Characteristics of Inclined Fin-Tube Heat Exchanger for Compact Air Conditioner

Author(s):  
Haruaki Kanematsu ◽  
Kazuhiko Murakami

For saving space at an office or a clean room, it is needed to reduce the space of an air conditioner. It is effective to miniaturize a heat exchanger because it occupies the large space in the air conditioner. Three types of a heat exchanger that are an in-line tube and cut fins type, a staggered tube and cut fins type and a staggered tube and uncut fins type were investigated as four inclined angle tests of 0, 45, 60 and 80 degrees in a heat wind tunnel. The coefficients of flow friction and heat transfer rates were obtained from these experiments, and the characteristics of inclined heat exchanger were clarified by effects of tube arrangements, fin types and inclined angles against flow direction. As a numerical approach, two-dimensional steady models were applied on the staggered tube and the in-line tube by using BFC (Boundary-Fitted Coordinate Method); BFC is available to make grids for any install angle of the heat exchanger. The results of the numerical analysis visualized flow patterns and heat transfer in these heat exchangers. In case of 80-degrees angle, the flow makes dead area in a part of the heat exchanger, and it causes reducing performance of the heat exchanger. These results are available for improve a compact high performance heat exchanger.

2002 ◽  
Vol 16 (1) ◽  
pp. 109-115 ◽  
Author(s):  
Seong-Yeon Yoo ◽  
Dong-Seong Park ◽  
Min-Ho Chung ◽  
Sang-Yun Lee

2021 ◽  
Vol 11 (19) ◽  
pp. 9261
Author(s):  
Yun-Seok Choi ◽  
Youn-Jea Kim

As electrical devices become smaller, it is essential to maintain operating temperature for safety and durability. Therefore, there are efforts to improve heat transfer performance under various conditions, such as using extended surfaces and nanofluids. Among them, cooling methods using ferrofluid are drawing the attention of many researchers. This fluid can control the movement of the fluid in magnetic fields. In this study, the heat transfer performance of a fin-tube heat exchanger, using ferrofluid as a coolant, was analyzed when external magnetic fields were applied. Permanent magnets were placed outside the heat exchanger. When the magnetic fields were applied, a change in the thermal boundary layer was observed. It also formed vortexes, which affected the formation of flow patterns. The vortex causes energy exchanges in the flow field, activating thermal diffusion and improving heat transfer. A numerical analysis was used to observe the cooling performance of heat exchangers, as the strength and number of the external magnetic fields were varying. VGs (vortex generators) were also installed to create vortex fields. A convective heat transfer coefficient was calculated to determine the heat transfer rate. In addition, the comparative analysis was performed with graphical results using contours of temperature and velocity.


1966 ◽  
Vol 88 (2) ◽  
pp. 179-186 ◽  
Author(s):  
Franz J. Schulenberg

Finned circular tubes have been used exclusively in air-cooled heat exchangers built for the American petroleum and chemical industries. In Europe, however, other tube geometries, in particular, finned elliptical tubes, have been used with great success. In this paper, the theory of the finned elliptical tube and its application in air-cooled heat exchangers are discussed. Finned circular and elliptical tubes are compared; it is shown that the developed heat transfer surface alone is not a sufficient criterion for predicting the performance of an air-cooled fin-tube heat exchanger.


Author(s):  
Jieun Hwang ◽  
Keumnam Cho

Heat exchanger experiences frost on its surface when it operates below 0°C under heating condition of the heat pump. Since frost blocks air flow through the fin tube heat exchanger, it increases air-side pressure drop and deteriorates heat transfer rate of the heat exchanger. Prediction of the frost profiles on the heat exchanger is needed to minimize the unfavorable effect on the heat exchanger by frost. The present study predicts non-uniform frost distribution on the surface of fin-tube heat exchanger and shows its accuracy by comparing with measured profiles. Fin and tube heat exchanger for heat pump was considered for the frost prediction under practical refrigerant and air conditions. Non-uniform frost pattern was predicted by using segment by segment method of the heat exchanger. Heat transfer rate and exit temperature of air and refrigerant for each segment were calculated by applying ε-NTU method. Air volume flow rate in the front of the heat exchanger was decreased as frost goes on. It was utilized for the prediction of the frost formation. Numerically predicted results were compared with measured local data. They agreed within ±10.4% under the ISO 5151 condition.


2013 ◽  
Vol 389 ◽  
pp. 1035-1040 ◽  
Author(s):  
Cong Dong ◽  
Ya Ping Chen ◽  
Jia Feng Wu ◽  
Rui Bing Cao

The circumferential overlap trisection helical baffle shell-and-tube heat exchanger (cothSTHX) is a modification one based on the quadrant helical baffle one to improve the heat transfer performance. The model of cothSTHX has 34 tubes and 3 rods with tube layout of equilateral triangle and a baffle inclined angle of 20°, and the numerical simulation of flow and thermal performances was conducted using the commercial CFD software FLUENT. The distributions of temperature, pressure and velocity, and temperature, pressure or velocity nephograms with superimposed velocity vectors for special slices can provide access to important implicit information in the simulation results. The Dean vortex secondary flow, which is one of the key mechanisms of enhancing heat transfer in heat exchangers, is clearly depicted, and it shows that the fluid in spiral channel flows outward under the centrifugal force, then flows back to the axis under radial differential pressure, thus a single vortex is formed in each baffle pitch cycle. The unfolded concentric hexagonal slices are designed to make up for the defect that the shortcut leakage flow in the V-notch zone of the adjacent baffles could not be depicted along the longitudinal slices. Moreover, the shortcut leakage flow is restricted with the damper effect of the structure that a row of tubes in the circumferential overlap area of adjacent baffles.


Author(s):  
Sun-Joon Byun ◽  
Sang-Jae Lee ◽  
Jae-Min Cha ◽  
Zhen-Huan Wang ◽  
Young-Chul Kwon

This study presents the comparison of heat transfer capacity and pressure drop characteristics between a basic fin-tube heat exchanger and a modified heat exchanger with the structural change of branch tubes and coiled turbulators. All experiments were carried out using an air-enthalpy type calorimeter based on the method described in ASHRAE standards, under heat exchanger experimental conditions. 14 different kinds of heat exchangers were used for the experiment. Cooling and heating capacities of the turbulator heat exchanger were excellent, compared to the basic one. As the insertion ratio of the coiled turbulator and the number of row increased, the heat transfer performance increased. However, the capacity per unit area was more effective in 4 rows than 6 rows, and the cooling performance of the 6 row turbulator heat exchanger (100% turbulator insert ratio) was down to about 6% than that of 4 row one. As the water flow rate and the turbulator insertion ratio increased, the pressure drop of the water side increased. This trend was more pronounced in 6 rows. In the cooling condition, the pressure drop on the air side was slightly increased due to the generation of condensed water, but was insignificant under the heating condition. The power consumption of the pump was more affected by the water flow rate than the coiled turbulator. The equivalent hydraulic diameter of a tube by the turbulator was reduced and then the heat transfer performance was improved. Thus, the tube diameter was smaller, the heat flux was better.


2010 ◽  
Vol 24 (4) ◽  
pp. 961-969 ◽  
Author(s):  
Sung-Jool Kim ◽  
Ho-Jin Choi ◽  
Man-Yeong Ha ◽  
Seok-Ro Kim ◽  
Seon-Wook Bang