Correlation between nuclear magnetic resonance and traditional method to evaluate the lipid oxidation of emulsified chicken meat products with fat replacement by green banana biomass

Author(s):  
Bruna E. Auriema ◽  
Juarez Vicente ◽  
Mario G. Carvalho ◽  
Rosane N. Castro ◽  
Rosa H. Luchese ◽  
...  
LWT ◽  
2017 ◽  
Vol 86 ◽  
pp. 20-24 ◽  
Author(s):  
Giulia Tasoniero ◽  
Hanne Christine Bertram ◽  
Jette Feveile Young ◽  
Antonella Dalle Zotte ◽  
Eero Puolanne

2003 ◽  
Vol 86 (6) ◽  
pp. 1193-1202 ◽  
Author(s):  
Jimmy T Keeton ◽  
Brian S Hafley ◽  
Sarah M Eddy ◽  
Cindy R Moser ◽  
Bobbie J McManus ◽  
...  

Abstract A peer-verified method is presented for the determination of percent moisture and fat in meat products by microwave drying and nuclear magnetic resonance (NMR) analysis. The method involves determining the moisture content of meat samples by microwave drying and using the dried sample to determine the fat content by NMR analysis. Both the submitting and peer laboratories analyzed 5 meat products by using the CEM SMART system (moisture) and the SMART Trac (fat). The samples, which represented a range of products that meat processors deal with daily in plant operations, included the following: 1) fresh ground beef, high-fat; 2) deboned chicken with skin; 3) fresh pork, low-fat; 4) all-beef hot dogs; and 5) National Institute of Standards and Technology Standard Reference Material. The results were compared with moisture and fat values derived from AOAC-approved methods, 950.46 (Forced Air Oven Drying) and 960.39 (Soxhlet Ether Extraction).


Author(s):  
M.J. Hennessy ◽  
E. Kwok

Much progress in nuclear magnetic resonance microscope has been made in the last few years as a result of improved instrumentation and techniques being made available through basic research in magnetic resonance imaging (MRI) technologies for medicine. Nuclear magnetic resonance (NMR) was first observed in the hydrogen nucleus in water by Bloch, Purcell and Pound over 40 years ago. Today, in medicine, virtually all commercial MRI scans are made of water bound in tissue. This is also true for NMR microscopy, which has focussed mainly on biological applications. The reason water is the favored molecule for NMR is because water is,the most abundant molecule in biology. It is also the most NMR sensitive having the largest nuclear magnetic moment and having reasonable room temperature relaxation times (from 10 ms to 3 sec). The contrast seen in magnetic resonance images is due mostly to distribution of water relaxation times in sample which are extremely sensitive to the local environment.


Author(s):  
Paul C. Lauterbur

Nuclear magnetic resonance imaging can reach microscopic resolution, as was noted many years ago, but the first serious attempt to explore the limits of the possibilities was made by Hedges. Resolution is ultimately limited under most circumstances by the signal-to-noise ratio, which is greater for small radio receiver coils, high magnetic fields and long observation times. The strongest signals in biological applications are obtained from water protons; for the usual magnetic fields used in NMR experiments (2-14 tesla), receiver coils of one to several millimeters in diameter, and observation times of a number of minutes, the volume resolution will be limited to a few hundred or thousand cubic micrometers. The proportions of voxels may be freely chosen within wide limits by varying the details of the imaging procedure. For isotropic resolution, therefore, objects of the order of (10μm) may be distinguished.Because the spatial coordinates are encoded by magnetic field gradients, the NMR resonance frequency differences, which determine the potential spatial resolution, may be made very large. As noted above, however, the corresponding volumes may become too small to give useful signal-to-noise ratios. In the presence of magnetic field gradients there will also be a loss of signal strength and resolution because molecular diffusion causes the coherence of the NMR signal to decay more rapidly than it otherwise would. This phenomenon is especially important in microscopic imaging.


Sign in / Sign up

Export Citation Format

Share Document