Cooling the Tip of a Turbine Blade Using Pressure Side Holes: Part 2 — Heat Transfer Measurements

Author(s):  
J. R. Christophel ◽  
K. A. Thole ◽  
F. J. Cunha

The clearance gap between a turbine blade tip and its associated shroud allows leakage flow across the tip gap from the pressure side to the suction side of the blade. Understanding how this leakage flow affects heat transfer is critical in extending blade tip durability in terms of oxidation, erosion, clearance, and overall turbine performance. This paper is the second of a two part series that discusses the augmentation of tip heat transfer as a result of blowing from the pressure side of the tip as well as dirt purge holes placed on the tip. For the experimental investigation, three scaled-up blades were used to form a two-passage linear cascade in a low speed wind tunnel. The rig was designed to simulate different tip gap sizes and coolant flow rates. Heat transfer coefficients were quantified by measuring the total power supplied to a constant heat flux surface placed on the tip of the blade and measuring the tip temperatures. Results indicate that increased blowing leads to increased augmentations in tip heat transfer, particularly at the entrance region to the gap. When combined with adiabatic effectiveness measurements, the coolant from the pressure side holes provides an overall net heat flux reduction to the blade tip but is nearly independent of coolant flow levels.

2005 ◽  
Vol 127 (2) ◽  
pp. 278-286 ◽  
Author(s):  
J. R. Christophel ◽  
K. A. Thole ◽  
F. J. Cunha

The clearance gap between a turbine blade tip and its associated shroud allows leakage flow across the tip from the pressure side to the suction side of the blade. Understanding how this leakage flow affects heat transfer is critical in extending the durability of a blade tip, which is subjected to effects of oxidation and erosion. This paper is the second of a two-part series that discusses the augmentation of tip heat transfer coefficients as a result of blowing from film-cooling holes placed along the pressure side of a blade and from dirt purge holes placed on the tip. For the experimental investigation, three scaled-up blades were used to form a two-passage, linear cascade in a low-speed wind tunnel. The rig was designed to simulate different tip gap sizes and film-coolant flow rates. Heat transfer coefficients were quantified by using a constant heat flux surface placed along the blade tip. Results indicate that increased film-coolant injection leads to increased augmentation levels of tip heat transfer coefficients, particularly at the entrance region to the gap. Despite increased heat transfer coefficients, an overall net heat flux reduction to the blade tip results from pressure-side cooling because of the increased adiabatic effectiveness levels. The area-averaged results of the net heat flux reduction for the tip indicate that there is (i) little dependence on coolant flows and (ii) more cooling benefit for a small tip gap relative to that of a large tip gap.


2005 ◽  
Vol 127 (2) ◽  
pp. 251-262 ◽  
Author(s):  
J. R. Christophel ◽  
E. Couch ◽  
K. A. Thole ◽  
F. J. Cunha

The clearance gap between the tip of a turbine blade and the shroud has an inherent leakage flow from the pressure side to the suction side of the blade. This leakage flow of combustion gas and air mixtures leads to severe heat transfer rates on the blade tip of the high-pressure turbine. As the thermal load to the blade increases, blade alloy oxidation and erosion rates increase thereby adversely affecting component life. The subject of this paper is the cooling effectiveness levels and heat transfer coefficients that result from blowing through two holes placed in the forward region of a blade tip. These holes are referred to as dirt purge holes and are generally required for manufacturing purposes and expelling dirt from the coolant flow when operating in sandy environments. Experiments were performed in a linear blade cascade for two tip-gap heights over a range of blowing ratios. Results indicated that the cooling effectiveness was highly dependent on the tip-gap clearance with better cooling achieved at smaller clearances. Also, heat transfer was found to increase with blowing. In considering an overall benefit of cooling from the dirt purge blowing, a large benefit was realized for a smaller tip gap as compared with a larger tip gap.


