Defining the Relationship of Magnetohydrodynamic Voltages and Magnetic Field Strength

Author(s):  
Kevin J. Wu ◽  
T. Stan Gregory ◽  
Michael C. Lastinger ◽  
Brian Boland ◽  
Zion Tsz Ho Tse

The magnetohydrodynamic (MHD) effect is observed in flowing electrolytic fluids and their interactions with magnetic fields. The magnetic field (B0), when perpendicular with the electrolytic fluid flow (μ), causes the shift of the charged particles in the fluid to shift across the length of the vessel (L) normal to the plane of B0 and flow, creating a voltage (VMHD) observable through voltage potential measurements across the flow (Eqn. 1)[1].(1)VMHD=∫0Lu⇀×B0⇀·dL⇀In the medical field, this phenomenon is commonly encountered inside of a human body inside of an MRI machine (Fig. 1). The effect appears most prominently inside the aortic arch due to orientation and size, and is a large contributing factor to noise observed in intra-MRI ECGs [2, 3]. Traditionally, this MHD induced voltage (VMHD) was filtered out to obtain clean intra-MRI ECGs, but recent studies have shown that the VMHD induced in a vessel is related to the blood flow through it (stroke volume in the case of the aortic arch) [4]. Further proof of this relationship can be shown from the increase in VMHD measured from periphery blood vessels during periods of elevated heart rate from exercise stress, when compared to baseline state [5]. Previously, a portable device was built to utilize induced VMHD as an indicator of flow [6]. The device was capable of showing change in blood flow, utilizing a blood flow metric obtained from VMHD, however a quantitative relationship between VMHD and blood flow has yet to be established. This study aims to define the relationship between induced VMHD and magnetic field strength in a controlled setting. Through modulating the distance between a pair of magnets around a flow channel, we hope to better realize the relationship between magnetic field strength and induced VMHD with constant flow and electrolytic solution concentration.

1993 ◽  
Vol 10 (4) ◽  
pp. 275-277
Author(s):  
J.O. Murphy ◽  
J.M. Lopez ◽  
C.P. Dyt

AbstractThe effect of varying magnetic field strength on the frequency of oscillatory motions for cellular multimode magnetoconvection has been investigated. In addition the influence of the thermal, viscous and magnetic diffusivities have been taken into account and the range of preferred horizontal scales established. The relationship between the period of oscillation and the magnetic field strength is determined.


2021 ◽  
Vol 63 (5) ◽  
pp. 283-288
Author(s):  
Entao Yao ◽  
Fei Han ◽  
Ping Wang ◽  
Yuan Zhang

Non-destructive testing (NDT) involving stress measurement has found a wide range of applications in rail, pipeline, bridge and other engineering areas and it is therefore necessary to find a method to measure stress. In this paper, a non-destructive method is proposed to measure stress by observation of the magnetostrictive properties of the objects. Stress in the elastic range is applied to the ferromagnetic material, changing its lattice, while stress in the plastic range changes its microstructure. These are the reasons for the magnetostrictive coefficient variation of the material. An experimental platform was set up, using a cantilever beam with a strain gauge, to study the relationship between the SH wave, the static magnetic field strength and the applied uniaxial stress. The curve obtained shows the relationship between the amplitude of the electromagnetic acoustic transducer (EMAT) signal and the static magnetic field strength. The magnetostrictive parameters, sensitive to stress, were extracted from the curve. This method is verified through trials on test samples with a maximum relative error between experimental and predicted values of 8.06%.


2009 ◽  
Vol 497 (1) ◽  
pp. 273-285 ◽  
Author(s):  
M. Loukitcheva ◽  
S. K. Solanki ◽  
S. M. White

2013 ◽  
Vol 135 (11) ◽  
Author(s):  
Aiman Alshare ◽  
Bourhan Tashtoush ◽  
Hossam H. El-Khalil

Steady flow simulations of blood flow in an axisymmetric stenosed artery, subjected to a static magnetic field, are performed to investigate the influence of artery size, magnetic field strength, and non-Newtonian behavior on artery wall shear stress and pressure drop in the stenosed section. It is found that wall shear stress and pressure drop increase by decreasing artery size, assuming non-Newtonian fluid, and increasing magnetic field strength. In the computations, the shear thinning behavior of blood is accounted for by the Carreau–Yasuda model. Computational results are compared and found to be inline with available experimental data.


1976 ◽  
Vol 32 ◽  
pp. 613-622
Author(s):  
I.A. Aslanov ◽  
Yu.S. Rustamov

SummaryMeasurements of the radial velocities and magnetic field strength of β CrB were carried out. It is shown that there is a variability with the rotation period different for various elements. The curve of the magnetic field variation measured from lines of 5 different elements: FeI, CrI, CrII, TiII, ScII and CaI has a complex shape specific for each element. This may be due to the presence of magnetic spots on the stellar surface. A comparison with the radial velocity curves suggests the presence of a least 4 spots of Ti and Cr coinciding with magnetic spots. A change of the magnetic field with optical depth is shown. The curve of the Heffvariation with the rotation period is given. A possibility of secular variations of the magnetic field is shown.


Sign in / Sign up

Export Citation Format

Share Document