scholarly journals Risk of Further Decline in Renal Function After the Use of Oral Sodium Phosphate or Polyethylene Glycol in Patients With a Preexisting Glomerular Filtration Rate Below 60 ml/min

2008 ◽  
Vol 103 (11) ◽  
pp. 2707-2716 ◽  
Author(s):  
Stefan Russmann ◽  
Lois Lamerato ◽  
Stephen P. Motsko ◽  
John C. Pezzullo ◽  
Mark D. Faber ◽  
...  
2007 ◽  
Vol 102 (12) ◽  
pp. 2655-2663 ◽  
Author(s):  
Stefan Russmann ◽  
Lois Lamerato ◽  
Aditya Marfatia ◽  
Stephen P. Motsko ◽  
John C. Pezzullo ◽  
...  

2007 ◽  
Vol 21 (4) ◽  
pp. 227-231 ◽  
Author(s):  
Ramy Abaskharoun ◽  
William Depew ◽  
Stephen Vanner

Changes in renal function were compared in patients receiving oral sodium phosphate (NaP) for colon cleansing and those receiving large-volume polyethylene glycol (PEG) solution to determine whether oral NaP resulted in frequent renal damage that had gone clinically undetected. From 1995 to 2004, a cohort of consecutive patients who had serum creatinine (Cr) drawn immediately before colonoscopy and again after subsequent procedures three months to nine years later (almost 80% of patients between the first and fifth year) were identified. Chronic renal failure (CRF) was defined as an abnormal Cr at repeat measurement or an abnormal Cr clearance as estimated by the Cockroft-Gault equation at the time of repeat Cr measurement. Medications and medical comorbid conditions were recorded. Seven hundred sixty-seven patients (51% female and 49% male; 81% oral NaP and 19% PEG) with normal baseline Cr levels were identified through the endoscopy unit database at the Hotel Dieu Hospital, Queen’s University (Kingston, Ontario). Of these, 55 (7%) developed CRF. Forty-two (6.8%) patients receiving oral NaP developed renal failure compared with 13 patients (8.7%) receiving PEG (Fisher’s exact test; P=0.382), but the magnitude of CRF was small in each group (Cr level lower than 160 μmol/L). Using logistic regression analysis with the choice of preparation, medications and medical comorbid conditions as independent variables, only age and blood pressure were predictive of the development of renal failure (P=0.014 and P=0.001, respectively). Baseline Cr clearance was similiar in both the NaP and PEG groups and the absolute difference after colonoscopy did not differ. The present study concluded that the ingestion of oral NaP for colon cleansing before colonoscopy did not result in frequent renal damage that went clinically undetected.


1971 ◽  
Vol 10 (01) ◽  
pp. 16-24
Author(s):  
J. Fog Pedersen ◽  
M. Fog Pedersen ◽  
Paul Madsen

SummaryAn accurate catheter-free technique for clinical determination simultaneouslyof glomerular filtration rate and effective renal plasma flow by means of radioisotopes has been developed. The renal function is estimated by the amount of radioisotopes necessary to maintain a constant concentration in the patient’s blood. The infusion pumps are steered by a feedback system, the pumps being automatically turned on when the radiation measured over the patient’s head falls below a certain preset level and turned off when this level is again readied. 131I-iodopyracet was used for the estimation of effective renal plasma flow and125I-iothalamate estimation of the glomerular filtration rate. These clearances were compared to the conventional bladder clearances and good correlation was found between these two clearance methods (correlation coefficients 0.97 and.90 respectively). The advantages and disadvantages of this new clearance technique are discussed.


