity for the detection of glaucoma. Purpose To assess the prevalence of glaucoma among high myopic patients and the association between them using standard automated perimetry (SAP) and optical coherence tomography (OCT). Patients and Methods A prospective observational randomized cross sectional study included a total of 80 eyes with high myopia, in the period from November 2017 to April 2018. This cross sectional study included 44 subjects with 80 eyes regarding high myopia using the outpatient services of the Qlawoon Hospital, Cairo, who satisfied the inclusion and exclusion criteria between November 2017 and April 2018 aiming to determine the prevalence of glaucoma in high myopic patients. Results In our study, we depended on the following highly significant parameters in detection of prevalence of glaucoma among high myopic patients: Spherical equivalent median is -12, Vertical cup/disc ratio mean is 0.55, MD median of visual field is – 5.38, PSD mean of visual field is 3.53, GHT is 64.7% outside normal limits, 17.6% border line and 17.6% general reduction of sensitivity and RNFL thickness mean is; for average thickness is 86.37, for superior thickness is 90.06 and for inferior thickness is 82.68 a highly significant P-value. Conclusion Prevalence of glaucoma among our study group is 42.5% depending on Spherical equivalent median, Vertical cup/disc ratio mean, MD median of visual field, PSD mean of visual field, GHT and RNFL thickness.


Diagnostics ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 223
Author(s):  
Anna Nowińska ◽  
Edyta Chlasta-Twardzik ◽  
Michał Dembski ◽  
Klaudia Ulfik-Dembska ◽  
Edward Wylęgała

This study focused on defining the characteristic features of keratometry and pachymetry elevation maps based on swept source optical coherence tomography (SS OCT) in Fuchs endothelial corneal dystrophy (FECD) eyes with a coexisting cataract. 70 eyes of 35 patients diagnosed with FECD and a coexisting cataract and 70 control eyes were included in this prospective, controlled, observational, cross-sectional study. Features characteristic of intermediately affected eyes included an increased corneal thinnest thickness (CTT) (p = 0.01), 3 and 6 mm asymmetry (p < 0.0001), higher order Fourier indices (p < 0.05 and p ≤ 0.0001, respectively), chord µ, and a posterior Ectasia Screening Index (pESI) (p < 0.01). The lack of agreement between the anterior and posterior elevation map and a significant area of negative values in the posterior map were detected. In advanced FECD eyes, our study additionally revealed decreased posterior keratometry steep (Ks), keratometry flat (Kf), keratometry average (AvgK), eccentricity (Ecc), an increased corneal apex thickness (CAT), and decreased 3 and 6 mm posterior spherical indices (p < 0.0001 for all of the above). Characteristic features of subclinical FECD, independent of the corneal thickness, can be detected by SS OCT and should be considered during the preoperative assessment of patients with a coexisting cataract.


2020 ◽  
Author(s):  
Tommy Chan ◽  
Marco Yu ◽  
Vivian Chiu ◽  
Gilda Lai ◽  
Christopher Leung ◽  
...  

Abstract Purpose To evaluate the repeatability and agreement of cornea and biometry measurements obtained with two swept-source optical coherence tomography (SSOCT) and a partial coherence interferometry-based device.METHODS This is a cross-sectional study. Forty-eight eyes of 48 patients had three consecutive measurements for ANTERION (Heidelberg Engineering, Germany), CASIAII (Tomey, Japan) and IOLMaster500 (Carl Zeiss Meditec, USA) on the same visit. Mean keratometry (Km), central cornea thickness (CCT), anterior chamber depth (ACD) and axial length (AL) were recorded. Corneal astigmatic measurements were converted into vector components – J0 and J45. Intra-device repeatability and agreements of measurements amongst the devices were evaluated using repeatability coefficients (RCs) and Bland-Altman plots, respectively. RESULTS All devices demonstrated comparable repeatability for Km (p≥0.138). ANTERION had the lowest RC for J0 amongst the devices (p≤0.039). Systematic difference was found for the Km and J0 obtained with IOLMaster500 compared to either SSOCTs (p≤0.010). The ACD and AL measured by IOLMaster500 showed a higher RC compared with either SSOCTs (p<0.002). Systematic difference was found in CCT and ACD between the two SSOCTs (p<0.001), and in AL between ANTERION and IOLMaster500 (p<0.001), with a mean difference of 1.6 µm, 0.022mm and 0.021 mm, respectively. CONCLUSIONS Both SSOCTs demonstrated smaller test-retest variability for measuring ACD and AL compared with IOLMaster500. There were significant disagreement in keratometry and AL measurements between the SSOCTs and PCI-based device; their measurements should not be considered as interchangeable but the disagreement could be refined by readjustment of intraocular lens constant in clinical practice.


