Cheek Tooth Extraction Via a Minimally Invasive Transbuccal Approach and Intradental Screw Placement in 54 Equids

2015 ◽  
Vol 44 (8) ◽  
pp. 1012-1020 ◽  
Author(s):  
Frederik Langeneckert ◽  
Thomas Witte ◽  
Frank Schellenberger ◽  
Christian Czech ◽  
David Aebischer ◽  
...  
Author(s):  
Apipop Kritsaneephaiboon ◽  
Watit Wuttimanop ◽  
Surasak Jitprapaikulsarn ◽  
Pornpanit Dissaneewate ◽  
Chulin Chewakidakarn ◽  
...  

Neurosurgery ◽  
2019 ◽  
Vol 66 (Supplement_1) ◽  
Author(s):  
Guang-Ting Cong ◽  
Avani Vaishnav ◽  
Joseph Barbera ◽  
Hiroshi Kumagai ◽  
James Dowdell ◽  
...  

Abstract INTRODUCTION Posterior spinal instrumentation for fusion using intraoperative computed tomography (CT) navigation is gaining traction as an alternative to the conventional two-dimensional fluoroscopic-guided approach to percutaneous pedicle screw placement. However, few studies to date have directly compared outcomes of these 2 minimally invasive instrumentation methods. METHODS A consecutive cohort of patients undergoing primary percutaneous posterior lumbar spine instrumentation for spine fusion was retrospectively reviewed. Revision surgeries or cases converted to open were excluded. Accuracy of screw placement was assessed using a postoperative CT scan with blinding to the surgical methods used. The Gertzbein-Robbins classification was used to grade cortical breach: Grade 0 (<0 mm cortical breach), Grade I (<2 mm), Grade II (2-4 mm), Grade III (4-6 mm), and Grade IV (>6 mm). RESULTS CT navigation was found to significantly improve accuracy of screw placement (P < .022). There was significantly more facet violation of the unfused level in the fluoroscopy group vs the CT group (9% vs 0.5%; P < .0001). There was also a higher proportion of poor screw placement in the fluoroscopy group (10.1% vs 3.6%). No statistical difference was found in the rate of tip breach, inferomedial breach, or lateral breach. Regression analysis showed that fluoroscopy had twice the odds of incurring poor screw placement as compared to CT navigation. CONCLUSION This radiographic study comparing screw placement in minimally invasive fluoroscopy- vs CT navigation-guided lumbar spine instrumentation provides evidence that CT navigation significantly improves accuracy of screw placement, especially in optimizing the screw trajectory so as to avoid facet violation. Long-term follow-up studies should be performed to ascertain whether this difference can contribute to an improvement in clinical outcomes.


2020 ◽  
Vol 10 ◽  
pp. 191-194
Author(s):  
Roxana Rugina ◽  
Dan Lazar

The prosthodontic rehabilitation of edentulous spaces is a very common demand of patients. However, in the majority of cases, this is not as simple as it sounds. Because in time, the consequences of tooth extraction affect the neighboring teeth, leading to tooth migrations, tooth rotations, tilting, and the sagittal and vertical reduction of the edentulous spaces that have to be restored. Using segmental orthodontics on a limited number of teeth associated with skeletal anchorage, we can significantly improve the clinical situation, correcting these consequences of tooth migration following extraction, allowing the prosthodontist to have a better starting point in the process of rehabilitation. The treatment time is shorter than compared to a comprehensive orthodontic treatment, and thus, the patient acceptance may be increased. Once the spaces are correctly calibrated, and the tooth migrations have been corrected, the prosthodontist can restore the missing teeth as minimally invasive as possible.


2018 ◽  
Vol 31 (10) ◽  
pp. 523-529 ◽  
Author(s):  
A. A. Horbal ◽  
R. J. M. Reardon ◽  
T. Froydenlund ◽  
R. C. Jago ◽  
P. M. Dixon

2018 ◽  
Vol 16 (4) ◽  
pp. E121-E121 ◽  
Author(s):  
Corey T Walker ◽  
Jakub Godzik ◽  
David S Xu ◽  
Nicholas Theodore ◽  
Juan S Uribe ◽  
...  

