scholarly journals True eddy accumulation trace gas flux measurements: proof-of-concept

2019 ◽  
Author(s):  
Lukas Siebicke ◽  
Anas Emad

Abstract. Micrometeorological methods to quantify fluxes of atmospheric constituents are key to understanding and managing the impact of land surface sources and sinks on air quality and atmospheric composition. Important greenhouse gases are water vapor, carbon dioxide, methane, and nitrous oxide. Further important atmospheric constituents are aerosols which impact air quality and cloud formation, and volatile organic compounds. Many atmospheric constituents therefore critically affect the health of ecosystems, and humans as well as climate. The micrometeorological eddy covariance (EC) method has evolved as the method-of-choice for CO2 and water vapor flux measurements using fast-response gas analyzers. While the EC method has also been used to measure other atmospheric constituents including methane, nitrous oxide, and ozone, the often relatively small fluxes of these constituents over ecosystems are much more challenging to measure by eddy covariance than CO2 and water vapor fluxes. For many further atmospheric constituents, eddy covariance is not an option due to the lack of sufficiently accurate and fast-response gas analyzers. Therefore, alternative flux measurement methods are required for the observation of atmospheric constituent fluxes for which no fast-response gas analyzers exist or which require more accurate measurements. True eddy accumulation (TEA) is a direct flux measurement technique capable of using slow-response gas analyzers. Unlike its more frequently used derivative, known as the relaxed eddy accumulation (REA) method, TEA does not require the use of proxies and is therefore superior to the indirect REA method. The true eddy accumulation method is by design ideally suited for measuring a wide range of trace gases and other conserved constituents transported with the air. This is because TEA obtains whole air samples and is, in combination with constituent-specific fast or slow analyzers, a universal method for conserved scalars. Despite the recognized value of the method, true eddy accumulation flux measurements remained very challenging to perform as they require fast and dynamic modulation of the air sampling mass flow rate proportional to the magnitude of the instantaneous vertical wind velocity. Appropriate techniques for dynamic mass flow control have long been unavailable, preventing the unlocking of the TEA method's potential for more than 40 years. Recently, a new dynamic and accurate mass flow controller which can resolve turbulence at a frequency of 10 Hz and higher has been developed by the author. This study presents the proof-of-concept that practical true eddy accumulation trace gas flux measurements are possible today using dynamic mass flow control, advanced real-time processing of wind measurements, and fully automatic gas handling. We describe setup and methods of the TEA and EC reference flux measurements. The experiment was conducted over grassland and comprised seven days of continuous flux measurements at 30-min flux integration intervals. The results show that fluxes obtained by TEA compared favourably to EC reference flux measurements with coefficients of determination of up to 86 % and a slope of 0.98. We present a quantitative analysis of uncertainties of the mass flow control system, the gas analyzer and gas handling system and their impact on trace gas flux uncertainty, the impact of different approaches to coordinate rotation and uncertainties of vertical wind velocity measurements. Challenges of TEA are highlighted and solutions presented. The current results are put into context of previous works. Finally, based on the current successful proof-of-concept, we suggest specific improvements towards long-term and reliable true eddy accumulation flux measurements.

2019 ◽  
Vol 12 (8) ◽  
pp. 4393-4420 ◽  
Author(s):  
Lukas Siebicke ◽  
Anas Emad

Abstract. Micrometeorological methods to quantify fluxes of atmospheric constituents are key to understanding and managing the impact of land surface sources and sinks on air quality and atmospheric composition. Important greenhouse gases are water vapor, carbon dioxide, methane, and nitrous oxide. Further important atmospheric constituents are aerosols, which impact air quality and cloud formation, and volatile organic compounds. Many atmospheric constituents therefore critically affect the health of ecosystems and humans, as well as climate. The micrometeorological eddy covariance (EC) method has evolved as the method of choice for CO2 and water vapor flux measurements using fast-response gas analyzers. While the EC method has also been used to measure other atmospheric constituents including methane, nitrous oxide, and ozone, the often relatively small fluxes of these constituents over ecosystems are much more challenging to measure using eddy covariance than CO2 and water vapor fluxes. For many further atmospheric constituents, eddy covariance is not an option due to the lack of sufficiently accurate and fast-response gas analyzers. Therefore, alternative flux measurement methods are required for the observation of atmospheric constituent fluxes for which no fast-response gas analyzers exist or which require more accurate measurements. True eddy accumulation (TEA) is a direct flux measurement technique capable of using slow-response gas analyzers. Unlike its more frequently used derivative, known as the relaxed eddy accumulation (REA) method, TEA does not require the use of proxies and is therefore superior to the indirect REA method. The true eddy accumulation method is by design ideally suited for measuring a wide range of trace gases and other conserved constituents transported with the air. This is because TEA obtains whole air samples and is, in combination with constituent-specific fast or slow analyzers, a universal method for conserved scalars. Despite the recognized value of the method, true eddy accumulation flux measurements remain very challenging to perform as they require fast and dynamic modulation of the air sampling mass flow rate proportional to the magnitude of the instantaneous vertical wind velocity. Appropriate techniques for dynamic mass flow control have long been unavailable, preventing the unlocking of the TEA method's potential for more than 40 years. Recently, a new dynamic and accurate mass flow controller which can resolve turbulence at a frequency of 10 Hz and higher has been developed by the first author. This study presents the proof of concept that practical true eddy accumulation trace gas flux measurements are possible today using dynamic mass flow control, advanced real-time processing of wind measurements, and fully automatic gas handling. We describe setup and methods of the TEA and EC reference flux measurements. The experiment was conducted over grassland and comprised 7 d of continuous flux measurements at 30 min flux integration intervals. The results show that fluxes obtained by TEA compared favorably to EC reference flux measurements, with coefficients of determination of up to 86 % and a slope of 0.98. We present a quantitative analysis of uncertainties of the mass flow control system, the gas analyzer, and gas handling system and their impact on trace gas flux uncertainty, the impact of different approaches to coordinate rotation, and uncertainties of vertical wind velocity measurements. Challenges of TEA are highlighted and solutions presented. The current results are put into the context of previous works. Finally, based on the current successful proof of concept, we suggest specific improvements towards long-term and reliable true eddy accumulation flux measurements.