2021 ◽  
Vol 8 ◽  
Author(s):  
Yujing Qian ◽  
Jingyuan Yang ◽  
Anyi Liang ◽  
Chan Zhao ◽  
Fei Gao ◽  
...  

Purpose: To investigate choroidal changes in patients with Vogt-Koyanagi-Harada disease (VKH) using widefield swept-source optical coherence tomography angiography (SS-OCTA).Methods: In this cross-sectional study, 133 eyes of 69 patients with VKH (52 eyes of 28 active VKH patients and 81 eyes of 41 inactive VKH patients) and 104 eyes of 52 age and sex matched healthy volunteers were imaged using a widefield SS-OCTA instrument. On 12 mm × 12 mm OCTA scans, mean choroidal thickness (MCT), choroidal vascularity index (CVI), choriocapillaris (CC) flow area, and mean retinal thickness (MRT) were separately calculated in the fovea (diameter of 1 mm) and in concentric rings with different radii (1–3, 3–6, 6–9, and 9–12 mm).Results: Eyes with active VKH showed significant increases in MCT, CVI, and MRT, and decreased CC flow area in all central and peripheral regions (0–1, 1–3, 3–6, 6–9, and 9–12 mm) than in the healthy eyes (p ≤ 0.01) and inactive VKH eyes (p &lt; 0.05). Inactive VKH eyes only showed marked decrease in CC flow area in all regions compared with controls (p &lt; 0.05). Flow voids were observed in 51 of 52 (98.1%) active VKH eyes and 50 of 81 (61.7%) inactive VKH eyes on 12 mm × 12 mm OCTA. The MCT of all regions was significantly correlated with age, disease duration, and disease activity, whereas CVI was associated with age and disease activity. The CC flow void was related to visual acuity in all regions (p &lt; 0.05).Conclusion: Widefield SS-OCTA enables a more comprehensive evaluation of chorioretinal changes in patients with VKH disease. Structural and vascular abnormalities are observed in both the central and peripheral choroid and are closely correlated with disease activity.


2021 ◽  
pp. 112067212110623
Author(s):  
Li-Hui Meng ◽  
Ming-Zhen Yuan ◽  
Xin-Yu Zhao ◽  
Wei-Hong Yu ◽  
You-Xin Chen

Background To investigate the features in the posterior pole of highly myopic (HM) eyes using a wide-field high-resolution swept source optical coherence tomography (SS OCT). Methods This observational cross-sectional study involved 262 eyes of 139 patients, who were diagnosed as HM and had consecutively been examined by SS OCT in the Ophthalmology Department of the Peking Union Medical College Hospital between March 2019 and December 2019. The characteristics of OCT images were documented and analyzed. Results In our study, SS OCT could demonstrate the entire layer of the choroid and detect the sclera in all eyes. The mean subfoveal retinal/choroidal/scleral thickness were 204.84 ± 119.86 μm, 92.80 ± 75.78 μm and 394.734 ± 123.09 μm, respectively. 138 eyes (52.67%) had posterior precortical vitreous pocket. Myopic foveoschisis was detected in 110 eyes (41.98%), and significantly associated with the presence of posterior staphyloma. 36 eyes (13.74%) had DSM in our study, of which 8 eyes (22.22%) showed a round dome, 16 (44.44%) were horizontal oval-shaped, 9 (25%) were vertical oval-shaped and 3 (8.34%) were oblique oval-shaped. Both SFCT and SFST were inversely and significantly associated with age and refractive errors. Macular neovascularization was significantly correlated with intrascleral vessels. Different deformation of the sclera and posterior staphyloma were vividly identified on SS OCT images. Conclusions This study provided a relatively comprehensive picture of posterior pole in HM eyes. Such good visualization of ocular fundus provided by wide-field SS OCT could be useful for the therapy option, disease condition monitoring and pathogenesis investigation.


