scholarly journals Incidence of ablation‐induced esophageal injury associated with high‐power short duration temperature‐controlled pulmonary vein isolation using a specialized open‐irrigated ablation catheter: A retrospective single‐center study

Author(s):  
Robert Piringer ◽  
Thomas Deneke ◽  
Borek Foldyna ◽  
Kai Sonne ◽  
Karin Nentwich ◽  
...  
EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
CH Heeger ◽  
MS Sano ◽  
RMS Meyer-Saraei ◽  
CE Eitel ◽  
HL Phan ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Background Catheter ablation for atrial fibrillation (AF) treatment provides effective and durable PVI associated with encouraging clinical outcome. The novel QDot ablation catheter with Qmode + ablation mode (90W/4sec, Figure 1) offers the ability to possibly improve safety and decrease ablation procedure times. Aims We aim to evaluate safety and efficacy of the very high-power short-duration (vHP-SD) temperature-controlled radiofrequency (RF) ablation Qmode + mode for pulmonary vein isolation (PVI) utilizing the novel QDot micro ablation catheter. The data was compared to conventional power-controlled ablation index (AI) guided PVI. Methods Twenty-five consecutive patients with paroxysmal or persistent AF were prospectively enrolled, underwent vHP-SD based PVI (vHP-SD group) and were compared to 25 consecutive patients treated with conventional CF-sensing catheters (control). Results All PVs were successfully isolated utilizing Qmode +. The total median RF ablation time was vHP-SD: 334 (282, 369) sec. vs control: 1567 (1250, 1756) sec. (p < 0.0001), the median procedure time was vHP-SD: 56 (48-62) vs. control: 104 (92-122) min (p < 0.0001). No differences in periprocedural complications were observed. Conclusions The novel Qmode + provides safe and effective PVI with impressive short RF time and short procedures times. Procedure time and RF time were substantial lower in the vHP-SD group. Abstract Figure 1


2019 ◽  
Vol 5 (7) ◽  
pp. 778-786 ◽  
Author(s):  
Vivek Y. Reddy ◽  
Massimo Grimaldi ◽  
Tom De Potter ◽  
Johan M. Vijgen ◽  
Alan Bulava ◽  
...  

Author(s):  
Hagai D. Yavin ◽  
Zachary P. Bubar ◽  
Koji Higuchi ◽  
Jakub Sroubek ◽  
Mohamed Kanj ◽  
...  

Background: High-power short-duration (HP-SD) radiofrequency ablation (RFA) has been proposed as a method for producing rapid and effective lesions for pulmonary vein isolation. The underlying hypothesis assumes an increased resistive heating phase and decreased conductive heating phase, potentially reducing the risk for esophageal thermal injury. The objective of this study was to compare the esophageal temperature dynamic profile between HP-SD and moderate-power moderate-duration (MP-MD) RFA ablation strategies. Methods: In patients undergoing pulmonary vein isolation, RFA juxtaposed to the esophagus was delivered in an alternate sequence of HP-SD (50 W, 8–10 s) and MP-MD (25 W, 15–20 s) between adjacent applications (distance, ≤4 mm). Esophageal temperature was recorded using a multisensor probe (CIRCA S-CATH). Temperature data included magnitude of temperature rise, maximal temperature, time to maximal temperature, and time return to baseline. In swine, a similar experimental design compared the effect of HP-SD and MP-MD on patterns of esophageal injury. Results: In 20 patients (68.9±5.8 years old; 60% persistent atrial fibrillation), 55 paired HP-SD and MP-MD applications were analyzed. The esophageal temperature dynamic profile was similar between HP-SD and MP-MD ablation strategies. Specifically, the magnitude of temperature rise (2.1 °C [1.4–3] versus 2.0 °C [1.5–3]; P =0.22), maximal temperature (38.4 °C [37.8–39.3] versus 38.5 °C [37.9–39.4]; P =0.17), time to maximal temperature (24.9±7.5 versus 26.3±6.8 s; P =0.1), and time of temperature to return to baseline (110±23.2 versus 111±25.1 s; P =0.86) were similar between HP-SD and MP-MD ablation strategies. In 6 swine, esophageal injury was qualitatively similar between HP-SD and MP-MD strategies. Conclusions: Esophageal temperature dynamics are similar between HP-SD and MP-MD RFA strategies and result in comparable esophageal tissue injury. Therefore, when using a HP-SD RFA strategy, the shorter application duration should not prompt shorter intervals between applications.


