scholarly journals Basic Measurement of Air Flow in the Working Environment

2021 ◽  
Author(s):  
Peter Hrabovský ◽  
Zuzana Kolková ◽  
Jozef Matúšov ◽  
Pavol Belány
2019 ◽  
Vol 11 (3) ◽  
pp. 168781401982928 ◽  
Author(s):  
Hengqing Ge ◽  
Guang Xu ◽  
Jinxin Huang ◽  
Xiaoping Ma

A reliable ventilation system is essential for maintaining a comfortable working environment and ensuring safety production in an underground coal mine. The automated fan switchover technique was developed for changing the main fan for maintenance with lower air flow volatility of underground mine in the switchover process. This article established the optimization model in the main fans switchover process, used the improved particle swarm optimization algorithm to solve the model, and achieved minimum air flow volatility in the fans switchover process. Compared to previous studies, computer simulations have shown that the proposed algorithm can effectively find the global optimal solution with less initial parameters and achieved lower air flow volatility in underground mine. The particle swarm optimization solution, searching diversity, prevents it from confining to local optimal solutions and enhances convergence. The reasonable step length is beneficial to reduce the air flow volatility and main fans switchover time. The air flow volatility is larger comparatively when some doors are nearly open or closed fully at the start–stop phase of the switchover process. A case application in a China’s domestic coal mine shows that the air flow volatility of the underground mine in the main fans switchover process is no more than 0.4%.


1974 ◽  
Vol 30 (1) ◽  
pp. 32-41 ◽  
Author(s):  
E. J. Butler ◽  
B. J. Egan
Keyword(s):  

2013 ◽  
Vol 75 (08/09) ◽  
Author(s):  
FS Then ◽  
T Luck ◽  
M Luppa ◽  
M Thinschmidt ◽  
S Deckert ◽  
...  

Author(s):  
Somesh Raju ◽  
Rina Kumari ◽  
Sunita Tiwari ◽  
NS Verma

Background: Interarm systolic blood pressure difference more than 10 mm of Hg is predictor of cardiovascular and metabolic risk. Despite of sufficient physical activity there is high prevalence of obesity in police personal because of stressful working environment. No studies have addressed the significance of interarm pressure difference among them. Therefore, the present study conducted to access the relation of interarm blood pressure difference with obesity in police personnel. Aims and Objective: To estimate the interarm pressure difference in police personal to see its association with their obesity. Material and Method: This cross-sectional observational study done on 245 police workers in PAC, Sitapur, India. Subjects having more than ten years of working experience were included in study. Anthropometric measurements of subject recorded by following standard protocol. Measurement of systolic pressure in both arm recorded simultaneously by mercury sphygmomanometer. Available data analyze and expressed in percentage, mean with SD and chi square test to see the significance of association. Results: According to anthropometric results of subjects 77.14 prcent subjects were having generalised obesity and 82.04 percent of subjects having abdominal obesity. 34.29 percent of subjects showed abnormally high (?10 mmHg) inter-arm systolic blood pressure difference. Both type of obesity showed positive association with blood sugar level but no association with interarm pressure difference. Conclusion: Interarm blood pressure difference is greater in individual having obesity or prolong duration of service. Such subjects are more susceptible to develop coronary artery disease or peripheral arterial disease in future. Early screening can help to detect the vascular events likely to occur in the future Keywords: Body mass index, Waist circumference, Interarm pressure difference, Random blood sugar


Sign in / Sign up

Export Citation Format

Share Document