Pressure Drop in a Capillary Tube in Boiling Two-Phase Flow

Author(s):  
Fumito Kaminaga ◽  
Baduge Sumith ◽  
Kunihito Matsumura

Two-phase pressure drop is experimentally examined in a flow boiling condition in a tube of diameter 1.45 mm using water in ranges of pressure from 10 to 100 kPa, mass flux from 18 to 152 kg/m2s, heat flux from 13 to 646 kW/m2, and exit quality from 0.02 to 0.77. Also, pressure drop in an adiabatic air-water two-phase flow is measured at atmospheric pressure using the same test section and mass flux ranges of liquid and gas as those in the flow boiling. Decreasing system pressure the pressure drop significantly increases at a given mass flux. Influence of vapor phase on the pressure drop is found to be large both in the adiabatic and the diabatic conditions. The frictional pressure drop correlation for the adiabatic two-phase flow is developed and applied to predict pressure drop in the flow boiling. But it cannot give satisfactory predictions. The Chisholm correlation calculating a two-phase pressure drop multiplier is modified to account the influence of vapor phase in a capillary tube and the modified correlation can predict the pressure drop in the flow boiling within an error of 20%.

2016 ◽  
Vol 818 ◽  
pp. 23-27
Author(s):  
Agus Sunjarianto Pamitran ◽  
Nasruddin ◽  
Helmi Dadang Ardiansyah ◽  
Muhammad Idrus Alhamid

The characteristics of two-phase flow boiling of R-290 are required for replacing R-22 that has been phased-out. The present study focuses on experimental pressure drop for R-22 and R-290. The experiment was run with heat flux of 5.09 kW/m2 to 19.03 kW/m2, mass flux of 114.91 kg/m2s to 751.74 kg/m2s and saturation temperature of 4.77°C to 18.12°C. The present result showed that pressure drop was affected by heat flux, mass flux and saturation temperature. Lower mass flux, heat flux and saturation temperature results in lower pressure drop. The pressure drop of R-290 is lower than that of R-22. Among the existing pressure drop prediction methods, Lokhart-Martinelli (1949) gives the best prediction for the present pressure drop data.


Author(s):  
Ruosu Wang ◽  
Changhong Peng ◽  
Tao Zhou ◽  
Shichao Wang

In this paper, according to a separated phase flow model for annular two-phase flow in the vertical annular channel, the liquid film thickness, void fraction and two-phase pressure drop along the flow channel are predicted. The calculated pressure drop values are compared with that measured in experiment in the range of mass flux from 38.8 to 163.1kg/m2s; pressure from 1.5 to 6.0 MPa; and heat flux from 4.9 to 50.7kW/m2 for inside tube and from 4.2 to 78.8kW/m2 for outside tube. It can be found that the model can predict the pressure drop well. With the mass flux increasing and the gap of the annular channel decreasing, pressure drop increases.


2018 ◽  
Vol 189 ◽  
pp. 06010
Author(s):  
Qiaoyu Zhang ◽  
Jianjun Liu

The flow boiling instability characteristics of nitrogen flow boiling in a horizontal small diameter tube were numerically studied, and a numerical model coupled with two phase flow boiling and system flow supplying was developed. With the steady state solution of the model, the flow boiling characteristic curve and flow supplying curve were obtained. The flow boiling characteristic curve was affected by the heat flux and inlet subcooling, meanwhile the flow supplying curve was affected by the total system pressure drop and friction feature of the flow supplying section. With the transient solution of the model, The dynamical response of pressure drop oscillations type (PDOs) instability of two phase flow were investigated, occurring region and trigging conditions were also obtained.


Micromachines ◽  
2021 ◽  
Vol 12 (5) ◽  
pp. 510
Author(s):  
Yan Huang ◽  
Bifen Shu ◽  
Shengnan Zhou ◽  
Qi Shi

In this paper, two-phase pressure drop data were obtained for boiling in horizontal rectangular microchannels with a hydraulic diameter of 0.55 mm for R-134a over mass velocities from 790 to 1122, heat fluxes from 0 to 31.08 kW/m2 and vapor qualities from 0 to 0.25. The experimental results show that the Chisholm parameter in the separated flow model relies heavily on the vapor quality, especially in the low vapor quality region (from 0 to 0.1), where the two-phase flow pattern is mainly bubbly and slug flow. Then, the measured pressure drop data are compared with those from six separated flow models. Based on the comparison result, the superficial gas flux is introduced in this paper to consider the comprehensive influence of mass velocity and vapor quality on two-phase flow pressure drop, and a new equation for the Chisholm parameter in the separated flow model is proposed as a function of the superficial gas flux . The mean absolute error (MAE ) of the new flow correlation is 16.82%, which is significantly lower than the other correlations. Moreover, the applicability of the new expression has been verified by the experimental data in other literatures.


