Loss Mechanisms in Shear-Force Pump With Multiple Corotating Disks

2014 ◽  
Vol 136 (8) ◽  
Author(s):  
Baotong Wang ◽  
Koji Okamoto ◽  
Kazuo Yamaguchi ◽  
Susumu Teramoto

In a shear-force pump with multiple corotating disks, the pressure gain is obtained by utilizing the shear force produced on the surfaces of the rotating disks. Thus, it is expected to have advantages as a microfluid device compared to a conventional bladed compressor or pump, which suffers greatly from viscous loss. However, in previous studies, a shear-force pump could not achieve high efficiency in experiments, even though very good efficiencies were predicted in numerical and analytical studies on the flow field between corotating disks. Therefore, the objective of the present work was to investigate the internal flow dynamics and clarify the loss mechanisms in a complete shear-force pump device consisting of both rotor and stationary components. In order to achieve this goal, a numerical simulation using an independent rotor analysis was first performed on the internal flow field between two corotating disks to evaluate the isentropic efficiency and pressure coefficient that could be achieved. Then, an experimental test rig for a shear-force pump was designed and built, and an experiment was carried out to determine the performance of a complete pump device with the same corotating disk design as the independent rotor analysis. In addition, a numerical simulation was executed for the flow field of a pump system consisting of both rotor and stationary components based on the present test rig to investigate the flow field and loss factors of this device. The results of this independent rotor analysis showed that the corotating disks can achieve a fairly high efficiency at a low flow coefficient with a high dynamic pressure, and the flow direction is extremely close to the tangential direction at the disk outlet, which caused difficulties in the design of the diffuser and scroll. In the experimental test, the high total pressure loss in the parallel diffuser and scroll parts was observed. This was found to be the result of the significant friction loss caused by the long flow path due to strong recirculation in the diffuser and scroll volute, which was found in the simulation results for the internal flow in the whole pump system. In addition, a reverse flow appeared in the rotor part at a low flow coefficient, which significantly deteriorated the rotor performance. These conclusions provided some clues for improving the performance of a shear-force pump device in future work.

1995 ◽  
Vol 117 (4) ◽  
pp. 585-592 ◽  
Author(s):  
J. Paroubek ◽  
V. Cyrus ◽  
J. Kyncˇl

Some results of a research and development program for centrifugal compressors are presented. Six-stage configurations with low flow coefficient were tested. The stages had channel width parameter b2/D2 = 0.01 and 0.03. For each value of the width parameter, three different impellers with inlet hub to outlet diameter ratio do/D2 = 0.3, 0.4, and 0.5 were designed. Test rig, instrumentation, and data analysis are described. Special attention was devoted to probe calibrations and to evaluation of the leakage, bearing, and disk friction losses. Aerodynamic performance of all tested stages is presented. Slip factors of impellers obtained experimentally and theoretically are compared. Losses in both vaneless diffuser and return channel with deswirl vanes are discussed. Rotating stall was also investigated. Criteria for stall limit were tested.


1994 ◽  
Author(s):  
J. Paroubek ◽  
V. Cyrus ◽  
J. Kyncl

Some results of a research and development programme for centrifugal compressors are presented. Six stage configurations with low flow coefficient were tested. The stages had channel width parameter bo/D2=0.01 and 0.03. For each value of the width parameter three different impellers with inlet hub to outlet diameter ratio do/D2=0.3, 0.4 and 0.5 were designed. Test rig, instrumentation and data analysis are described. Special attention was devoted to probe calibrations and to evaluation of the leakage, bearing and disc friction losses. Aerodynamic performance of all tested stages is presented. Slip factors of impellers obtained experimentally and theoretically are compared. Losses in both vaneless diffuser and return channel with de-swirl vanes are discussed. Rotating stall was also investigated. Criteria for stall limit were tested.


2013 ◽  
Vol 299 ◽  
pp. 52-55
Author(s):  
Ye Zun Sun ◽  
Jun Qi Qin ◽  
Chang Chun Di ◽  
Kai Bo Cui ◽  
Yu Liang Yang

It takes much less than the model test and can give a detailed description of the internal details of the internal flow field of recoil mechanism that use computational fluid dynamics theory and numerical simulation do research. It has the advantages of low cost, accurate calculation, high efficiency, easy to implement and so on. This article provides a brief introduction to the current situation and development outlook of the simulation study of the recoil mechanism using of computational fluid dynamics.


