Effects of Hot Streaks on Adiabatic Effectiveness for a Film Cooled Turbine Vane

Author(s):  
Krishnakumar Varadarajan ◽  
David G. Bogard

Turbine guide vanes in gas turbine engines are typically subjected to localized “hot streaks” emanating from the combustor. This experimental program examined how these hot streaks affect the film cooling performance for these vanes. Adiabatic effectiveness tests were conducted on the showerhead and suction side regions of the vane. Particular attention was placed on how to scale that adiabatic effectiveness data obtained with a hot streak to correctly predict the adiabatic effectiveness. Thermal field measurements were made to determine the temperature gradients for the hot streak near the wall. These experiments showed that the effect of the hot streak on the adiabatic effectiveness could be accounted for by using an “adjusted” mainstream temperature equal to the hot streak temperature at the wall of the vane.

Author(s):  
Joshua B. Anderson ◽  
James R. Winka ◽  
David G. Bogard ◽  
Michael E. Crawford

The leading edge of a turbine vane is subject to some of the highest temperature loading within an engine, and an accurate understanding of leading edge film coolant behavior is essential for modern engine design. Although there have been many investigations of the adiabatic effectiveness for showerhead film cooling of a vane leading edge region, there have been no previous studies in which individual rows of the showerhead were tested with the explicit intent of validating superposition models. For the current investigation, a series of adiabatic effectiveness experiments were performed with a five-row and three-row showerhead. The experiments were repeated separately with each individual row of holes active. This allowed evaluation of superposition methods on both the suction side of the vane, which was moderately convex, and the pressure side of the vane, which was mildly concave. Superposition was found to accurately predict performance on the suction side of the vane at lower momentum flux ratios, but not at higher momentum flux ratios. On the pressure side of the vane the superposition predictions were consistently lower than measured values, with significant errors occurring at the higher momentum flux ratios. Reasons for the under-prediction by superposition analysis are presented.


2006 ◽  
Vol 129 (2) ◽  
pp. 294-302 ◽  
Author(s):  
Scot K. Waye ◽  
David G. Bogard

Adiabatic film cooling effectiveness of axial holes embedded within a transverse trench on the suction side of a turbine vane was investigated. High-resolution two-dimensional data obtained from infrared thermography and corrected for local conduction provided spatial adiabatic effectiveness data. Flow parameters of blowing ratio, density ratio, and turbulence intensity were independently varied. In addition to a baseline geometry, nine trench configurations were tested, all with a depth of 1∕2 hole diameter, with varying widths, and with perpendicular and inclined trench walls. A perpendicular trench wall at the very downstream edge of the coolant hole was found to be the key trench characteristic that yielded much improved adiabatic effectiveness performance. This configuration increased adiabatic effectiveness up to 100% near the hole and 40% downstream. All other trench configurations had little effect on the adiabatic effectiveness. Thermal field measurements confirmed that the improved adiabatic effectiveness that occurred for a narrow trench with perpendicular walls was due to a lateral spreading of the coolant and reduced coolant jet separation. The cooling levels exhibited by these particular geometries are comparable to shaped holes, but much easier and cheaper to manufacture.


Author(s):  
Scot K. Waye ◽  
David G. Bogard

Film cooling adiabatic effectiveness for axial and compound angle holes on the suction side of a simulated turbine vane was investigated to determine the relative performance of these configurations. The effect of the surface curvature was also evaluated by comparing to previous curvature studies and flat plate film cooling results. Experiments were conducted for varying coolant density ratio, mainstream turbulence levels, and hole spacing. Results from these measurements showed that for mild curvature, 2r/d ≈ 160, flat plate results are sufficient to predict the cooling effectiveness. Furthermore, the compound angle injection improves adiabatic effectiveness for higher blowing ratios, similar to previous studies using flat plate facilities.


2015 ◽  
Vol 137 (7) ◽  
Author(s):  
John W. McClintic ◽  
Sean R. Klavetter ◽  
James R. Winka ◽  
Joshua B. Anderson ◽  
David G. Bogard ◽  
...  

In gas turbine engines, film cooling holes are often fed by an internal crossflow, with flow normal to the direction of the external flow around the airfoil. Many experimental studies have used a quiescent plenum to feed model film cooling holes and thus do not account for the effects of internal crossflow. In this study, an experimental flat plate facility was constructed to study the effects of internal crossflow on a row of cylindrical compound angle film cooling holes. There are relatively few studies available in literature that focus on the effects of crossflow on film cooling performance, with no studies examining the effects of internal crossflow on film cooling with round, compound angled holes. A crossflow channel allowed for coolant to flow alternately in either direction perpendicular to the mainstream flow. Experimental conditions were scaled to match realistic turbine engine conditions at low speeds. Cylindrical compound angle film cooling holes were operated at blowing ratios ranging from 0.5 to 2.0 and at a density ratio (DR) of 1.5. The results from the crossflow experiments were compared to a baseline plenum-fed configuration. This study showed that significantly greater adiabatic effectiveness was achieved for crossflow counter to the direction of coolant injection.


2006 ◽  
Vol 129 (2) ◽  
pp. 202-211 ◽  
Author(s):  
Scot K. Waye ◽  
David G. Bogard

Film cooling adiabatic effectiveness for axial and compound angle holes on the suction side of a simulated turbine vane was investigated to determine the relative performance of these configurations. The effect of the surface curvature was also evaluated by comparing to previous curvature studies and flat plate film cooling results. Experiments were conducted for varying coolant density ratio, mainstream turbulence levels, and hole spacing. Results from these measurements showed that for mild curvature, 2r∕d≈160, flat plate results are sufficient to predict the cooling effectiveness. Furthermore, the compound angle injection improves adiabatic effectiveness for higher blowing ratios, similar to previous studies using flat plate facilities.


