Behavior of Eccentrically Loaded Plain and Steel Fiber Reinforced Concrete Filled Steel Box Columns

2013 ◽  
Vol 61 (3) ◽  
Author(s):  
Hanan Hussien Eltobgy ◽  
Ibrahim Galal Shaaban

The present study investigates the behavior of steel fiber reinforced concrete filled steel box columns (SFRCFSBC) targeting to enhance their strength. A nonlinear finite element model using ANSYS program has been developed to investigate the structural behavior of the inspected columns. The results obtained from that model has been compared with those calculated using Euro code (EC4), AISC/LRFD (2005) and the Egyptian Code of Practice for Steel Construction (ECPSC/LRFD 2007). The comparison indicated that the results of the model have been evaluated to an acceptable limit of accuracy. A parametric study was carried out to investigate the effect of wall thickness, column slenderness and percentage of steel fiber in concrete on the ultimate strength of composite columns. Confinement of the concrete core provided by the steel case was also investigated. It can be concluded from the results that a considerable increase in compressive and flexural strength may be gained by increasing the steel fiber percentage up to 4%. The highest rate of increase in strength for long columns was about 20% by using steel fiber percentage between 0.5% and 1.0%, while for short and medium columns was about 10% by using steel fiber percentage between 1% and 2%.

2017 ◽  
Vol 59 (7-8) ◽  
pp. 653-660 ◽  
Author(s):  
Wang Yan ◽  
Ge Lu ◽  
Chen Shi Jie ◽  
Zhou Li ◽  
Zhang Ting Ting

2021 ◽  
pp. 136943322098165
Author(s):  
Hossein Saberi ◽  
Farzad Hatami ◽  
Alireza Rahai

In this study, the co-effects of steel fibers and FRP confinement on the concrete behavior under the axial compression load are investigated. Thus, the experimental tests were conducted on 18 steel fiber-reinforced concrete (SFRC) specimens confined by FRP. Moreover, 24 existing experimental test results of FRP-confined specimens tested under axial compression are gathered to compile a reliable database for developing a mathematical model. In the conducted experimental tests, the concrete strength was varied as 26 MPa and 32.5 MPa and the steel fiber content was varied as 0.0%, 1.5%, and 3%. The specimens were confined with one and two layers of glass fiber reinforced polymer (GFRP) sheet. The experimental test results show that simultaneously using the steel fibers and FRP confinement in concrete not only significantly increases the peak strength and ultimate strain of concrete but also solves the issue of sudden failure in the FRP-confined concrete. The simulations confirm that the results of the proposed model are in good agreement with those of experimental tests.


1984 ◽  
Vol 21 (3) ◽  
pp. 108-111
Author(s):  
V. S. Sterin ◽  
V. A. Golubenkov ◽  
G. S. Rodov ◽  
B. V. Leikin ◽  
L. G. Kurbatov

Sign in / Sign up

Export Citation Format

Share Document