2019 ◽  
Vol 104 (6) ◽  
pp. 795-799 ◽  
Author(s):  
Natalia Porporato ◽  
Mani Baskaran ◽  
Tin A Tun ◽  
Rehena Sultana ◽  
Marcus Tan ◽  
...  

Background/aimsAlthough being a more objective tool for assessment and follow-up of angle closure, reliability studies have reported a moderate diagnostic performance for anterior segment optical coherence tomography (OCT) technologies when comparing with gonioscopy as the reference standard. We aim to determine factors associated with diagnostic disagreement in angle closure when assessed by anterior segment swept source OCT (SS-OCT, CASIA SS-1000; Tomey, Nagoya, Japan) and gonioscopy.MethodsCross-sectional study. A total of 2027 phakic subjects aged ≥50 years, with no relevant previous ophthalmic history, were consecutively recruited from a community polyclinic in Singapore. Gonioscopy and SS-OCT (128 radial scans) for the entire circumference of the angle were performed for each subject. A two-quadrant closed gonioscopic definition was used. On SS-OCT images, angle closure was defined as iridotrabecular contact (ITC) to the extent of ≥35%, ≥50% and ≥75% of the circumferential angle. Diagnostic disagreements between both methods, that is, false positives or overcalls and false negatives or undercalls were defined, respectively, as gonioscopic open/closed angles inversely assessed as closed/open by SS-OCT.ResultsTwo hundred and seventy-two (14.7%) resulted in overcall results (false positives) when ≥50% of the angle circumference was closed using SS-OCT. These eyes had significantly wider (anterior chamber width, 11.7 vs 11.6 mm, p<0.001) and deeper (anterior chamber depth (ACD), 2.4 vs 2.2 mm, p<0.001) anterior chambers than eyes assessed by both methods as closed (true positives). Deeper ACD (OR 9.31) and lower lens vault (LV) (OR 0.04) were significantly associated with a false positive diagnosis in the multivariate analysis. Most of these cases had short (52.6%) or irregular (39%) ITC in SS-OCT images.ConclusionsWe found that anterior chamber dimensions, determined by ACD and LV, were factors significantly associated with diagnostic disagreement between anterior segment SS-OCT and gonioscopy in angle closure assessment.


2017 ◽  
Vol 2017 ◽  
pp. 1-10 ◽  
Author(s):  
Shiqi Yang ◽  
Minwen Zhou ◽  
Bing Lu ◽  
Pengfei Zhang ◽  
Jingke Zhao ◽  
...  

Purpose. To quantify macular vascular density using optical coherence tomography angiography (OCTA) and to investigate its relationship with retinal thickness in myopic eyes of young adults.Methods. In this cross-sectional study, 268 myopic eyes without pathological changes were recruited and divided into three groups: mild myopia (n=81), moderate myopia (n=117), and high myopia (n=70). Macular vascular density was quantified by OCTA and compared among three groups. Average retinal thickness, central subfield thickness, and macular ganglion cell complex (mGCC) thickness were also evaluated and compared. Correlations among these variables were analyzed.Results. There was no statistical difference in superficial (62.3 ± 5.7% versus 62.7 ± 5.9% versus 63.8 ± 5.5%) and deep macular vascular densities (58.3 ± 9.6% versus 59.2 ± 9.3% versus 60.9 ± 7.9%) among mild-myopia, moderate-myopia, and high-myopia groups (bothP>0.05). Superficial and deep macular vascular densities both had correlations with mean arterial pressure. Furthermore, superficial macular vascular density was significantly correlated with mGCC thickness.Conclusions. Varying degrees of myopia did not affect macular vascular density in young healthy adults. In addition, superficial macular vascular density, as an independent factor, was positively correlated with mGCC thickness.


