Compact multilaser TDLAS for trace gas flux measurements based on a micrometeorological technique

Author(s):  
Robert Kormann ◽  
Horst Fischer ◽  
Frank G. Wienhold
Keyword(s):  
Gas Flux ◽  
2001 ◽  
Vol 28 (16) ◽  
pp. 3139-3142 ◽  
Author(s):  
H. J. I. Rinne ◽  
A. B. Guenther ◽  
C. Warneke ◽  
J. A. de Gouw ◽  
S. L. Luxembourg

2019 ◽  
Author(s):  
Lukas Siebicke ◽  
Anas Emad

Abstract. Micrometeorological methods to quantify fluxes of atmospheric constituents are key to understanding and managing the impact of land surface sources and sinks on air quality and atmospheric composition. Important greenhouse gases are water vapor, carbon dioxide, methane, and nitrous oxide. Further important atmospheric constituents are aerosols which impact air quality and cloud formation, and volatile organic compounds. Many atmospheric constituents therefore critically affect the health of ecosystems, and humans as well as climate. The micrometeorological eddy covariance (EC) method has evolved as the method-of-choice for CO2 and water vapor flux measurements using fast-response gas analyzers. While the EC method has also been used to measure other atmospheric constituents including methane, nitrous oxide, and ozone, the often relatively small fluxes of these constituents over ecosystems are much more challenging to measure by eddy covariance than CO2 and water vapor fluxes. For many further atmospheric constituents, eddy covariance is not an option due to the lack of sufficiently accurate and fast-response gas analyzers. Therefore, alternative flux measurement methods are required for the observation of atmospheric constituent fluxes for which no fast-response gas analyzers exist or which require more accurate measurements. True eddy accumulation (TEA) is a direct flux measurement technique capable of using slow-response gas analyzers. Unlike its more frequently used derivative, known as the relaxed eddy accumulation (REA) method, TEA does not require the use of proxies and is therefore superior to the indirect REA method. The true eddy accumulation method is by design ideally suited for measuring a wide range of trace gases and other conserved constituents transported with the air. This is because TEA obtains whole air samples and is, in combination with constituent-specific fast or slow analyzers, a universal method for conserved scalars. Despite the recognized value of the method, true eddy accumulation flux measurements remained very challenging to perform as they require fast and dynamic modulation of the air sampling mass flow rate proportional to the magnitude of the instantaneous vertical wind velocity. Appropriate techniques for dynamic mass flow control have long been unavailable, preventing the unlocking of the TEA method's potential for more than 40 years. Recently, a new dynamic and accurate mass flow controller which can resolve turbulence at a frequency of 10 Hz and higher has been developed by the author. This study presents the proof-of-concept that practical true eddy accumulation trace gas flux measurements are possible today using dynamic mass flow control, advanced real-time processing of wind measurements, and fully automatic gas handling. We describe setup and methods of the TEA and EC reference flux measurements. The experiment was conducted over grassland and comprised seven days of continuous flux measurements at 30-min flux integration intervals. The results show that fluxes obtained by TEA compared favourably to EC reference flux measurements with coefficients of determination of up to 86 % and a slope of 0.98. We present a quantitative analysis of uncertainties of the mass flow control system, the gas analyzer and gas handling system and their impact on trace gas flux uncertainty, the impact of different approaches to coordinate rotation and uncertainties of vertical wind velocity measurements. Challenges of TEA are highlighted and solutions presented. The current results are put into context of previous works. Finally, based on the current successful proof-of-concept, we suggest specific improvements towards long-term and reliable true eddy accumulation flux measurements.


2019 ◽  
Vol 12 (8) ◽  
pp. 4393-4420 ◽  
Author(s):  
Lukas Siebicke ◽  
Anas Emad

Abstract. Micrometeorological methods to quantify fluxes of atmospheric constituents are key to understanding and managing the impact of land surface sources and sinks on air quality and atmospheric composition. Important greenhouse gases are water vapor, carbon dioxide, methane, and nitrous oxide. Further important atmospheric constituents are aerosols, which impact air quality and cloud formation, and volatile organic compounds. Many atmospheric constituents therefore critically affect the health of ecosystems and humans, as well as climate. The micrometeorological eddy covariance (EC) method has evolved as the method of choice for CO2 and water vapor flux measurements using fast-response gas analyzers. While the EC method has also been used to measure other atmospheric constituents including methane, nitrous oxide, and ozone, the often relatively small fluxes of these constituents over ecosystems are much more challenging to measure using eddy covariance than CO2 and water vapor fluxes. For many further atmospheric constituents, eddy covariance is not an option due to the lack of sufficiently accurate and fast-response gas analyzers. Therefore, alternative flux measurement methods are required for the observation of atmospheric constituent fluxes for which no fast-response gas analyzers exist or which require more accurate measurements. True eddy accumulation (TEA) is a direct flux measurement technique capable of using slow-response gas analyzers. Unlike its more frequently used derivative, known as the relaxed eddy accumulation (REA) method, TEA does not require the use of proxies and is therefore superior to the indirect REA method. The true eddy accumulation method is by design ideally suited for measuring a wide range of trace gases and other conserved constituents transported with the air. This is because TEA obtains whole air samples and is, in combination with constituent-specific fast or slow analyzers, a universal method for conserved scalars. Despite the recognized value of the method, true eddy accumulation flux measurements remain very challenging to perform as they require fast and dynamic modulation of the air sampling mass flow rate proportional to the magnitude of the instantaneous vertical wind velocity. Appropriate techniques for dynamic mass flow control have long been unavailable, preventing the unlocking of the TEA method's potential for more than 40 years. Recently, a new dynamic and accurate mass flow controller which can resolve turbulence at a frequency of 10 Hz and higher has been developed by the first author. This study presents the proof of concept that practical true eddy accumulation trace gas flux measurements are possible today using dynamic mass flow control, advanced real-time processing of wind measurements, and fully automatic gas handling. We describe setup and methods of the TEA and EC reference flux measurements. The experiment was conducted over grassland and comprised 7 d of continuous flux measurements at 30 min flux integration intervals. The results show that fluxes obtained by TEA compared favorably to EC reference flux measurements, with coefficients of determination of up to 86 % and a slope of 0.98. We present a quantitative analysis of uncertainties of the mass flow control system, the gas analyzer, and gas handling system and their impact on trace gas flux uncertainty, the impact of different approaches to coordinate rotation, and uncertainties of vertical wind velocity measurements. Challenges of TEA are highlighted and solutions presented. The current results are put into the context of previous works. Finally, based on the current successful proof of concept, we suggest specific improvements towards long-term and reliable true eddy accumulation flux measurements.


