scholarly journals Characterization of a population of small macrophages in induced sputum of patients with chronic obstructive pulmonary disease and healthy volunteers

2004 ◽  
Vol 138 (3) ◽  
pp. 507-516 ◽  
Author(s):  
M. FRANKENBERGER ◽  
M. MENZEL ◽  
R. BETZ ◽  
G. KAssNER ◽  
N. WEBER ◽  
...  
2021 ◽  
Vol 42 (1) ◽  
pp. 30-35 ◽  
Author(s):  
Donald P. Tashkin ◽  
Arkady Koltun ◽  
Róisín Wallace

Background: A generic combination of fluticasone propionate and salmeterol xinafoate inhalation powder in a premetered, multidose, nonreusable inhaler was recently approved. Objective: To assess the performance of the generic device. Methods: Findings from three studies with regard to device usability, function, and robustness were reviewed. Results: In a study to assess device function in patients and healthy volunteers, the generic device was successfully used by patients with asthma and chronic obstructive pulmonary disease who were either dry powder inhaler users or dry powder inhaler‐naive, even though they were not trained beyond being provided the instructions for use. In a study to measure inhaled flow rates generated by patients and healthy volunteers, the generic device consistently simulated the delivery of a full dose of drug, even to patients with severe respiratory disease and reduced inspiratory flow rates. Although the generic device had a slightly higher airflow resistance, this study demonstrated that this difference did not result in any clinically meaningful differences in terms of drug delivery. Pressure drop, a key parameter that drives the fluidization and aerosolization of the powder dose, was found to be comparable between the devices. In an open-label study, the generic device met all U.S. Food and Drug Administration specifications for device robustness after 21.5 days of twice-daily dosing via oral inhalation among 111 participants with asthma or chronic obstructive pulmonary disease. All inhalers tested demonstrated conformity with a pharmacopeia with respect to key quality parameters (assay, delivered dose uniformity, aerodynamic size distribution). There was no evidence of chemical degradation of the active ingredients, nor of microbial or water ingress into the powder, as a result of inhaler use.


2019 ◽  
Vol 9 (24) ◽  
Author(s):  
Lalita Fernandes ◽  
Shraddha Rane ◽  
Suresh Mandrekar ◽  
Anthony Menezes Mesquita

Background. Chronic obstructive pulmonary disease (COPD) is an inflammatory disease with predominant involvement of neutrophils, macrophages and CD8+ lymphocytes. Eosinophilic airway inflammations are reported in stable state and during acute exacerbations of tobacco smoke-associated COPD (TS-COPD). Women exposed to biomass fuel smoke are known to have eosinophils in sputum. However, little is known about the sputum cellular inflammatory profile in biomass fuel smoke-associated COPD (BMS-COPD). We therefore aimed to compare the sputum cellular inflammatory profile in tobacco smoke- and biomass smoke-associated COPD. Methods. The study was conducted in a tertiary care hospital in Goa, India. A total of 113 patients with stable COPD reporting to the outpatient pulmonary clinic were recruited. All participants were ≥ 40 years of age. Sputum induction studies were performed by the method of Pizzichini et al. after baseline subject characterization. Significant eosinophilia was defined as induced sputum eosinophils ≥ 3%. Results. There were 85 TS-COPD and 28 BMS-COPD patients. The mean age [standard deviation (SD)] was 64.7 (7.8) and 63.0 years (8.3), p = 0.32 in TS and BMS-COPD, respectively. Eighteen subjects (21.1%) were female smokers. The smoking pack-year median [interquartile range (IQR)] was 36 (20, 58) and hour-years of biomass smoke exposure mean (SD) was 192.4 (61). The TS-COPD and BMS-COPD cases showed a post-bronchodilator forced expiratory volume in one second (FEV1%) mean (SD) of 57.9 (17.1), and 62.6 (19.4), p= 0.22, respectively. Both groups had similar symptoms and severity of disease. Induced sputum total cell count per gram of sputum × 106 mean (SD) was 3.05 (1.53) for TS-COPD, and 2.55(1.37) for BMS-COPD p=0.12. The neutrophils % mean (SD) was 86.4 (16.5) and 87.9 (10.2), p = 0.64; eosinophils % median (IQR) was 2.5 (1, 10) and 8 (2, 12.8), p = 0.07; lymphocytes % median (IQR) was 0 (0, 0.75) and 0 (0, 1) p = 0.13; macrophages % median (IQR) was 2.5 (0.75, 5.7) and 1 (0, 4.7) p = 0.13; and significant eosinophilia (eosinophils ≥3%) was 42 (49.4%) and 20 (71%), p=0.04, for TS-COPD and BMS-COPD, respectively. Conclusions. For similar severity of disease and clinical symptoms, significant eosinophilic inflammation was observed in stable BMS-COPD, while both groups had similar neutrophilic inflammation. Participant Consent. Obtained. Ethics Approval. The study was approved by the Institutional Ethics Committee of the Goa Medical College, Goa, India. Competing Interests. The authors declare no competing financial interests.


2015 ◽  
Vol 79 (5) ◽  
pp. 767-776 ◽  
Author(s):  
Vandana Gupta ◽  
Antonia Banyard ◽  
Aoibheann Mullan ◽  
Srividya Sriskantharajah ◽  
Thomas Southworth ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document