Author(s):  
Takashi Kaneshiro ◽  
Masashi Kamioka ◽  
Naoko Hijioka ◽  
Shinya Yamada ◽  
Tetsuro Yokokawa ◽  
...  

Background: The mechanism of esophageal thermal injury (ETI; esophageal mucosal injury and periesophageal nerve injury leading to gastric hypomotility) remains unknown when using a high-power short-duration (HP-SD) setting. This study sought to evaluate the characteristics of esophageal injuries in atrial fibrillation ablation using a HP-SD setting. Methods: After exclusion of 5 patients with their esophagus at the right portion of left atrium and 21 patients with additional ablations such as box isolation and low voltage area ablation in left atrium posterior wall, 271 consecutive patients (62±10 years, 56 women) who underwent pulmonary vein isolation by radiofrequency catheter ablation were analyzed. In the 101 patients, a HP-SD setting at 45 to 50 W with an Ablation Index module was used (HP-SD group). In the remaining 170 patients before introduction of the HP-SD setting, a conventional power setting of 20 to 30 W with contact force monitoring was used (conventional group). We performed esophagogastroduodenoscopy after pulmonary vein isolation in all patients and investigated the incidence and characteristics of ETI. Results: Although the incidence of ETI was significantly higher in the HP-SD group compared with the conventional group (37% versus 22%, P =0.011), the prevalence of esophageal lesions did not differ between the groups (7% versus 8%). Multivariate logistic regression analysis revealed that the use of the HP-SD setting (odds ratio, 6.09, P <0.001), and the parameters that suggest anatomic proximity surrounding the esophagus, were independent predictors of ETI. However, the majority of ETI in the HP-SD group was gastric hypomotility, and the thermal injury was limited to the shallow layer of the periesophageal wall using the HP-SD setting. Conclusions: Although the use of the HP-SD setting was a strong predictor of ETI, it could avoid deeper thermal injuries that reach the esophageal mucosal layer.


Author(s):  
Marc Kottmaier ◽  
Leonie Förschner ◽  
Nada Harfoush ◽  
Felix Bourier ◽  
Sarah Mayr ◽  
...  

Background High power short duration (HPSD) radiofrequency-ablation (RFA) is highly efficient and safe while reducing procedure and RF time in pulmonary vein isolation (PVI). The QDot-catheter is a novel contact-force ablation catheter that allows automated flow and power adjustments depending on the local tissue temperature to maintain a target temperature during 90watts/4seconds lesions. We analysed intraprocedural data and periprocedural safety using the QDot-catheter in patients undergoing PVI for paroxysmal atrial fibrillation (PAF). Methods We included n=48 patients undergoing PVI with the QDot-catheter with a temperature controlled HPSD ablation mode with 90watts/4seconds (TC-HPSD). If focal reconnection occurred besides repeat ablation the ablation mode was changed to 50watts/15seconds (QMode). N=23 patients underwent cerebral MRI to detect silent cerebral lesions. Results Mean RF-time was 8.1+/-2.8min, procedure-duration was 84.5+/-30min. The overall maximal measured catheter-tip temperature was 52.0°C +/- 4.6°C, mean overall applied current was 871mA +/-44mA and over all applied energy was 316J +/-47J. The mean local impedance-drop was 12.1 +/- 2.4 Ohms. During Adenosine challenge n=14 (29%) patients showed dormant conduction. A total of n=24 steam pops were detected in n=18 patients (39.1%), while no pericardial tamponade occurred. No periprocedural thromboembolic complications occurred, while n=4 patients (17.4%) showed silent cerebral lesion. Conclusion TC-HPSD ablation with 90watts/4seconds using the QDot-catheter led to a reduction of procedure and RF time, while no major complications occurred. Despite optimized temperature control and power adjustment steam pops occurred in a rather high number of patients, while none of them lead to tamponade or to clinical or neurological deficits.


Sign in / Sign up

Export Citation Format

Share Document