2021 ◽  
Vol 14 (6) ◽  
pp. 4445-4460
Author(s):  
Lukas Kohl ◽  
Markku Koskinen ◽  
Tatu Polvinen ◽  
Salla Tenhovirta ◽  
Kaisa Rissanen ◽  
...  

Abstract. Plant shoots can act as sources or sinks of trace gases including methane and nitrous oxide. Accurate measurements of these trace gas fluxes require enclosing of shoots in closed non-steady-state chambers. Due to plant physiological activity, this type of enclosure, however, leads to CO2 depletion in the enclosed air volume, condensation of transpired water, and warming of the enclosures exposed to sunlight, all of which may bias the flux measurements. Here, we present ShoTGa-FluMS (SHOot Trace Gas FLUx Measurement System), a novel measurement system designed for continuous and automated measurements of trace gas and volatile organic compound (VOC) fluxes from plant shoots. The system uses transparent shoot enclosures equipped with Peltier cooling elements and automatically replaces fixated CO2 and removes transpired water from the enclosure. The system is designed for measuring trace gas fluxes over extended periods, capturing diurnal and seasonal variations, and linking trace gas exchange to plant physiological functioning and environmental drivers. Initial measurements show daytime CH4 emissions of two pine shoots of 0.056 and 0.089 nmol per gram of foliage dry weight (d.w.) per hour or 7.80 and 13.1 nmolm-2h-1. Simultaneously measured CO2 uptake rates were 9.2 and 7.6 mmolm-2h-1, and transpiration rates were 1.24 and 0.90 molm-2h-1. Concurrent measurement of VOC emissions demonstrated that potential effects of spectral interferences on CH4 flux measurements were at least 10-fold smaller than the measured CH4 fluxes. Overall, this new system solves multiple technical problems that have so far prevented automated plant shoot trace gas flux measurements and holds the potential for providing important new insights into the role of plant foliage in the global CH4 and N2O cycles.


2008 ◽  
Vol 152 (3) ◽  
pp. 630-635 ◽  
Author(s):  
J. Rinne ◽  
T. Douffet ◽  
Y. Prigent ◽  
P. Durand

2021 ◽  
Author(s):  
Lukas Kohl ◽  
Markku Koskinen ◽  
Tatu Polvinen ◽  
Salla Tenhovirta ◽  
Kaisa Rissanen ◽  
...  

Abstract. Plant shoots can act as sources or sinks of trace gases including methane and nitrous oxide. Accurate measurementsof these trace gas fluxes require enclosing of shoots in closed non-steady state chambers. Due to plant physiological activity, this type of enclosures, however, lead to CO2 depletion in the enclosed air volume, condensation of transpired water, and warmingof the enclosures exposed to sunlight, all of which may bias the flux measurements. Here, we present PlasTraGAS, ab novel measurement system designed for continuous and automated measurements of trace gas and volatile organic compound (VOC) fluxes from plant shoots. The system uses transparent shoot enclosures equipped with Peltier cooling elements and automatically replaces fixated CO2 and removes transpired water from the enclosure. The system is designed for measuring trace gasfluxes over extended periods, capturing diurnal and seasonal variations and linking trace gas exchange to plant physiologicalfunctioning and environmental drivers. Initial measurements show daytime CH4 emissions two pine shoots of 0.056 and 0.089 nmol g−1 foliage d.w.h−1or 7.80 and 13.1 nmol m−2 h−1. Simultaneously measured CO2 uptake rates were 9.2 and 7.6 mmol m−2 sec−1 and transpiration rates of 1.24 and 0.90 mol m−2 h−1. Concurrent measurement of VOC emissionsdemonstrated that potential effects of spectral interferences on CH4 flux measurements were at least ten-fold smaller than themeasured CH4 fluxes. Overall, this new system solves multiple technical problems that so far prevented automated plant shoottrace gas flux measurements, and holds the potential for providing important new insights into the role of plant foliage in the global CH4 and N2O cycles.


Sign in / Sign up

Export Citation Format

Share Document