Abstract Lateral interbody fusion has distinct advantages over traditional posterior approaches. When adjunctive percutaneous pedicle screw fixation is required, placement from the lateral decubitus position theoretically increases safety and improves operative efficiency by obviating the need for repositioning. However, safe cannulation of the contralateral, down-side pedicles remains technically challenging and often prohibitive. In this video, we present the case of a 59-yr-old man with refractory back pain and bilateral lower extremity radiculopathy that was worse on the left than right side. The patient provided written informed consent before undergoing treatment. We performed minimally invasive single-position lateral interbody fusion with robotic (ExcelsiusGPS, Globus Medical Inc, Audubon, Pennsylvania) bilateral percutaneous pedicle screw fixation for the treatment of asymmetric disc degeneration, dynamic instability, and left paracentral disc herniation with corresponding stenosis at the L3-4 level. A left-sided minimally invasive transpsoas lateral interbody graft was placed with fluoroscopic guidance. Without changing the position of the patient or breaking the sterile field, an intraoperative cone-beam computed tomography image was obtained for navigational screw placement with stereotactic trackers in the iliac spine. Screw trajectories were planned using the robotic navigation software and were placed percutaneously in the bilateral L3 and L4 pedicles using the robotic arm. Concomitant lateral fluoroscopy may be used if desired to ensure the fidelity of the robotic guidance. The patient recovered well postoperatively and was discharged home within 36 h, without complication. Single-position lateral interbody fusion and percutaneous pedicle screw fixation can be accomplished using robotic-assisted navigation and pedicle screw placement. Used with permission from Barrow Neurological Institute.


2020 ◽  
Vol 5 (4) ◽  
pp. 2473011420S0003
Author(s):  
Katherine M. Dederer ◽  
Patrick J. Maloney ◽  
John T. Campbell ◽  
Clifford L. Jeng ◽  
Rebecca A. Cerrato

Category: Bunion; Basic Sciences/Biologics Introduction/Purpose: Minimally-invasive surgery (MIS) for hallux valgus correction has become increasingly common. This technique involves an osteotomy of the first metatarsal, followed by fixation with two cannulated screws. Since screws are typically not bicortical, they rely upon bone quality within the metatarsal head for fixation strength. However, bone mineral density (BMD) within different regions of the metatarsal head is unknown. Measuring the BMD in the target region may predict the strength of the bone-screw fixation. Similar to previous work which determined the optimal position for lag screw placement in the femoral head during hip fracture fixation, this study aimed to determine average BMD within four quadrants of the metatarsal head using CT and thus predict the optimal trajectories for cannulated screws during the MIS bunion procedure. Methods: All patients between 18-75 years of age scheduled to undergo MIS hallux valgus correction by one of two surgeons experienced in the MIS technique were eligible to participate. Patients were excluded if they had a prior first metatarsal surgery, pre-existing hardware, previous first metatarsal fracture, or a history of osteoporosis treatment. Patients were enrolled prospectively, and a weight-bearing CT scan of the affected foot was obtained pre-operatively. Demographic factors including age, sex, laterality, body mass index (BMI), comorbidities, and smoking status as well as standard three-view weight-bearing radiographs were collected for all patients.Using the coronal CT slice at maximal metatarsal head diameter, each head was divided into equal quadrants. Hounsfield units (HU) within each quadrant were measured independently by three study investigators using our hospital’s radiology viewing software (Merge PACS; IBM Corporation, Armonk, NY), and these density measurements were averaged. Statistical analysis was conducted using ANOVA and Student’s t-test. Results: Fifteen patients were included for preliminary analysis. All patients were female. The average age was 45.7 years. 9 of the 15 included feet were right feet. Average BMI was 28.0. One patient reported active smoking prior to surgery. Comorbidities included obesity in three patients; none were diabetic. One had a history of diplegic cerebral palsy. The average HVA on a weight- bearing AP foot x-ray was 28.2°, and the average IMA was 12.6°. The BMD within the metatarsal head varied by quadrant, with the two combined dorsal quadrants having higher average BMD than the two combined plantar quadrants (122 vs 85 HU; p<0.001). The dorsal lateral quadrant had the highest average BMD of any quadrant (132 HU, p<0.001; Table 1). Conclusion: The density of the metatarsal head did vary by region within the head. The highest BMD was found in the dorsal lateral quadrant, and the lowest in the plantar lateral and plantar medial quadrants, which did not differ significantly from each other. Because strength of screw fixation is predicated upon screw design as well as bone density, these results suggest that surgeons may wish to direct screws toward the dorsolateral region of the metatarsal head in order to achieve optimal fixation. Further work is needed to determine whether this varies with patient age, gender, or hallux valgus angle. [Table: see text]


Dental Update ◽  
2013 ◽  
Vol 40 (4) ◽  
pp. 325-330 ◽  
Author(s):  
Daniel Saund ◽  
Thomas Dietrich

Sign in / Sign up

Export Citation Format

Share Document