Combustor Heat Shield Impingement Cooling and its Effect on Liner Convective Heat Transfer for a Model Annular Combustor With Radial Swirlers

Author(s):  
David Gomez-Ramirez ◽  
Deepu Dilip ◽  
Bharath Viswanath Ravi ◽  
Samruddhi Deshpande ◽  
Jaideep Pandit ◽  
...  

Increasing pressure to reduce pollutant emissions such as NOx and CO, while simultaneously increasing the efficiency of gas turbines, has led to the development of modern gas turbine combustors operating at lean equivalence ratios and high compression ratios. These modern combustors use a large portion of the compressor air in the combustion process and hence efficient use of cooling air is critical. Backside impingement cooling is one alternative for advanced cooling in gas turbine combustors. The dome of the combustor is a primary example where backside impingement cooling is extensively used. The dome directly interacts with the flame and hence represents a limiting factor for combustor durability. The present paper studies two aspects of dome cooling: the impingement heat transfer on the dome heat shield of an annular combustor and the effect of the outflow from the spent air on the liner heat transfer. A transient measurement technique using Thermochromic Liquid Crystals (TLCs) was used to characterize the convective heat transfer coefficient on the backside of an industrial heat shield design provided by Solar Turbines, Inc. for Reynolds numbers (with respect to the hole diameter) of ∼ 1500 and ∼ 2500. Reynolds-Averaged Navier Stokes (RANS) calculations using the k-ω SST turbulence model were found to be in good agreement with the experiment. A standard heat transfer correlation for impingement hole arrays overestimated the mean heat transfer coefficient compared to the experiment and computations, however this could be explained by low biases in the results. Steady state IR measurements were performed to study the effects that the spent air from the heat shield impingement cooling had on the liner convective heat transfer. Measurements were taken for three Reynolds numbers (with respect to the hydraulic diameter of the combustor annulus) including 50000, 90000, and 130000. A downstream shift in the flow features was observed due to the secondary flow introduced by the outflow, as well as a significant increase in the convective heat transfer close to the dome wall.

2014 ◽  
Vol 137 (3) ◽  
Author(s):  
Ignacio Mayo ◽  
Tony Arts ◽  
Ahmed El-Habib ◽  
Benjamin Parres

The convective heat transfer distribution in a rib-roughened rotating internal cooling channel was measured for different rotation and Reynolds numbers, representative of engine operating conditions. The test section consisted of a channel of aspect ratio equal to 0.9 with one wall equipped with eight ribs perpendicular to the main flow direction. The pitch to rib height ratio was 10 and the rib blockage was 10%. The test rig was designed to provide a uniform heat flux boundary condition over the ribbed wall, minimizing the heat transfer losses and allowing temperature measurements at significant rotation rates. Steady-state liquid crystal thermography (LCT) was employed to quantify a detailed 2D distribution of the wall temperature, allowing the determination of the convective heat transfer coefficient along the area between the sixth and eighth rib. The channel and all the required instrumentation were mounted on a large rotating disk, providing the same spatial resolution and measurement accuracy as in a stationary rig. The assembly was able to rotate both in clockwise and counterclockwise directions, so that the investigated wall was acting either as leading or trailing side, respectively. The tested Reynolds number values (based on the hydraulic diameter of the channel) were 15,000, 20,000, 30,000, and 40,000. The maximum rotation number values were ranging between 0.12 (Re = 40,000) and 0.30 (Re = 15,000). Turbulence profiles and secondary flows modified by rotation have shown their impact not only on the average value of the heat transfer coefficient but also on its distribution. On the trailing side, the heat transfer distribution flattens as the rotation number increases, while its averaged value increases due to the turbulence enhancement and secondary flows induced by the rotation. On the leading side, the secondary flows counteract the turbulence reduction and the overall heat transfer coefficient exhibits a limited decrease. In the latter case, the secondary flows are responsible for high heat transfer gradients on the investigated area.


Author(s):  
Ignacio Mayo ◽  
Ahmed El-Habib ◽  
Tony Arts ◽  
Benjamin Parres

The convective heat transfer distribution in a rib-roughened rotating internal cooling channel was measured for different Rotation and Reynolds numbers, representative of engine operating conditions. The test section consisted of a channel of aspect ratio equal to 0.9 with one wall equipped with 8 ribs perpendicular to the main flow direction. The pitch to rib height ratio was 10 and the rib blockage was 10 per cent. The test rig was designed to provide a uniform heat flux boundary condition over the ribbed wall, minimizing the heat transfer losses and allowing temperature measurements at significant rotation rates. Steady-state Liquid Crystal Thermography was employed to quantify a detailed two dimensional distribution of the wall temperature, allowing the determination of the convective heat transfer coefficient along the area between the 6th and 8th rib. The channel and all the required instrumentation were mounted on a large rotating disk, providing the same spatial resolution and measurement accuracy as in a stationary rig. The assembly was able to rotate both in clockwise and counterclockwise directions, so that the investigated wall was acting either as leading or trailing side, respectively. The tested Reynolds number values (based on the hydraulic diameter of the channel) were 15000, 20000, 30000 and 40000. The maximum Rotation number values were ranging between 0.12 (Re = 40000) and 0.30 (Re = 15000). Turbulence profiles and secondary flows modified by rotation have shown their impact not only on the average value of the heat transfer coefficient but also on its distribution. On the trailing side, the heat transfer distribution flattens as the Rotation number increases, while its averaged value increases due to the turbulence enhancement and secondary flows induced by the rotation. On the leading side, the secondary flows counteract the turbulence reduction and the overall heat transfer coefficient exhibits a limited decrease. In the latter case the secondary flows are responsible for high heat transfer gradients on the investigated area.


2015 ◽  
Vol 2015 ◽  
pp. 1-16
Author(s):  
T. Astarita ◽  
G. Cardone ◽  
L. de Luca ◽  
G. M. Carlomagno

This paper reviews some experimental measurements of convective heat transfer coefficient distributions which are connected with the cooling of gas turbines, performed by the authors’ research group at the University of Naples Federico II with infrared thermography. Measurements concern impinging jets, cooling of rotating disks, and gas turbine blades, which are either stationary or rotating. The heated thin foil sensor, associated with the detection of surface temperature by means of infrared thermography, is exploited to accurately measure detailed convective heat transfer coefficient maps. The paper also intends to show how to correctly apply the infrared technique in a variety of gas turbines cooling problems.