2017 ◽  
Vol 1 (1) ◽  
pp. 41-44
Author(s):  
Miguel Ruão ◽  
María Andreu-Fenoll ◽  
Rosa Dolz-Marco ◽  
Roberto Gallego-Pinazo

Purpose: To evaluate the prevalence of different optical coherence tomography (OCT) findings in European patients with high myopia. Methods: Cross-sectional study conducted in the Macula Unit of the University and Polytechnic Hospital La Fe (Valencia, Spain). A total of 134 myopic eyes of 69 patients (16 males and 53 females) were included. All patients underwent a spectral domain OCT examination at least once. The presence of tractional and atrophic myopic maculopathy and choroidal neovascularization (CNV) was evaluated through OCT scans. Results: The prevalence of tractional myopic maculopathy was found in 53.7% of the eyes. Within this group, 9.7% had foveal retinoschisis, 23.9% extrafoveal retinoschisis, 31.3% internal limiting membrane rigidity, 24.6% epiretinal membrane, and none had vitreomacular traction. The most prevalent OCT finding was chorioretinal atrophy, present in 79.1% of the eyes. Choroidal neovascularization was present in 61.9% of the eyes. There was a trend toward higher prevalence of CNV in eyes with patchy atrophy with foveal involvement compared to those without foveal involvement (81.8% vs 65.5%; P = .103). Conclusion: The prevalence of CNV was quite high, especially in patients with patchy atrophy with foveal involvement.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Tommy C. Y. Chan ◽  
Marco C. Y. Yu ◽  
Vivian Chiu ◽  
Gilda Lai ◽  
Christopher K. S. Leung ◽  
...  

AbstractTo evaluate the repeatability and agreement of corneal and biometry measurements obtained with two swept-source optical coherence tomography (SSOCT) and a partial coherence interferometry-based device. This is a cross-sectional study. Forty-eight eyes of 48 patients had three consecutive measurements for ANTERION (Heidelberg Engineering, Germany), CASIAII (Tomey, Japan) and IOLMaster500 (Carl Zeiss Meditec, USA) on the same visit. Mean keratometry (Km), central corneal thickness (CCT), anterior chamber depth (ACD) and axial length (AL) were recorded. Corneal astigmatic measurements were converted into vector components—J0 and J45. Intra-device repeatability and agreements of measurements amongst the devices were evaluated using repeatability coefficients (RCs) and Bland–Altman plots, respectively. All devices demonstrated comparable repeatability for Km (p ≥ 0.138). ANTERION had the lowest RC for J0 amongst the devices (p ≤ 0.039). Systematic difference was found for the Km and J0 obtained with IOLMaster500 compared to either SSOCTs (p ≤ 0.010). The ACD and AL measured by IOLMaster500 showed a higher RC compared with either SSOCTs (p < 0.002). Systematic difference was found in CCT and ACD between the two SSOCTs (p < 0.001), and in AL between ANTERION and IOLMaster500 (p < 0.001), with a mean difference of 1.6 µm, 0.022 mm and 0.021 mm, respectively. Both SSOCTs demonstrated smaller test–retest variability for measuring ACD and AL compared with IOLMaster500. There were significant disagreement in keratometry and AL measurements between the SSOCTs and PCI-based device; their measurements should not be considered as interchangeable.


2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Dawei Fang ◽  
Qingjian Li ◽  
Ke Yan ◽  
Sennan Xu ◽  
Jing Jiang ◽  
...  

Purpose. To evaluate the relationships between C-reactive protein (CRP) and retinal and choroidal thickness by swept-source optical coherence tomography (SS-OCT). Methods. The participants included in the prospective cross-sectional study underwent a comprehensive ophthalmic examination. Based on the CRP values, the subjects were divided into the CRP (+) group ( CRP ≥ 8.2  mg/L) and the CRP (−) group ( CRP < 8.2  mg/L). The retinal and choroidal thickness was compared between the two groups. Results. This study enrolled 43 right eyes of 43 subjects from the CRP (+) group and 86 right eyes of 86 gender- and age-match subjects from the CRP (−) group. The choroidal thickness in the CRP (+) group was thinner than that in the CRP (−) group except for the outer nasal sector of the Early Treatment Diabetic Retinopathy Study (ETDRS) grid. However, the retinal thickness only in the inner temporal sector showed a significant difference. According to Pearson’s correlation analysis, the CRP was significantly negatively correlated with the choroidal thickness in all sectors and the retinal thickness only in the inner temporal and outer nasal sectors of the ETDRS grid. Conclusion. CRP levels are associated with retinal and choroidal thickness. The data related to the retinal and choroidal thickness changes may help understand the pathogenesis of specific ocular abnormalities in patients with systemic inflammation.


Sign in / Sign up

Export Citation Format

Share Document