Author(s):  
J. Christophel ◽  
E. Couch ◽  
K. A. Thole ◽  
F. J. Cunha

The clearance gap between the tip of a turbine blade and the shroud has an inherent leakage flow from the pressure side to the suction side of the blade. This leakage flow of combustion gas and air mixtures leads to severe heat transfer rates on the blade tip of the high pressure turbine. As the thermal load to the blade increases, blade alloy oxidation and erosion rates increase thereby adversely affecting component life. The subject of this paper is the cooling effectiveness levels and heat transfer coefficients that result from blowing through two holes placed in the forward region of a blade tip. These holes are referred to as dirt purge holes and are generally required for manufacturing purposes and expelling dirt from the coolant flow when operating in sandy environments. Experiments were performed in a linear blade cascade for two tip gap heights over a range of blowing ratios. Results indicated that the cooling effectiveness was highly dependent upon the tip gap clearance with better cooling achieved at smaller clearances. Also, heat transfer was found to increase with blowing. In considering an overall benefit of cooling from the dirt purge blowing, a large benefit was realized for a smaller tip gap as compared with a larger tip gap.


Author(s):  
K. Anto ◽  
S. Xue ◽  
W. F. Ng ◽  
L. J. Zhang ◽  
H. K. Moon

This study focuses on local heat transfer characteristics on the tip and near-tip regions of a turbine blade with a flat tip, tested under transonic conditions in a stationary, 2-D linear cascade with high freestream turbulence. The experiments were conducted at the Virginia Tech transonic blow-down wind tunnel facility. The effects of tip clearance and exit Mach number on heat transfer distribution were investigated on the tip surface using a transient infrared thermography technique. In addition, thin film gages were used to study similar effects in heat transfer on the near-tip regions at 94% height based on engine blade span of the pressure and suction sides. Surface oil flow visualizations on the blade tip region were carried-out to shed some light on the leakage flow structure. Experiments were performed at three exit Mach numbers of 0.7, 0.85, and 1.05 for two different tip clearances of 0.9% and 1.8% based on turbine blade span. The exit Mach numbers tested correspond to exit Reynolds numbers of 7.6 × 105, 9.0 × 105, and 1.1 × 106 based on blade true chord. The tests were performed with a high freestream turbulence intensity of 12% at the cascade inlet. Results at 0.85 exit Mach showed that an increase in the tip gap clearance from 0.9% to 1.8% translates into a 3% increase in the average heat transfer coefficients on the blade tip surface. At 0.9% tip clearance, an increase in exit Mach number from 0.85 to 1.05 led to a 39% increase in average heat transfer on the tip. High heat transfer was observed on the blade tip surface near the leading edge, and an increase in the tip clearance gap and exit Mach number augmented this near-leading edge tip heat transfer. At 94% of engine blade height on the suction side near the tip, a peak in heat transfer was observed in all test cases at s/C = 0.66, due to the onset of a downstream leakage vortex, originating from the pressure side. An increase in both the tip gap and exit Mach number resulted in an increase, followed by a decrease in the near-tip suction side heat transfer. On the near-tip pressure side, a slight increase in heat transfer was observed with increased tip gap and exit Mach number. In general, the suction side heat transfer is greater than the pressure side heat transfer, as a result of the suction side leakage vortices.


