Reduced Pressure Boiling Heat Transfer in Rectangular Microchannels With Interconnected Reentrant Cavities

2005 ◽  
Vol 127 (10) ◽  
pp. 1106-1114 ◽  
Author(s):  
Ali Koşar ◽  
Chih-Jung Kuo ◽  
Yoav Peles

Boiling flow of deionized water through 227μm hydraulic diameter microchannels with 7.5μm wide interconnected reentrant cavities at 47 kPa exit pressure has been investigated. Average two-phase heat transfer coefficients have been obtained over effective heat fluxes ranging from 28 to 445W∕cm2 and mass fluxes from 41 to 302kg∕m2s. A map is developed that divides the data into two regions where the heat transfer mechanisms are nucleation or convective boiling dominant. The map is compared to similar atmospheric exit pressure data developed in a previous study. A boiling mechanism transition criterion based on the Reynolds number and the Kandlikar k1 number is proposed.

2011 ◽  
Vol 133 (5) ◽  
Author(s):  
Saptarshi Basu ◽  
Sidy Ndao ◽  
Gregory J. Michna ◽  
Yoav Peles ◽  
Michael K. Jensen

An experimental study of two-phase heat transfer coefficients was carried out using R134a in uniformly heated horizontal circular microtubes with diameters from 0.50 mm to 1.60 mm over a range of mass fluxes, heat fluxes, saturation pressures, and vapor qualities. Heat transfer coefficients increased with increasing heat flux and saturation pressure but were independent of mass flux. The effects of vapor quality on heat transfer coefficients were less pronounced and varied depending on the quality. The data were compared with seven flow boiling correlations. None of the correlations predicted the experimental data very well, although they generally predicted the correct trends within limits of experimental error. A correlation was developed, which predicted the heat transfer coefficients with a mean average error of 29%. 80% of the data points were within the ±30% error limit.


Author(s):  
Jessica Sheehan ◽  
Avram Bar-Cohen

IR thermography of the heated wall for the two-phase flow of FC-72 in microgap channels provides explicit evidence of the quality-driven M-shaped variations in the two-phase microgap heat transfer coefficients. Data obtained from a 210μ microgap channel, operated with an FC-72 mass flux of 195 and 780 kg/m2-s and asymmetric heat fluxes of 28 W/cm2 to 35 W/cm2 are presented and discussed.


Author(s):  
Santosh Krishnamurthy ◽  
Yoav Peles

Flow boiling of water across a bank of circular staggered micro pin fins, 250 μm long and 100 μm diameter with pitch-to-diameter ratio of 1.5, was experimentally studied for mass fluxes ranging from 346 kg/m2s to 794 kg/m2s and surface heat fluxes ranging from 20 W/cm2 to 350 W/cm2. The local two-phase heat transfer coefficients were measured using thermistors located along the flow path of the channel. The flow was visualized and classified as vapor slug and annular flow patterns. Based on the observed flow patterns, the dominant heat transfer mechanism during boiling process was assumed to be convective boiling.


Author(s):  
Koichi Araga ◽  
Keisuke Okamoto ◽  
Keiji Murata

This paper presents an experimental investigation of the forced convective boiling of refrigerant HCFC123 in a mini-tube. The inner diameters of the test tubes, D, were 0.51 mm and 0.30 mm. First, two-phase frictional pressure drops were measured under adiabatic conditions and compared with the correlations for conventional tubes. The frictional pressure drop data were lower than the correlation for conventional tubes. However, the data were qualitatively in accord with those for conventional tubes and were correlated in the form φL2−1/Xtt. Next, heat transfer coefficients were measured under the conditions of constant heat flux and compared with those for conventional tubes and for pool boiling. The heat transfer characteristics for mini-tubes were different from those for conventional tubes and quite complicated. The heat transfer coefficients for D = 0.51 mm increased with heat flux but were almost independent of mass flux. Although the heat transfer coefficients were higher than those for a conventional tube with D = 10.3 mm and for pool boiling in the low quality region, they decreased gradually with increasing quality. The heat transfer coefficients for D = 0.30 mm were higher than those for D = 0.51 mm and were almost independent of both mass flux and heat flux.


2000 ◽  
Author(s):  
James S. Cotton ◽  
JenShih Chang ◽  
Mamdouh Shoukri ◽  
Tracey Smith-Pollard

Abstract In order to explore the mechanics of EHD induced flow and heat transfer augmentation, an experimental study of the tube-side boiling heat transfer of refrigerant HFC-134a has been conducted in a single-pass, counter-flow heat exchanger. The electrode position was arranged concentric to the tube. Experiments are conducted for inlet qualities of 0% to 60%, mass fluxes from 100 kg/m2s to 500 kg/m2s, heat fluxes of 10 kW/m2 and 20 kW/m2, and applied voltage from 0 kV to 8 kV DC. The threshold of EHD effects were analysed by a proposed dimensional analysis which predicts that the EHD forces become significant when the Dielectric Electric Rayleigh number is of the same order of magnitude as the square of the liquid Reynolds number, Eℓε ≈ Re ℓ 2 . This criterion is supported by experimental evidence. Flow visualization experiments have shown that, when the proposed dimensionless criterion is satisfied, EHD body forces may have a strong influence on the liquid-phase and consequently the flow pattern within the channel. The various flow configurations clearly affect heat transfer and pressure loss and need to be considered in any attempt to identify the effects of an applied electric field.


