TRANSIENT THERMAL PERFORMANCE PREDICTION METHOD FOR PARABOLIC TROUGH SOLAR COLLECTOR UNDER FLUCTUATING SOLAR RADIATION

2016 ◽  
Vol 78 (5-9) ◽  
Author(s):  
Tohru Suwa ◽  
ShyeYunn Heng

As the effect of the global warming is becoming noticeable, the importance for environmental sustainability has been raised. Parabolic trough solar thermal collector system, which is one of the solutions to reduce the carbon dioxide emission, is a mature technology for electricity generation. Malaysia is a tropical country with long daytime, which makes suitable for solar thermal applications with parabolic trough solar thermal collectors. However, the high humidity causes the solar radiation to fluctuate. In order to simulate the solar thermal collectors’ performance at an early design stage of solar thermal power generation systems, fast still accurate transient thermal performance prediction methodis required. Although multiple transient thermal simulation methodologies exist, they are not suited especially at an early design stage where quick but reasonably accurate thermal performance prediction is needed because of their long calculation time.  In this paper, a transient thermal prediction method is developed to predict exit temperature of parabolic trough collectors under fluctuating solar radiation. The method is governed by simple summation operations and requires much less calculating time than the existing numerical methods. If the radiation heat loss at the parabolic trough collector tube surface is small, the working fluid temperature rise may be approximated as proportional to the receiving heat flux. The fluctuating solar radiation is considered as a series of heat flux pulses applied for a short period of time. The time dependent solar collector exit temperature is approximated by superimposing the exit temperature rise caused by each heat flux pulse. To demonstrate the capabilities of the proposed methodology, the solar collector exit temperature for one-day operation is predicted. The predicted solar collector exit temperature captures the trend of a finite element analysis result well. Still, the largest temperature difference is 38.8K and accuracy is not satisfactory. Currently, the accuracy of the proposed method is being improved. At the same time, its capabilities are being expanded. 

2011 ◽  
Vol 347-353 ◽  
pp. 812-821
Author(s):  
Zhong Zhu Qiu ◽  
Peng Li ◽  
Shao Lin Gong ◽  
Ye Wang ◽  
Wen Wen Guo ◽  
...  

To a closed type parabolic trough solar collector, thermal performance was analyzed, a mathematical model was set up, and test-bed of collector to heat efficiency test was built. According to the experiment test data, the accuracy of the thermal mathematics model was validated. The results show that the model simulation accuracy is so higher that the model is reasonable and available.


2020 ◽  
Vol 5 (2) ◽  
Author(s):  
Djamel Benmenine ◽  
Mokhtar Ghodbane

This study aims to conduct an experimental thermal examination of a parabolic trough collector in Ouargla region at Algeria, which will be used as a solar water heater. The solar collector was manufactured and then experimentally tested, as its theoretical optical performance was estimated at 75.06%, while the values of its true thermal performance are 10.61, 10.68 and 8.85 % for 13 May, 14 May and 15 May. Although its thermal performance is somewhat low, the studied PTC is effective in heating the water, whereas, using a volumetric flow of 0.011 l/s, about 317 liters of water can be heated daily at 42°C, knowing that the daily average consumption of hot water in a typical house is 250 liters because the Ouargla region is strategically located that receives huge amounts of solar irradiance


2021 ◽  
pp. 174425912110405
Author(s):  
Erlin Meng ◽  
Jiawang Yang ◽  
Ruonan Cai ◽  
Bo Zhou ◽  
Junqi Wang

Subtropical climate is characterized by high solar altitude angle in summer which causes the roof get more heat through solar radiation. GR, DSR, and CR all can decrease solar radiation heat gain of the roof. However, few researches have been done to the comparison of the thermal performance of these three roofs, especially in subtropical climate. In this study, four rooms were built separately with GR, DSR, CR, and ordinary roof (OR). The experiment was done from July 23 to August 4. Results showed that stabilities of the indoor air temperature of the four rooms were: DSR room > GR room > CR room > OR room. The GR, CR, and DSR can reduce the external surface temperature by 13.7°C, 12.0°C, and 4.8°C during the day while bring a temperature rise of 2.3°C, 1.9°C, and 0.9°C at night. Correlation analysis results showed that the internal surface heat flux of GR and DSR were negative correlated with weather factors while internal surface heat flux of OR and CR were positive correlated with weather factors. This study can give support to the selection between GR, DSR, and CR.


Sign in / Sign up

Export Citation Format

Share Document