2014 ◽  
pp. 73-77
Author(s):  
Van Chuong Nguyen ◽  
Thi Kim Anh Nguyen

Background: A Research glomerular filtration rate (GFR) of 61 patients with type 2 diabetes mellitus with renal scanning 99mTc-DTPA glomerular filtration rate at the hospital 175. Objective: (1) To study characteristics of imaging of renal function. (2) Understanding the relationship between GFR with blood sugar, HbA1c, blood pressure and albuminuria in patients with type 2 diabetes. Methods: Descriptive, prospective, cross-sectional study. Clinical examination, Clinical tests and 99mTc-DTPA GFR gamma - camera renography for patients. Result: GFR of the study group was 75,4 ± 22,3 ml/phut/1,73m2, the left kidney was 35,0 ± 13,0 is lower than the right kidney and 39,8 ± 11,9; p <0,01. There is no correlation between GFR with blood glucose and HbA1c, the risk of reduced GFR in hypertensive group associated is OR = 6,5 with p<0,01; albuminuria (+) is OR = 4,2 with p <0,01; and disease duration > 10 years is OR = 3,5 with p <0.01. Conclusion: GFR of the left kidneys is lower than the right kidney; correlation decreased GFR associated with hypertension, albuminuria and disease duration. Keywords: GFR, diabetes, albuminuria


2014 ◽  
Vol 39 (2) ◽  
pp. 74-79
Author(s):  
F Jahan ◽  
MNU Chowdhury ◽  
T Mahbub ◽  
SM Arafat ◽  
S Jahan ◽  
...  

To ensure that potential kidney donors in Bangladesh have no renal impairment, it is extremely important to have accurate methods for evaluating the glomerular filtration rate (GFR). We evaluated the performance of serum creatinine based GFR in healthy adult potential kidney donors in Bangladesh to compare GFR determined by DTPA with that determined by various prediction equations. In this study GFR in 61 healthy adult potential kidney donors were measured with 99mTc-diethylenetriamine penta-acetic acid (DTPA) renogram. We also estimated GFR using a four variable equation modification of diet in renal disease (MDRD), Cockcroft-Gault creatinine clearance (CG CrCl), Cockcroft-Gault glomerular filtration rate (CG-GFR). The mean age of study population was 34.31±9.46 years and out of them 65.6% was male. In this study mean mGFR was 85.4±14.8. Correlation of estimated GFR calculated by CG-CrCl, CG-GFR and MDRD were done with measured GFR DTPA using quartile. Kappa values were also estimated which was found to be 0.104 for (p=0.151), 0.336 for (p=0.001) and 0.125 for (p=0.091) respectively. This indicates there is no association between estimated GFR calculated by CG-CrCl, CG-GFR, MDRD with measured GFR DTPA. These results show poor performance of these equations in evaluation of renal function among healthy population and also raise question regarding validity of these equations for assessment of renal function in chronic kidney disease in our population. DOI: http://dx.doi.org/10.3329/bmrcb.v39i2.19646 Bangladesh Med Res Counc Bull 2013; 39: 74-79


Folia Medica ◽  
2012 ◽  
Vol 54 (4) ◽  
pp. 5-13 ◽  
Author(s):  
Bilyana H. Teneva

Abstract In liver cirrhosis patients awaiting liver transplantation, it is prognostically equally important to assess the renal function before and after transplantation. This is evidenced by the inclusion of serum creatinine in the Model for End-Stage Liver Disease (MELD) score. Most of the causes of renal failure in liver cirrhosis are functional, the acute kidney damage including prerenal azotemia, acute tubular necrosis and hepatorenal syndrome. A major index of the renal function, the glomerular filtration rate (GFR) is determined in a specific way in patients with liver cirrhosis. Clinically, serum creatinine is considered the best indicator of kidney function, although it is rather unreliable when it comes to early assessment of renal dysfunction. Most of the patients with liver cirrhosis have several concomitant conditions, which are the reason for the false low creatinine levels, even in the presence of moderate to severe kidney damage. This also holds for the creatinine clearance and creatinine-based estimation equations for assessment of the glomerular filtration rate (the Cockroft-Gault and MDRD formulas), which overestimate the real glomerular filtration. Clearance of exogenous markers is considered a gold standard, but the methods for their determination are rather costly and hard to apply. Alternative serum markers (e.g., cystatin C) have been used, but they should be better studied in cases of liver cirrhosis assessment.


Sign in / Sign up

Export Citation Format

Share Document