A comparison of contact force and remote magnetic navigation on lesion formation for the ablation of atrial fibrillation

2018 ◽  
Vol 41 (5) ◽  
pp. 450-458 ◽  
Author(s):  
Stefano Grossi ◽  
Francesco Grassi ◽  
Lorenzo Galleani ◽  
Francesca Bianchi ◽  
Maria Rosa Conte

2020 ◽  
Vol 164 (4) ◽  
pp. 387-393
Author(s):  
Jiri Jez ◽  
Tomasz Jadczyk ◽  
Frantisek Lehar ◽  
Martin Pesl ◽  
Tomas Kulik ◽  
...  


2018 ◽  
Vol 2018 ◽  
pp. 1-8
Author(s):  
Xiao-yu Liu ◽  
Hai-feng Shi ◽  
Jie Zheng ◽  
Ku-lin Li ◽  
Xiao-xi Zhao ◽  
...  

Objective. The objective of this study was to investigate the impact of left atrial (LA) size for the ablation of atrial fibrillation (AF) using remote magnetic navigation (RMN). Methods. A total of 165 patients with AF who underwent catheter ablation using RMN were included. The patients were divided into two groups based on LA diameter. Eighty-three patients had small LA (diameter <40 mm; Group A), and 82 patients had a large LA (diameter ≥40 mm; Group B). Results. During mapping and ablation, X-ray time (37.0 (99.0) s vs. 12 (30.1) s, P<0.001) and X-ray dose (1.4 (2.7) gy·cm2 vs. 0.7 (2.1) gy·cm2, P=0.013) were significantly higher in Group A. No serious complications occurred in any of the patients. There was no statistical difference in the rate of first anatomical attempt of pulmonary vein isolation between the two groups (71.1% vs. 57.3%, P=0.065). However, compared with Group B, the rate of sinus rhythm was higher (77.1% vs. 58.5%, P<0.001) during the follow-up period. More patients in Group A required a sheath adjustment (47/83 vs. 21/82, P<0.001), presumably due to less magnets positioned outside of the sheath. In vitro experiments with the RMN catheter demonstrated that only one magnet exposed created the sheath affects which influenced the flexibility of the catheter. Conclusions. AF ablation using RMN is safe and effective in both small and large LA patients. Patients with small LA may pose a greater difficulty when using RMN which may be attributed to the fewer magnets beyond the sheath. As a result, the exposure of radiation was increased. This study found that having at least two magnets of the catheter positioned outside of the sheath can ensure an appropriate flexibility of the catheter.



2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Di Cori ◽  
L Segreti ◽  
G Zucchelli ◽  
S Viani ◽  
F Tarasco ◽  
...  

Abstract Background Contact force catheter ablation is the gold standard for treatment of atrial fibrillation (AF). Local tissue impedance (LI) evaluation has been recently studied to evaluate lesion formation during radiofrequency ablation. Purpose Aim of the study was to assess the outcomes of an irrigated catether with LI alghorithm compared to contact force (CF)-sensing catheters in the treatment of symptomatic AF. Methods A prospective, single-center, nonrandomized study was conducted, to compare outcomes between CF-AF ablation (Group 1) and LI-AF ablation (Group 2). For Group 1 ablation was performed using the Carto 3© System with the SmartTouch SF catheter and, as ablation target, an ablation index value of 500 anterior and 400 posterior. For Group 2, ablation was performed using the Rhythmia™ System with novel ablation catheter with a dedicated algorithm (DirectSense) used to measure LI at the distal electrode of this catheter. An absolute impedance drop greater than 20Ω was used at each targeted. According to the Close Protocol, ablation included a point by point pulmonary vein isolation (PVI) with an Inter-lesion space ≤5 mm in both Groups. Procedural endpoint was PVI, with confirmed bidirectional block. Results A total of 116 patients were enrolled, 59 patients in Group 1 (CF) and 57 in Group 2 (LI), 65 (63%) with a paroxismal AF and 36 (37%) with a persistent AF. Baseline patients features were not different between groups (P=ns). LI-Group showed a comparable procedural time (180±89 vs 180±56, P=0.59) but with a longer fluoroscopy time (20±12 vs 13±9 min, P=0.002). Wide antral isolation was more often observed in CF-Group (95% vs 80%, P=0.022), while LI-Group 2 required frequently additional right or left carina ablation (28% vs 14%, P=0.013). The mean LI was 106±14Ω prior to ablation and 92.5±11Ω after ablation (mean LI drop of 13.5±8Ω) during a median RF time of 26 [19–34] sec for each ablation spot. No steam pops or complications during the procedures were reported. The acute procedural success was 100%, with all PVs successfully isolated in all study patients. Regarding safety, only minor vascular complications were observed (5%), without differences between groups (p=0.97). During follow up, 9-month freedom from atrial fibrillation/atrial flutter/atrial tachycardia recurrence was 86% in Group 1 and 75% in Group 2 (P=0.2). Conclusions An LI-guided PV ablation strategy seems to be safe and effective, with acute and mid-term outcomes comparable to the current contact force strategy. LI monitoring could be a promising complementary parameter to evaluate not only wall contact but also lesion formation during power delivery. Procedural Outcomes Funding Acknowledgement Type of funding source: None





2015 ◽  
Vol 66 (16) ◽  
pp. C187-C188
Author(s):  
Caiyi Lu ◽  
Yuxiao Zhang ◽  
Rsn Zhang ◽  
Qiang Xu ◽  
Wei Yan ◽  
...  