Author(s):  
C. Xu ◽  
R. S. Amano

A low flow coefficient unshrouded centrifugal compressor would give up clearance very large in relation to the span of the blades, because centrifugal compressors produce a sufficiently large pressure rise in fewer stages. This problem is more acute for a low flow high-pressure ratio impeller. The large tip clearance would cause flow separations, and as a result it would drop both the efficiency and surge margin. Thus a design of a high efficiency and wide operation range for a low flow coefficient centrifugal compressor is a great challenge. This paper describes a new development of high efficiency and large surge margin low flow coefficient (0.145) centrifugal compressor. A viscous turbomachinery optimal design method developed by the authors for axial flow machine was further extended and used in this centrifugal compressor design. The new compressor has three main parts: impeller, a low solidity diffuser and volute. The tip clearance is under a special consideration in this design to allow impeller insensitiveness to the clearance. A three-dimensional low solidity diffuser design method is proposed and applied to this design. This design is successful to extend the low solidarity diffusers to high-pressure ratio compressor. It is demonstrated that the design is in a great success. The design performance range of the total to static efficiency of the compressor is about 85% and stability range is over 35%. The experimental results showed that the test results are in good agreement with the design.


Author(s):  
C. Xu ◽  
R. S. Amano

A low flow coefficient unshrouded centrifugal compressor would give up clearance very large in relation to the span of the blades, because centrifugal compressors produce a sufficiently large pressure rise in fewer stages. This problem is more acute for a low flow high-pressure ratio impeller. The large tip clearance would cause flow separations, and as a result it would drop both the efficiency and surge margin. Thus a design of a high efficiency and wide operation range for a low flow coefficient centrifugal compressor is a great challenge. This paper describes a new development of high efficiency and large surge margin low flow coefficient (0.145) centrifugal compressor. A viscous turbomachinery optimal design method developed by the authors for axial flow machine was further extended and used in this centrifugal compressor design. The new compressor has three main parts: impeller, a low solidity diffuser and volute. The tip clearance is under a special consideration in this design to allow impeller insensitiveness to the clearance. A three-dimensional low solidity diffuser design method is proposed and applied to this design. This design is successful to extend the low solidarity diffusers to high-pressure ratio compressor. It is demonstrated that the design is in a great success. The design performance range of the total to static efficiency of the compressor is about 85% and stability range is over 35%. The experimental results showed that the test results are in good agreement with the design.


Author(s):  
Fabian Dietmann ◽  
Michael Casey ◽  
Damian M. Vogt

Abstract Further validation of an analytic method to calculate the influence of changes in Reynolds number, machine size and roughness on the performance of axial and radial turbocompressors is presented. The correlation uses a dissipation coefficient as a basis for scaling the losses with changes in relative roughness and Reynolds number. The original correlation from Dietmann and Casey [6] is based on experimental data and theoretical models. Evaluations of five numerically calculated compressor stages at different flow coefficients are presented to support the trends of the correlation. It is shown that the sensitivity of the compressor performance to Reynolds and roughness effects is highest for low flow coefficient radial stages and steadily decreases as the design flow coefficient of the stage and the hydraulic diameter of the flow channels increases.


2016 ◽  
Vol 88 (3) ◽  
pp. 237-253 ◽  
Author(s):  
Nicholus Tayari Akankwasa ◽  
Huiting Lin ◽  
Yuze Zhang ◽  
Jun Wang

In order to regulate turbulence strength and determine airflow characteristics in a new dual-feed rotor spinning unit, the internal flow field is investigated. A computational fluid dynamics technique is employed to numerically study the three-dimensional model of the internal airflow in the new design. The effects of air velocity variation on turbulence strength, negative pressure, Re, and wall pressure distribution are investigated based on simulation data and previous studies. The results show that the turbulence strength and Re increased with increase in inlet air velocity. Pressure profiles inside the rotor varied significantly with positive pressure observed at the channel exits. Minimal inlet velocity maintains the flow field in the rotor interior below 100 m/s, which gives the ideal turbulence required to minimize yarn quality deterioration. The dual-feed rotor spinning unit showed more orderly streamline patterns with fewer vortices compared to the conventional one. The numerical simulation can provide insights on airflow studies and some guidelines for future prototyping and experiments to further improve the new design.


Sign in / Sign up

Export Citation Format

Share Document