Inappropriate Shock Delivery by Implantable Defibrillators with Dual Chamber Pacing During Nonsustained Ventricular Tachycardia in Patients with Heart Block

2000 ◽  
Vol 23 (6) ◽  
pp. 1054-1056 ◽  
Author(s):  
JASBIR SRA ◽  
MASOOD AKHTAR
Circulation ◽  
2021 ◽  
Vol 144 (Suppl_2) ◽  
Author(s):  
James M Gray ◽  
Tia T Raymond ◽  
Dianne L Atkins ◽  
Ken Tegtmeyer ◽  
Dana E Niles ◽  
...  

Introduction: Shockable rhythms (ventricular fibrillation [VF] and ventricular tachycardia [VT]) occur in <25% of pediatric in-hospital cardiac arrest (IHCA) events, yet the prevalence of inappropriate defibrillation attempts for non-VF/VT rhythms is unknown. We aim to describe the prevalence of inappropriate shocks across a large, multi-national pediatric cardiac arrest network. Methods: We included children <18y reported to the pedi atric RES uscitation- Q uality (pediRES-Q) network from 2015-2019 with complete defibrillator files who received defibrillation attempts during IHCA (ZOLL R-Series, MA). Two pediatric cardiologists independently classified rhythms immediately prior to shock as: 1) appropriate (VF or wide complex ≥ 150/min), 2) indeterminate (narrow complex ≥150/min or wide complex 100-149/min), or 3) inappropriate (asystole, sinus, narrow complex <150/min, or wide complex <100/min). Rhythms that were undecipherable due to artifact were excluded from analysis (n=22). Disagreements were resolved by arbitration and consensus. Results: Of 896 IHCA events, 124 (14%) had defibrillation attempts. A total of 303 shocks were delivered: 87 (29%) in age <1y, 84 (28%) in 1-8y, and 132 (44%) in 9-17y. Of shocks delivered, 206 (68%) were appropriate, 12 (4%) indeterminate, and 85 (28%) inappropriate. There was no difference in inappropriate shock delivery by age category: <1y (24/87, 28%), 1-8y (26/84, 31%), 9-17y (35/132, 27%) ( p =0.4). Conclusions: Across a multi-national pediatric cardiac arrest network, a large proportion (28%) of defibrillation attempts were inappropriate, suggesting significant opportunity for improvement in rhythm identification in pediatric cardiac arrest. There was no difference in inappropriate shock delivery across age groups. Figure 1. Representation of rhythm classification and appropriateness of defibrillation attempts with exemplar rhythms.


1986 ◽  
pp. 472-474
Author(s):  
J. Ernesto Molina ◽  
Naip Tuna ◽  
Ann Dunnigan ◽  
D. Woodrow Benson ◽  
David G. Benditt

2021 ◽  
Vol 10 (4) ◽  
pp. 235-240
Author(s):  
Rahul K. Mukherjee ◽  
Manav Sohal ◽  
Nesan Shanmugam ◽  
Simon Pearse ◽  
Fadi Jouhra

The presence of supraventricular tachycardia is the leading cause of inappropriate shock in ICD recipients, and it can be a significant cause of morbidity, psychological distress and worsened clinical outcome. Modern pacing and ICD systems offer a number of discriminators that are integrated into algorithms to differentiate sustained ventricular tachycardia from supraventricular tachycardia. These algorithms can be adapted and optimised for each individual patient to ensure that only those arrhythmias that need treatment through the use of an ICD, are actually treated. This review summarises the single- and dual-chamber discriminators that can be used in the detection and classification of tachyarrhythmias.