scholarly journals GW26-e0088 Long Term Efficacy of Enhanced Ablation on PVA isolation using Remote Magnetic Navigation in Patients with Atrial Fibrillation

2015 ◽  
Vol 66 (16) ◽  
pp. C187-C188
Author(s):  
Caiyi Lu ◽  
Yuxiao Zhang ◽  
Rsn Zhang ◽  
Qiang Xu ◽  
Wei Yan ◽  
...  
2021 ◽  
Vol 10 (20) ◽  
pp. 4695
Author(s):  
Denise Guckel ◽  
Sarah Niemann ◽  
Marc Ditzhaus ◽  
Stephan Molatta ◽  
Leonard Bergau ◽  
...  

Remote magnetic navigation (RMN) facilitates ventricular arrhythmia (VA) ablation. This study aimed to evaluate the long-term efficacy of RMN-guided ablation for ventricular tachycardia (VT) and premature ventricular contractions (PVC). A total of 176 consecutive patients (mean age 53.23 ± 17.55 years, 37% female) underwent VA ablation for PVC (132 patients, 75%) or VT (44 patients, 25%). The cohort consisted of 119 patients (68%) with idiopathic VA, 31 (18%) with ischemic (ICM), and 26 (15%) with dilated cardiomyopathy (DCM). VA recurrence was observed in 69 patients (39%, mean age 51.71 ± 19.91 years, 23% female) during a follow-up period of 5.48 years (first quartile 770.50 days, second quartile 1101.50 days, third quartile 1615.50 days). Left ventricular ejection fraction <40% lead to a significantly increased risk for VA (p = 0.031*). Multivariate analyses found DCM to be an independent predictor (IP) for VA recurrence (p < 0.001*, hazard ratio (HR) 3.74, confidence interval (CI) 1.58–8.88). ICM resulted in a lower increase in VA recurrence (p = 0.221, HR 1.49, CI 0.79–2.81). Class I/III/IV antiarrhythmic drug therapy (AADs) was also identified as IP for recurrence (p = 0.030*, HR 2.48, CI 1.11–5.68). A total of 16 patients (9%) died within the observational period. RMN-guided ablation of VA lead to acceptable long-term results. An impaired LV function, DCM, and AADs were associated with a significant risk for VA recurrence. Personalized paths are needed to improve efficacy and outcome.


2018 ◽  
Vol 2018 ◽  
pp. 1-8
Author(s):  
Xiao-yu Liu ◽  
Hai-feng Shi ◽  
Jie Zheng ◽  
Ku-lin Li ◽  
Xiao-xi Zhao ◽  
...  

Objective. The objective of this study was to investigate the impact of left atrial (LA) size for the ablation of atrial fibrillation (AF) using remote magnetic navigation (RMN). Methods. A total of 165 patients with AF who underwent catheter ablation using RMN were included. The patients were divided into two groups based on LA diameter. Eighty-three patients had small LA (diameter <40 mm; Group A), and 82 patients had a large LA (diameter ≥40 mm; Group B). Results. During mapping and ablation, X-ray time (37.0 (99.0) s vs. 12 (30.1) s, P<0.001) and X-ray dose (1.4 (2.7) gy·cm2 vs. 0.7 (2.1) gy·cm2, P=0.013) were significantly higher in Group A. No serious complications occurred in any of the patients. There was no statistical difference in the rate of first anatomical attempt of pulmonary vein isolation between the two groups (71.1% vs. 57.3%, P=0.065). However, compared with Group B, the rate of sinus rhythm was higher (77.1% vs. 58.5%, P<0.001) during the follow-up period. More patients in Group A required a sheath adjustment (47/83 vs. 21/82, P<0.001), presumably due to less magnets positioned outside of the sheath. In vitro experiments with the RMN catheter demonstrated that only one magnet exposed created the sheath affects which influenced the flexibility of the catheter. Conclusions. AF ablation using RMN is safe and effective in both small and large LA patients. Patients with small LA may pose a greater difficulty when using RMN which may be attributed to the fewer magnets beyond the sheath. As a result, the exposure of radiation was increased. This study found that having at least two magnets of the catheter positioned outside of the sheath can ensure an appropriate flexibility of the catheter.


2019 ◽  
Vol 14 (1) ◽  
Author(s):  
John Johnkoski ◽  
Bryan Miles ◽  
Anna Sudbury ◽  
Mohammed Osman ◽  
Muhammad Bilal Munir ◽  
...  

Abstract Background The aim of this study is to report the long-term efficacy and safety of thoracoscopic epicardial left atrial ablation (TELA) in patients with paroxysmal atrial fibrillation (AF). Methods This was a retrospective review of medical records. We included all patients diagnosed with paroxysmal AF who underwent TELA at our institution between 04/2011 and 06/2017. TELA included pulmonary vein isolation, LA dome lesions and LA appendage exclusion. All (n = 55) patients received an implantable loop recorder (ILR), 30 days post-operatively. Antiarrhythmic and anticoagulation therapy were discontinued at 90 and 180 days postoperatively, respectively, if patients were free of AF recurrence. Failure was defined as ≥two minutes of continuous AF, or atrial tachycardia. Results Fifty-five patients (78% males, mean age = 61.6 years) qualified for the study. The average duration in AF was 3.64 +/− 3.4 years, mean CHA2DS2-VASc Score was 2.0 +/− 1.6. The procedure was attempted in 57 patients and completed successfully in 55 (96.5%). Two patients experienced a minor pulmonary vein bleed that was managed conservatively. Post procedure, one patient experienced pulmonary edema, another experienced a pneumothorax requiring a chest tube and another experienced acute respiratory distress syndrome resulting in longer hospitalization. Otherwise, there were no major procedural complications. Success rates were 89.1% (n = 49/55), 85.5% (n = 47/55) and 76.9% (n = 40/52) at 6, 12 and 24 months, respectively. In the multivariate cox-proportional hazard model, survival at the mean of covariates was 86 and 74% at 12 and 24 months, respectively. Conclusion In this single center experience, TELA was a safe and efficacious procedure for patients with paroxysmal AF.


EP Europace ◽  
2018 ◽  
Vol 20 (suppl_2) ◽  
pp. ii11-ii21 ◽  
Author(s):  
Pierre Qian ◽  
Kasun De Silva ◽  
Saurabh Kumar ◽  
Fazlur Nadri ◽  
Rahul Samanta ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document