Author(s):  
Sumanta Acharya ◽  
Huitao Yang ◽  
Chander Prakash ◽  
Ron Bunker

Numerical calculations are performed to explore different strategies for reducing tip leakage flow and heat transfer on the GE-E3 High-Pressure-Turbine (HPT) rotor blade. The calculations are performed for a single blade with periodic conditions imposed along the two boundaries in the circumferential-pitch direction. Several leakage reduction strategies are considered, all for a tip-clearance of 1.5% of the blade span, a pressure ratio (ratio of inlet total pressure to exit static pressure) of 1.2, and an inlet turbulence level of 6.1%. The first set of leakage reduction strategies explored include different squealer tip configurations: pressure-side squealer, suction-side squealer, mean-camber line squealer, and pressure plus suction side squealers located either along the edges of the blade or moved inwards. The suction-side squealer is shown to have the lowest heat transfer coefficient distribution and the lowest leakage flow rates. Two tip-desensitization strategies are explored. The first strategy involves a pressure-side winglet shaped to be thickest at the location with the largest pressure difference across the blade. The second strategy involves adding inclined ribs on the blade tip with the ribs normal to the local flow direction. While both strategies lead to reduction in the leakage flow and tip heat transfer rates, the ribbed tip exhibits considerably lower heat transfer coefficients. In comparing the two desensitization schemes with the various squealer tip configurations, the suction side squealer still exhibits the lowest heat transfer coefficient and leakage flow rates.


2002 ◽  
Vol 124 (3) ◽  
pp. 452-459 ◽  
Author(s):  
Gm Salam Azad ◽  
Je-Chin Han ◽  
Ronald S. Bunker ◽  
C. Pang Lee

This study investigates the effect of a squealer tip geometry arrangement on heat transfer coefficient and static pressure distributions on a gas turbine blade tip in a five-bladed stationary linear cascade. A transient liquid crystal technique is used to obtain detailed heat transfer coefficient distribution. The test blade is a linear model of a tip section of the GE E3 high-pressure turbine first stage rotor blade. Six tip geometry cases are studied: (1) squealer on pressure side, (2) squealer on mid camber line, (3) squealer on suction side, (4) squealer on pressure and suction sides, (5) squealer on pressure side plus mid camber line, and (6) squealer on suction side plus mid camber line. The flow condition during the blowdown tests corresponds to an overall pressure ratio of 1.32 and exit Reynolds number based on axial chord of 1.1×106. Results show that squealer geometry arrangement can change the leakage flow and results in different heat transfer coefficients to the blade tip. A squealer on suction side provides a better benefit compared to that on pressure side or mid camber line. A squealer on mid camber line performs better than that on a pressure side.


2001 ◽  
Author(s):  
Gm Salam Azad ◽  
Je-Chin Han ◽  
Ronald S. Bunker ◽  
C. Pang Lee

Abstract This study investigates the effect of a squealer tip geometry arrangement on heat transfer coefficient and static pressure distributions on a gas turbine blade tip in a five-bladed stationary linear cascade. A transient liquid crystal technique is used to obtain detailed heat transfer coefficient distribution. The test blade is a linear model of a tip section of the GE E3 high-pressure turbine first stage rotor blade. Six tip geometry cases are studied: 1) squealer on pressure side, 2) squealer on mid camber line, 3) squealer on suction side, 4) squealer on pressure and suction sides, 5) squealer on pressure side plus mid camber line, and 6) squealer on suction side plus mid camber line. The flow condition corresponds to an overall pressure ratio of 1.32 and exit Reynolds number based on axial chord of 1.1 × 106. Results show that squealer geometry arrangement can change the leakage flow and results in different heat transfer coefficients to the blade tip. A squealer on suction side provides a better benefit compared to that on pressure side or mid camber line. A squealer on mid camber line performs better than that on a pressure side.


Author(s):  
Devin O’Dowd ◽  
Qiang Zhang ◽  
Phil Ligrani ◽  
Li He ◽  
Stefan Friedrichs

