scholarly journals Strategies for fast and low-dose laboratory-based phase contrast tomography for microstructural scaffold analysis in tissue engineering

2016 ◽  
Author(s):  
Charlotte K. Hagen ◽  
Panagiotis Maghsoudlou ◽  
Giorgia Totonelli ◽  
Paul C. Diemoz ◽  
Marco Endrizzi ◽  
...  
2014 ◽  
Vol 41 (7) ◽  
pp. 070701 ◽  
Author(s):  
C. K. Hagen ◽  
P. R. T. Munro ◽  
M. Endrizzi ◽  
P. C. Diemoz ◽  
A. Olivo

2016 ◽  
Author(s):  
Anna Zamir ◽  
Charlotte K. Hagen ◽  
Paul C. Diemoz ◽  
Marco Endrizzi ◽  
Fabio A. Vittoria ◽  
...  

Author(s):  
John P. Langmore ◽  
Brian D. Athey

Although electron diffraction indicates better than 0.3nm preservation of biological structure in vitreous ice, the imaging of molecules in ice is limited by low contrast. Thus, low-dose images of frozen-hydrated molecules have significantly more noise than images of air-dried or negatively-stained molecules. We have addressed the question of the origins of this loss of contrast. One unavoidable effect is the reduction in scattering contrast between a molecule and the background. In effect, the difference in scattering power between a molecule and its background is 2-5 times less in a layer of ice than in vacuum or negative stain. A second, previously unrecognized, effect is the large, incoherent background of inelastic scattering from the ice. This background reduces both scattering and phase contrast by an additional factor of about 3, as shown in this paper. We have used energy filtration on the Zeiss EM902 in order to eliminate this second effect, and also increase scattering contrast in bright-field and dark-field.


Author(s):  
E.T. O’Toole ◽  
G.P. Wray ◽  
J.R. Kremer ◽  
J.R. Mcintosh

Ultrarapid freezing and cryomicroscopy of frozen hydrated material makes it possible to visualize samples that have never been exposed to chemical fixatives, dehydration, or stains. In principle, freezing and cryoimaging methods avoid artifacts associated with chemical fixation and processing and allow one to visualize the specimen in a condition that is close to its native state. Here we describe a way to use a high voltage electron microscope (HVEM) for the cryoimaging of frozen hydrated PTK1 cells.PTK1 cells were cultured on formvar-coated, carbon stabilized gold grids. After three days in culture, the grids were removed from the culture medium and blotted in a humidity chamber at 35° C. In some instances, the grids were rinsed briefly in 0.16 M ammonium acetate buffer (pH 7.2) prior to blotting. After blotting, the grids were transferred to a plunging apparatus and plunged into liquid ethane held directly above its freezing point. The plunging apparatus consists of a vertical slide rail that guides the fall of a mounted pair of forceps that clamp the specimen. The forceps are surrounded by a plexiglass humidity chamber mounted over a dewar of liquid nitrogen containing an ethane chamber. After freezing, the samples were transferred to liquid nitrogen and viewed in a JEOL JEM 1000 equipped with a top entry cold stage designed and built by Mr. George Wray (Univ. Colorado). The samples were routinely exposed to electron doses of 1 e/Å2/sec, and viewed at a temperature of −150° C. A GATAN video system was used to enhance contrast and to estimate the correct amount of underfocus needed to obtain phase contrast at various magnifications. Low dose micrographs were taken using two second exposures of Kodak 4463 film. The state of the solid water in the specimen was determined by diffraction using a 30/μm field limiting aperture and a camera length of 1 meter.


2016 ◽  
Vol 7 (2) ◽  
pp. 381 ◽  
Author(s):  
Lukas B. Gromann ◽  
Dirk Bequé ◽  
Kai Scherer ◽  
Konstantin Willer ◽  
Lorenz Birnbacher ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document