Three-dimensional step–height measurement using sinusoidal wavelength scanning interferometer with four-step phase-shift method

2014 ◽  
Vol 53 (8) ◽  
pp. 084110 ◽  
Author(s):  
Samuel Choi ◽  
Shouhei Takahashi ◽  
Osami Sasaki ◽  
Takamasa Suzuki
Geophysics ◽  
1984 ◽  
Vol 49 (2) ◽  
pp. 124-131 ◽  
Author(s):  
Jeno Gazdag ◽  
Piero Sguazzero

Under the horizontally layered velocity assumption, migration is defined by a set of independent ordinary differential equations in the wavenumber‐frequency domain. The wave components are extrapolated downward by rotating their phases. This paper shows that one can generalize the concepts of the phase‐shift method to media having lateral velocity variations. The wave extrapolation procedure consists of two steps. In the first step, the wave field is extrapolated by the phase‐shift method using ℓ laterally uniform velocity fields. The intermediate result is ℓ reference wave fields. In the second step, the actual wave field is computed by interpolation from the reference wave fields. The phase shift plus interpolation (PSPI) method is unconditionally stable and lends itself conveniently to migration of three‐dimensional data. The performance of the methods is demonstrated on synthetic examples. The PSPI migration results are then compared with those obtained from a finite‐difference method.


1986 ◽  
Author(s):  
Mickey Edwards ◽  
Chris Hsiung ◽  
David Kessler ◽  
Dan Kosloff ◽  
Moshe Reshef

2020 ◽  
Author(s):  
Taku Sakamoto ◽  
Ichiro Oda ◽  
Takuma Okamura ◽  
Hourin Cho ◽  
Satoru Nonaka ◽  
...  

Abstract Accurate measurement of the distance between any two points under endoscopic examination of the gastrointestinal tract is difficult due to the fisheye lens currently used on endoscopes. To overcome this issue, we developed a three-dimensional visual inspection system that incorporates a phase-shift method for direct measurement of a three-dimensional shape. Projection of a striped pattern is used to enable three-dimensional renderings of a surface using an industrial camera. We evaluated the accuracy of measurement relative to that of reference measurements obtained using a measurement microscope, for three-dimensional shapes on a plane and curved surface. For 60 regions of interests, with various configurations of the reference locations relative to the camera, the measurement error for our system was <0.1 mm on the plane grid and <0.5 mm on the curved surface. The accuracy of our novel three-dimensional visual inspection system could improve determination of the size of lesions with different shapes, flat or depressed, regardless of the curved surface of the gastrointestinal tract.


2007 ◽  
Vol 279 (1) ◽  
pp. 13-19 ◽  
Author(s):  
Satish Kumar Dubey ◽  
Dalip Singh Mehta ◽  
Amitava Roy ◽  
Chandra Shakher

2003 ◽  
Vol 15 (02) ◽  
pp. 61-67 ◽  
Author(s):  
MENG-HSIANG YANG ◽  
K. N. HUANG ◽  
C. F. HUANG ◽  
S. S. HUANG ◽  
M. S. YOUNG

A highly accurate Binary Amplitude-Shift-Keyed (BASK) ultrasonic tremor measurement system for use in isothermal air is developed. In this paper, we present a simple but efficient algorithm based upon phase shifts generated by three ultrasonic waves of different frequencies. By the proposed method, we can conduct larger range measurement than the phase-shift method and also get higher accuracy compared with the time-of-flight (TOF) method. Our microcomputer-based system includes two important parts. One of which is BASK modulation signal generator. The other is a phase meter designed to record and compute the phase shifts of the three different frequencies and the result motion is then sent to either an LCD for display or a PC for calibration. Experiments are done in the laboratory using BASK modulation for the frequencies of 200 Hz and 1 kHz with a 40 kHz carrier. The measurement accuracy of this measurement system in the reported experiments is within +/- 0.98 mm. The main advantages of this ultrasonic tremor measurement system are high resolution, narrow bandwidth requirement, low cost, and easy to be implemented.


2017 ◽  
Vol 40 (13) ◽  
pp. 3690-3695 ◽  
Author(s):  
Wei Wei ◽  
Han-miao Cheng ◽  
Fan Li ◽  
Deng-ping Tang ◽  
Shui-bin Xia

When sampling analog signal, the electronic transformer generally produces a fixed phase error that will compromise the measurement accuracy and require a phase shift method for correction. In this paper, we propose a digital phase shift method based on least squares fitting algorithm and derive the recursion formula of digital phase shift. The simulation has also been done to analysis its performance. The result shows that the method has high phase shift resolution and precision. By applying the method to an electronic transformer based on Rogowski coil, we have experimentally verified the feasibility and validity of the method.


Sign in / Sign up

Export Citation Format

Share Document