Pressure Drop of Two-Phase Flow Boiling with R-22 and R-290 in 7.6 mm Diameter Tube

2016 ◽  
Vol 818 ◽  
pp. 23-27
Author(s):  
Agus Sunjarianto Pamitran ◽  
Nasruddin ◽  
Helmi Dadang Ardiansyah ◽  
Muhammad Idrus Alhamid

The characteristics of two-phase flow boiling of R-290 are required for replacing R-22 that has been phased-out. The present study focuses on experimental pressure drop for R-22 and R-290. The experiment was run with heat flux of 5.09 kW/m2 to 19.03 kW/m2, mass flux of 114.91 kg/m2s to 751.74 kg/m2s and saturation temperature of 4.77°C to 18.12°C. The present result showed that pressure drop was affected by heat flux, mass flux and saturation temperature. Lower mass flux, heat flux and saturation temperature results in lower pressure drop. The pressure drop of R-290 is lower than that of R-22. Among the existing pressure drop prediction methods, Lokhart-Martinelli (1949) gives the best prediction for the present pressure drop data.

2016 ◽  
Vol 819 ◽  
pp. 371-375
Author(s):  
Agus Sunjarianto Pamitran ◽  
Sentot Novianto ◽  
T.A. Simanjuntak ◽  
Nasruddin ◽  
Muhammad Idrus Alhamid

This study experimentally investigated two-phase flow pressure drop of propane as refrigerant in horizontal small tube. Inner diameter and length of the tube were 7.6 mm and 1.07 m, respectively. In order to get pressure drop data, the experiment was conducted in various conditions of 10 to 25 kW m-2 heat flux, 200 to 628 kg m-2 s-1 mass flux, and 4.0 to 11.7°C saturation temperature. This study clearly showed the effect of heat flux, mass flux, and saturation temperature on the pressure drop of propane. This study also investigated which fluid properties gave higher effect on the frictional pressure drop due to its change over the process based on the recent experiment data. The existing pressure drop correlations were evaluated against the experimental result.


2016 ◽  
Vol 78 (8-4) ◽  
Author(s):  
Agus Sunjarianto Pamitran ◽  
Sentot Novianto ◽  
Normah Mohd-Ghazali ◽  
Nasruddin Nasruddin ◽  
Raldi Koestoer

Two-phase flow boiling pressure drop experiment was conducted to observe its characteristics and to develop a new correlation of void fraction based on the separated model. Investigation is completed on the natural refrigerant R-290 (propane) in a horizontal circular tube with a 7.6 mm inner diameter under experimental conditions of 3.7 to 9.6 °C saturation temperature, 10 to 25 kW/m2 heat flux, and 185 to 445 kg/m2s mass flux. The present experimental data was used to obtain the calculated void fraction which then was compared to the predicted void fraction with 31 existing correlations. A new void fraction correlation for predicting two-phase flow boiling pressure drop, as a function of Reynolds numbers, was proposed. The measured pressure drop was compared to the predicted pressure drop with some existing pressure drop models that use the newly developed void fraction model. The homogeneous model of void fraction showed the best prediction with 2% deviation


Author(s):  
H. Y. Wu ◽  
Ping Cheng

A simultaneous visualization and measurement study has been carried out to investigate flow boiling of water in the 8 parallel silicon microchannels heated from below. It is found that there are two large-amplitude/long-period oscillating boiling modes exist in microchannels depending on the amounts of heat flux and mass flux. When the outlet water temperature is at saturation temperature and the wall temperatures are superheated, while the inlet water temperature is still subcooled, a Liquid/Two-phase Alternating Flow (LTAF) mode appears in the microchannels. This LTAF mode disappears when the inlet temperatures reaches the saturation temperature. As the heat flux is further increased such that the outlet water is superheated while the inlet water temperature is oscillating between subcooled and saturation temperature, a Liquid/Two-phase/Vapor Alternating Flow (LTVAF) mode begins. During these two unstable boiling modes, there are large-amplitude and long-period oscillations of water and wall temperatures with respect to time. Bubbly flow as well as some peculiar two-phase flow pattern are observed during the two-phase flow periods of the two unstable modes in the microchannels.