Author(s):  
Pega Hrnjak ◽  
Seongho Kim

Flow boiling heat transfer characteristics of CO2 with and without oil were investigated experimentally in horizontal smooth and enhanced tubes with an inner diameter of 11.2 mm. The visualization of flow pattern provides a detailed attributes of the nucleate and the convective boiling heat transfer. In order to investigate the effect of the miscible oil on the heat transfer of CO2, POE (polyolester) RENSIO C85E oil is added to give an oil circulation rate (OCR) between 0.5% and 2%. Results are compared with those of pure CO2. The experimental conditions include evaporation temperatures of −15 °C, mass fluxes from 40 to 200 kg/m2 s, heat fluxes from 0.5 to 10 kW/m2, and vapor qualities from 0.1 to 0.8. Oil generally deteriorates the heat transfer coefficient of pure CO2. The reduction in heat transfer coefficient is most apparent at low vapor qualities, 0.1 to 0.4, and at low mass fluxes, 100 and 200 kg/m2. It is caused by the suppression of nucleate boiling due to increased surface tension. At conditions where the convective boiling contribution is dominant, vapor qualities above 0.5, oil increases heat transfer coefficients. Through visualization, it is shown that the wetted area on the perimeter of inner tube is enhanced due to formation of foaming in the smooth tube. However, such enhancement of heat transfer due to forming is negligible in the enhanced tube, because the enhanced factor due to micro-finned structures is dominant.


Author(s):  
Seungwhan Baek ◽  
Sangkwon Jeong

Mixed Refrigerant Joule Thomson (MR-JT) refrigerators are widely used in various kinds of cryogenic systems these days. Although heat transfer coefficient estimation for a multiphase and multi-component fluid in cryogenic temperature range is necessarily required in the heat exchanger design of MR-JT refrigerator, it has been rarely discussed so far. In this paper, condensation and evaporation heat transfer coefficients of mixed refrigerant are measured in a microchannel heat exchanger. Printed Circuit Heat Exchanger (PCHE) has been developed as a compact microchannel heat exchanger and used in the experiment. Several two-phase heat transfer coefficient correlations are examined to discuss the experimental measurement results. The result of this paper shows that cryogenic mixed refrigerant heat transfer coefficients can be estimated by conventional two-phase heat transfer coefficient correlations.


Author(s):  
Jessica Sheehan ◽  
Avram Bar-Cohen

Heat transfer to an evaporating refrigerant and/or dielectric liquid in a microgap channel can provide very high heat transfer coefficients and volumetric cooling rates. Recent studies at Maryland have established the dominance of the annular flow regime in such microgap channels and related the observed high-quality peak of an M-shaped heat transfer coefficient curve to the onset of local dryout. The present study utilizes infrared thermography to locate such nascent dryout regions and operating conditions. Data obtained with a 210 micron microgap channel, operated with a mass flux of 195.2 kg/m2-s and heat fluxes of 10.3 to 26 W/cm2 are presented and discussed.


Author(s):  
Gilberto Moreno ◽  
Sreekant Narumanchi ◽  
Charles King

This fundamental study characterizes the pool boiling performance of a new refrigerant, HFO-1234yf (hydrofluoroolefin 2,3,3,3-tetrafluoropropene). The similarities in thermophysical properties with HFC-134a and low global warming potential make HFO-1234yf the prospective next generation refrigerant in automotive air-conditioning systems. This study examines the possibility of using this refrigerant for two-phase cooling of hybrid and electric vehicle power electronic components. Pool boiling experiments were conducted with HFO-1234yf and HFC-134a at system pressures ranging from 0.7 to 1.7 MPa using horizontally oriented 1 cm2 heat sources. Results show that the boiling heat transfer coefficients of HFO-1234yf and HFC-134a are nearly identical at lower heat fluxes. HFO-1234yf yielded lower heat transfer coefficients at higher heat fluxes and lower critical heat flux (CHF) as compared with HFC-134a. To enhance boiling heat transfer, a copper microporous coating was applied to the test surfaces. The coating provided enhancement to both the boiling heat transfer coefficients and CHF, for both refrigerants, at all tested pressures. Increasing pressure decreases the level of heat transfer coefficient enhancements while increasing the level of CHF enhancements.


Sign in / Sign up

Export Citation Format

Share Document