2001 ◽  
Vol 28 (16) ◽  
pp. 3139-3142 ◽  
Author(s):  
H. J. I. Rinne ◽  
A. B. Guenther ◽  
C. Warneke ◽  
J. A. de Gouw ◽  
S. L. Luxembourg

2012 ◽  
Vol 5 (1) ◽  
pp. 351-384 ◽  
Author(s):  
R. V. Hiller ◽  
C. Zellweger ◽  
A. Knohl ◽  
W. Eugster

Abstract. Recently, instruments became available on the market that provide the possibility to perform eddy covariance flux measurements of CH4 and many other trace gases, including the traditional CO2 and H2O. Most of these instruments employ laser spectroscopy, where a cross-sensitivity to H2O is frequently observed leading to an increased dilution effect. Additionally, sorption processes at the intake tube walls modify and delay the observed H2O signal in closed-path systems more strongly than the signal of the sampled trace gas. Thereby, a phase shift between the trace gas and H2O fluctuations is introduced that dampens the H2O flux observed in the sampling cell. For instruments that do not provide direct H2O measurement in the sampling cell, transfer functions from externally measured H2O fluxes are needed to estimate the effect of H2O on trace gas flux measurements. The effects of cross-sensitivity and the damping are shown for an eddy covariance setup with the Fast Greenhouse Gas Analyzer (FGGA, Los Gatos Research Inc.) that measures CO2, CH4, and H2O fluxes. This instrument is technically identical with the Fast Methane Analyzer (FMA, Los Gatos Research Inc.) that does not measure H2O concentrations. Hence, we used measurements from a FGGA to derive a modified correction for the FMA accounting for dilution as well as phase shift effects in our instrumental setup. With our specific setup for eddy covariance flux measurements, the cross-sensitivity counteracts the damping effects, which compensate each other. Hence, the new correction only deviates very slightly from the traditional Webb, Pearman, and Leuning density correction, which is calculated from separate measurements of the atmospheric water vapor flux.


2008 ◽  
Vol 152 (3) ◽  
pp. 630-635 ◽  
Author(s):  
J. Rinne ◽  
T. Douffet ◽  
Y. Prigent ◽  
P. Durand

2019 ◽  
Vol 16 (16) ◽  
pp. 3113-3131 ◽  
Author(s):  
Mathias Göckede ◽  
Fanny Kittler ◽  
Carsten Schaller

Abstract. Methane flux measurements by the eddy-covariance technique are subject to large uncertainties, particularly linked to the partly highly intermittent nature of methane emissions. Outbursts of high methane emissions, termed event fluxes, hold the potential to introduce systematic biases into derived methane budgets, since under such conditions the assumption of stationarity of the flow is violated. In this study, we investigate the net impact of this effect by comparing eddy-covariance fluxes against a wavelet-derived reference that is not negatively influenced by non-stationarity. Our results demonstrate that methane emission events influenced 3 %–4 % of the flux measurements and did not lead to systematic biases in methane budgets for the analyzed summer season; however, the presence of events substantially increased uncertainties in short-term flux rates. The wavelet results provided an excellent reference to evaluate the performance of three different gap-filling approaches for eddy-covariance methane fluxes, and we show that none of them could reproduce the range of observed flux rates. The integrated performance of the gap-filling methods for the longer-term dataset varied between the two eddy-covariance towers involved in this study, and we show that gap-filling remains a large source of uncertainty linked to limited insights into the mechanisms governing the short-term variability in methane emissions. With the capability for broadening our observational methane flux database to a wider range of conditions, including the direct resolution of short-term variability on the order of minutes, wavelet-derived fluxes hold the potential to generate new insight into methane exchange processes with the atmosphere and therefore also improve our understanding of the underlying processes.


2010 ◽  
Vol 3 (4) ◽  
pp. 2961-2993 ◽  
Author(s):  
B. Tuzson ◽  
R. V. Hiller ◽  
K. Zeyer ◽  
W. Eugster ◽  
A. Neftel ◽  
...  

Abstract. Fast response optical analyzers based on laser absorption spectroscopy are the preferred tools to measure field-scale mixing ratios and fluxes of a range of trace gases. Several state-of-the-art instruments have become commercially available and are gaining in popularity. This paper aims for a critical field evaluation and intercomparison of two compact, cryogen-free and fast response instruments: a quantum cascade laser based absorption spectrometer from Aerodyne Research, Inc., and an off-axis integrated cavity output spectrometer from Los Gatos Research, Inc. In this paper, both analyzers are characterized with respect to precision, accuracy, response time and also their sensitivity to water vapour. The instruments were tested in a field campaign to assess their behaviour under various meteorological conditions. The instrument's suitability for eddy covariance flux measurements was evaluated by applying an artificial flux of CH4 generated above a managed grassland with otherwise very low methane flux. This allowed an independent verification of the flux measurements accuracy, including the overall eddy covariance setup and data treatment. The retrieved fluxes were in good agreement with the known artificial emission flux, which is more than satisfactory, given that the analyzers were attached to separate sonic anemometers placed on individual eddy towers with different data acquisition systems but similar data treatment that are specific to the best practice used by the involved research teams.


Sign in / Sign up

Export Citation Format

Share Document