Author(s):  
Fumito Kaminaga ◽  
Baduge Sumith ◽  
Kunihito Matsumura

Two-phase pressure drop is experimentally examined in a flow boiling condition in a tube of diameter 1.45 mm using water in ranges of pressure from 10 to 100 kPa, mass flux from 18 to 152 kg/m2s, heat flux from 13 to 646 kW/m2, and exit quality from 0.02 to 0.77. Also, pressure drop in an adiabatic air-water two-phase flow is measured at atmospheric pressure using the same test section and mass flux ranges of liquid and gas as those in the flow boiling. Decreasing system pressure the pressure drop significantly increases at a given mass flux. Influence of vapor phase on the pressure drop is found to be large both in the adiabatic and the diabatic conditions. The frictional pressure drop correlation for the adiabatic two-phase flow is developed and applied to predict pressure drop in the flow boiling. But it cannot give satisfactory predictions. The Chisholm correlation calculating a two-phase pressure drop multiplier is modified to account the influence of vapor phase in a capillary tube and the modified correlation can predict the pressure drop in the flow boiling within an error of 20%.


Author(s):  
Tie Jun Zhang ◽  
Siyu Chen ◽  
Evelyn N. Wang

Two-phase microchannel cooling promises high heat flux removal for high-performance electronics and photonics. However, the heat transfer performance of flow boiling microchannels is limited by the critical heat flux (CHF) conditions. For variable heat inputs and variable fluid flows, it is essential to predict CHFs accurately for effective and efficient two-phase microchannel cooling. To characterize the CHF and pressure drop in flow boiling microchannels, a separated-flow model is proposed in this paper based on fundamental two-phase flow mass, energy, momentum conservation and wall energy conservation laws. With this theoretical framework, the relationship among liquid/vapor interfacial instability, two-phase flow characteristics and CHF is further studied. This mechanistic model also provides insight into the design and operational guidelines for advanced electronics and photonics cooling technologies.


Author(s):  
Ruosu Wang ◽  
Changhong Peng ◽  
Tao Zhou ◽  
Shichao Wang

In this paper, according to a separated phase flow model for annular two-phase flow in the vertical annular channel, the liquid film thickness, void fraction and two-phase pressure drop along the flow channel are predicted. The calculated pressure drop values are compared with that measured in experiment in the range of mass flux from 38.8 to 163.1kg/m2s; pressure from 1.5 to 6.0 MPa; and heat flux from 4.9 to 50.7kW/m2 for inside tube and from 4.2 to 78.8kW/m2 for outside tube. It can be found that the model can predict the pressure drop well. With the mass flux increasing and the gap of the annular channel decreasing, pressure drop increases.


2021 ◽  
Vol 5 (4) ◽  
pp. 31
Author(s):  
Seth Eckels ◽  
Zayed Ahmed ◽  
Molly Ross ◽  
Daniel Franken ◽  
Steven Eckels ◽  
...  

Recent studies have shown that the presence of dissolved salts in water can exhibit peculiar flow boiling and two-phase flow regimes. Two-phase flow and convective flow boiling are typically characterized with the help of void fraction measurements. To quantitatively improve our understanding of two-phase flow and boiling phenomenon with seawater coolant, void fraction data are needed, which can not be obtained from optical imaging. In this paper, we present experimental void fraction measurements of saturated flow boiling of tap water and seawater using X-ray radiography. X-rays with a maximum energy level of 40 KeV were used for imaging the exit region of the heated test section. At lower heat flux levels, the two phase flow in seawater was bubbly and homogeneous in nature, resulting in higher void fractions as compared to tap water. With an increase in heat flux, the flow regime was similar to slug flow, and void fraction measurements approached similarity with tap water. The predicted pressure drop using the measured void faction shows good agreement with the measured total pressure drop across the test section, demonstrating the validity of the measurement process.


Micromachines ◽  
2021 ◽  
Vol 12 (5) ◽  
pp. 510
Author(s):  
Yan Huang ◽  
Bifen Shu ◽  
Shengnan Zhou ◽  
Qi Shi

In this paper, two-phase pressure drop data were obtained for boiling in horizontal rectangular microchannels with a hydraulic diameter of 0.55 mm for R-134a over mass velocities from 790 to 1122, heat fluxes from 0 to 31.08 kW/m2 and vapor qualities from 0 to 0.25. The experimental results show that the Chisholm parameter in the separated flow model relies heavily on the vapor quality, especially in the low vapor quality region (from 0 to 0.1), where the two-phase flow pattern is mainly bubbly and slug flow. Then, the measured pressure drop data are compared with those from six separated flow models. Based on the comparison result, the superficial gas flux is introduced in this paper to consider the comprehensive influence of mass velocity and vapor quality on two-phase flow pressure drop, and a new equation for the Chisholm parameter in the separated flow model is proposed as a function of the superficial gas flux . The mean absolute error (MAE ) of the new flow correlation is 16.82%, which is significantly lower than the other correlations. Moreover, the applicability of the new expression has been verified by the experimental data in other literatures.


Sign in / Sign up

Export Citation Format

Share Document