The present study considers spatially-resolved surface heat transfer coefficients and adiabatic wall temperatures on a turbine blade tip in a linear cascade under transonic conditions. Six different measurement and processing techniques are considered and compared, including transient infrared thermography and thin-film heat flux gauges. Three methods use the same experimental setup, using a heater mesh to provide a near-instantaneous step-change in mainstream temperature, employing an infrared camera to measure surface temperature. The three methods use the same data but different processing techniques to determine the heat transfer coefficients and adiabatic wall temperatures. Two methods use different processing techniques to reconstruct heat flux from the temperature time trace measured. A plot of the heat flux versus temperature is used to determine the heat transfer coefficients and adiabatic wall temperatures. The third uses the classical solution to the 1-D non-steady Fourier equation to determine heat transfer coefficients and adiabatic wall temperatures. A fourth method uses regression analysis to calculate detailed heat transfer coefficients for a quasi-steady state condition using a thin-foil heater on the tip surface. The fifth method uses the infrared camera to measure the adiabatic wall temperature surface distribution of a blade tip after a quasi-steady state condition is present. Finally, the sixth method employs thin-film gauges to measure surface temperature histories at four discreet blade tip locations. With this approach, heat flux reconstruction is used to calculate the transient heat transfer coefficients and adiabatic wall temperatures. Overall, the present study shows that the infrared thermography technique with heat flux reconstruction using the Impulse method, is the most accurate and reliable method to obtain detailed, spatially-resolved heat transfer coefficients and adiabatic wall temperatures on a turbine blade tip in a linear cascade.


Author(s):  
Jae Su Kwak ◽  
Jaeyong Ahn ◽  
Je-Chin Han ◽  
C. Pang Lee ◽  
Robert Boyle ◽  
...  

Detailed heat transfer coefficient distributions on a gas turbine squealer tip blade were measured using a hue detection based transient liquid crystals technique. The heat transfer coefficients on the shroud and near tip regions of the pressure and suction sides of a blade were also measured. Squealer rims were located along (a) the camber line, (b) the pressure side, (c) the suction side, (d) the pressure and suction sides, (e) the camber line and the pressure side, and (f) the camber line and the suction side, respectively. Tests were performed on a five-bladed linear cascade with a blow down facility. The Reynolds number based on the cascade exit velocity and the axial chord length of a blade was 1.1×106 and the overall pressure ratio was 1.2. Heat transfer measurements were taken at the three tip gap clearances of 1.0%, 1.5% and 2.5% of blade span. Results show that the heat transfer coefficients on the blade tip and the shroud were significantly reduced by using a squealer tip blade. Results also showed that a different squealer geometry arrangement changed the leakage flow path and resulted in different heat transfer coefficient distributions. The suction side squealer tip provided the lowest heat transfer coefficient on the blade tip and near tip regions compared to the other squealer geometry arrangements.


2010 ◽  
Vol 133 (2) ◽  
Author(s):  
D. O. O’Dowd ◽  
Q. Zhang ◽  
L. He ◽  
P. M. Ligrani ◽  
S. Friedrichs

The present study considers spatially resolved surface heat transfer coefficients and adiabatic wall temperatures on a turbine blade tip in a linear cascade under transonic conditions. Five different measurement and processing techniques using infrared thermography are considered and compared. Three transient methods use the same experimental setup, using a heater mesh to provide a near-instantaneous step-change in mainstream temperature, employing an infrared camera to measure surface temperature. These three methods use the same data but different processing techniques to determine the heat transfer coefficients and adiabatic wall temperatures. Two of these methods use different processing techniques to reconstruct heat flux from the temperature time trace measured. A plot of the heat flux versus temperature is used to determine the heat transfer coefficients and adiabatic wall temperatures. The third uses the classical solution to the 1D nonsteady Fourier equation to determine heat transfer coefficients and adiabatic wall temperatures. The fourth method uses regression analysis to calculate detailed heat transfer coefficients for a quasi-steady-state condition using a thin-foil heater on the tip surface. Finally, the fifth method uses the infrared camera to measure the adiabatic wall temperature surface distribution of a blade tip after a quasi-steady-state condition is present. Overall, the present study shows that the infrared thermography technique with heat flux reconstruction using the impulse method is the most accurate, computationally efficient, and reliable method to obtain detailed, spatially resolved heat transfer coefficients and adiabatic wall temperatures on a transonic turbine blade tip in a linear cascade.