2007 ◽  
Vol 2 ◽  
pp. 25-32 ◽  
Author(s):  
Toru SUKAWA ◽  
Tomoya HASEGAWA ◽  
Kenji YOSHIDA ◽  
Isao KATAOKA

2016 ◽  
Vol 78 (8-4) ◽  
Author(s):  
Agus Sunjarianto Pamitran ◽  
Sentot Novianto ◽  
Normah Mohd-Ghazali ◽  
Nasruddin Nasruddin ◽  
Raldi Koestoer

Two-phase flow boiling pressure drop experiment was conducted to observe its characteristics and to develop a new correlation of void fraction based on the separated model. Investigation is completed on the natural refrigerant R-290 (propane) in a horizontal circular tube with a 7.6 mm inner diameter under experimental conditions of 3.7 to 9.6 °C saturation temperature, 10 to 25 kW/m2 heat flux, and 185 to 445 kg/m2s mass flux. The present experimental data was used to obtain the calculated void fraction which then was compared to the predicted void fraction with 31 existing correlations. A new void fraction correlation for predicting two-phase flow boiling pressure drop, as a function of Reynolds numbers, was proposed. The measured pressure drop was compared to the predicted pressure drop with some existing pressure drop models that use the newly developed void fraction model. The homogeneous model of void fraction showed the best prediction with 2% deviation


Author(s):  
Cheol Huh ◽  
Moo Hwan Kim

With a single microchannel and a series of microheaters made with MEMS technique, two-phase pressure drop and local flow boiling heat transfer were investigated using deionized water in a single horizontal rectangular microchannel. The test microchannel has a hydraulic diameter of 100 μm and length of 40 mm. A real time observation of the flow patterns with simultaneous measurement are made possible. Tests are performed for mass fluxes of 90, 169, and 267 kg/m2s and heat fluxes of from 100 to 600 kW/m2. The experimental local flow boiling heat transfer coefficients and two-phase frictional pressure gradient are evaluated and the effects of heat flux, mass flux, and vapor qualities on flow boiling are studied. Both the evaluated experimental data are compared with existing correlations. The experimental heat transfer coefficients are nearly independent on mass flux and the vapor quality. Most of all correlations do not provide reliable heat transfer coefficients predictions with vapor quality and prediction accuracy. As for two-phase pressure drop, the measured pressure drop increases with the mass flux and heat flux. Most of all existing correlations of two-phase frictional pressure gradient do not predict the experimental data except some limited conditions.


2004 ◽  
Vol 126 (3) ◽  
pp. 288-300 ◽  
Author(s):  
Weilin Qu ◽  
Seok-Mann Yoon ◽  
Issam Mudawar

Knowledge of flow pattern and flow pattern transitions is essential to the development of reliable predictive tools for pressure drop and heat transfer in two-phase micro-channel heat sinks. In the present study, experiments were conducted with adiabatic nitrogen-water two-phase flow in a rectangular micro-channel having a 0.406×2.032mm2 cross-section. Superficial velocities of nitrogen and water ranged from 0.08 to 81.92 m/s and 0.04 to 10.24 m/s, respectively. Flow patterns were first identified using high-speed video imaging, and still photos were then taken for representative patterns. Results reveal the dominant flow patterns are slug and annular, with bubbly flow occurring only occasionally; stratified and churn flow were never observed. A flow pattern map was constructed and compared with previous maps and predictions of flow pattern transition models. Features unique to two-phase micro-channel flow were identified and employed to validate key assumptions of an annular flow boiling model that was previously developed to predict pressure drop and heat transfer in two-phase micro-channel heat sinks. This earlier model was modified based on new findings from the adiabatic two-phase flow study. The modified model shows good agreement with experimental data for water-cooled heat sinks.


1995 ◽  
Author(s):  
F. Ohene ◽  
C. Livingston ◽  
C. Matthews ◽  
Y. Rhone

Sign in / Sign up

Export Citation Format

Share Document