Author(s):  
Scot K. Waye ◽  
David G. Bogard

Adiabatic film cooling effectiveness of axial holes embedded within a transverse trench on the suction side of a turbine vane was investigated. High resolution two dimensional data obtained from IR thermography and corrected for local conduction provided spatial adiabatic effectiveness data. Flow parameters of blowing ratio, density ratio, and turbulence intensity were independently varied. In addition to a baseline geometry, nine trench configurations were tested, all with a depth of 1/2 hole diameter, with varying widths, and with perpendicular and inclined trench walls. A perpendicular trench wall at the very downstream edge of the coolant hole was found to be the key trench characteristic that yielded much improved adiabatic effectiveness performance. This configuration increased adiabatic effectiveness up to 100% near the hole and 40% downstream. All other trench configurations had little effect on the adiabatic effectiveness. Thermal field measurements confirmed that the improved adiabatic effectiveness that occurred for a narrow trench with perpendicular walls was due a lateral spreading of the coolant and reduced coolant jet separation. The cooling levels exhibited by these particular geometries are comparable to shaped holes, but much easier and cheaper to manufacture.


2005 ◽  
Vol 128 (3) ◽  
pp. 547-554 ◽  
Author(s):  
James L. Rutledge ◽  
David Robertson ◽  
David G. Bogard

After an extended period of operation, the surfaces of turbine airfoils become extremely rough due to deposition, spallation, and erosion. The rough airfoil surfaces will cause film cooling performance degradation due to effects on adiabatic effectiveness and heat transfer coefficients. In this study, the individual and combined effects of roughness upstream and downstream of a row of film cooling holes on the suction side of a turbine vane have been determined. Adiabatic effectiveness and heat transfer coefficients were measured for a range of mainstream turbulence levels and with and without showerhead blowing. Using these parameters, the ultimate film cooling performance was quantified in terms of net heat flux reduction. The dominant effect of roughness was a doubling of the heat transfer coefficients. Maximum adiabatic effectiveness levels were also decreased significantly. Relative to a film cooled smooth surface, a film cooled rough surface was found to increase the heat flux to the surface by 30%–70%.


Author(s):  
J. Michael Cutbirth ◽  
David G. Bogard

This study focused on the film cooling performance on the pressure side of a turbine vane subjected to high mainstream turbulence levels, with and without showerhead blowing. Whereas previous studies have measured the adiabatic effectiveness and heat transfer at the surface of the airfoil, the goal of this study was to examine the flow and thermal fields above the surface. These measurements included flow visualization, thermal profiles, and laser Doppler velocimetry. For comparison, adiabatic effectiveness was also measured. A mainstream turbulence level of Tu∞ = 20%, with integral length scale of seven hole diameters, was used. Particularly insightful is the discovery that the large scale high mainstream turbulence causes a lateral oscillation of coolant jet resulting in a much wider time average distribution of coolant. Even with high mainstream turbulence, showerhead blowing was found to still cause a significantly increased dispersion of the pressure side coolant jets.


2015 ◽  
Vol 137 (4) ◽  
Author(s):  
Joshua B. Anderson ◽  
James R. Winka ◽  
David G. Bogard ◽  
Michael E. Crawford

The leading edge of a turbine vane is subject to some of the highest temperature loading within an engine, and an accurate understanding of leading edge film coolant behavior is essential for modern engine design. Although there have been many investigations of the adiabatic effectiveness for showerhead film cooling of a vane leading edge region, there have been no previous studies in which individual rows of the showerhead were tested with the explicit intent of validating superposition models. For the current investigation, a series of adiabatic effectiveness experiments were performed with a five-row and three-row showerhead. The experiments were repeated separately with each individual row of holes active. This allowed evaluation of superposition methods on both the suction side of the vane, which was moderately convex, and the pressure side of the vane, which was mildly concave. Superposition was found to accurately predict performance on the suction side of the vane at lower momentum flux ratios, but not at higher momentum flux ratios. On the pressure side of the vane, the superposition predictions were consistently lower than measured values, with significant errors occurring at the higher momentum flux ratios. Reasons for the underprediction by superposition analysis are presented.


Author(s):  
James L. Rutledge ◽  
David Robertson ◽  
David G. Bogard

After an extended period of operation, the surfaces of turbine airfoils become extremely rough due to deposition, spallation, and erosion. The rough airfoil surfaces will cause film cooling performance degradation due to effects on adiabatic effectiveness and heat transfer coefficients. In this study, the individual and combined effects of roughness upstream and downstream of a row of film cooling holes on the suction side of a turbine vane have been determined. Adiabatic effectiveness and heat transfer coefficients were measured for a range of mainstream turbulence levels and with and without showerhead blowing. Using these parameters, the ultimate film cooling performance was quantified in terms of net heat flux reduction. The dominant effect of roughness was a doubling of the heat transfer coefficients. Maximum adiabatic effectiveness levels were also decreased significantly. Relative to a film cooled smooth surface, a film cooled rough surface was found to increase the heat flux to the surface by 30% to 70%.


Sign in / Sign up

Export Citation Format

Share Document